{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T10:44:59Z","timestamp":1761561899805,"version":"3.44.0"},"reference-count":25,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2014,11,1]],"date-time":"2014-11-01T00:00:00Z","timestamp":1414800000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2014,11,1]],"date-time":"2014-11-01T00:00:00Z","timestamp":1414800000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["ajconline.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The American Journal of Cardiology"],"published-print":{"date-parts":[[2014,11]]},"DOI":"10.1016\/j.amjcard.2014.08.020","type":"journal-article","created":{"date-parts":[[2014,8,27]],"date-time":"2014-08-27T16:46:23Z","timestamp":1409157983000},"page":"1556-1561","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":29,"title":["Insights Into New-Onset Rhythm Conduction Disorders Detected by Multi-Detector Row Computed Tomography After Transcatheter Aortic Valve Implantation"],"prefix":"10.1016","volume":"114","author":[{"given":"Spyridon","family":"Katsanos","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philippe","family":"van Rosendael","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vasileios","family":"Kamperidis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frank","family":"van der Kley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emer","family":"Joyce","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philippe","family":"Debonnaire","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ioannis","family":"Karalis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeroen J.","family":"Bax","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nina Ajmone","family":"Marsan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Victoria","family":"Delgado","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.amjcard.2014.08.020_bib1","doi-asserted-by":"crossref","first-page":"1599","DOI":"10.1093\/eurheartj\/eht376","article-title":"Clinical implications of new-onset left bundle branch block after transcatheter aortic valve replacement: analysis of the partner experience","volume":"35","author":"Nazif","year":"2014","journal-title":"Eur Heart J"},{"key":"10.1016\/j.amjcard.2014.08.020_bib2","doi-asserted-by":"crossref","first-page":"1743","DOI":"10.1016\/j.jacc.2012.07.035","article-title":"Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve","volume":"60","author":"Urena","year":"2012","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.amjcard.2014.08.020_bib3","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1016\/j.jcin.2012.03.004","article-title":"Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings","volume":"5","author":"Bagur","year":"2012","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.amjcard.2014.08.020_bib4","doi-asserted-by":"crossref","first-page":"1686","DOI":"10.1056\/NEJMoa1200384","article-title":"Two-year outcomes after transcatheter or surgical aortic-valve replacement","volume":"366","author":"Kodali","year":"2012","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.amjcard.2014.08.020_bib5","doi-asserted-by":"crossref","first-page":"1597","DOI":"10.1056\/NEJMoa1008232","article-title":"Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery","volume":"363","author":"Leon","year":"2010","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.amjcard.2014.08.020_bib6","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1056\/NEJMoa1103510","article-title":"Transcatheter versus surgical aortic-valve replacement in high-risk patients","volume":"364","author":"Smith","year":"2011","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.amjcard.2014.08.020_bib7","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1093\/eurheartj\/ehq427","article-title":"One year follow-up of the multi-centre European PARTNER transcatheter heart valve study","volume":"32","author":"Lefevre","year":"2011","journal-title":"Eur Heart J"},{"key":"10.1016\/j.amjcard.2014.08.020_bib8","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1161\/CIRCULATIONAHA.109.907402","article-title":"Thirty-day results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: a European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve","volume":"122","author":"Thomas","year":"2010","journal-title":"Circulation"},{"key":"10.1016\/j.amjcard.2014.08.020_bib9","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1016\/j.jcin.2012.12.128","article-title":"Impact of post-implant SAPIEN XT geometry and position on conduction disturbances, hemodynamic performance, and paravalvular regurgitation","volume":"6","author":"Binder","year":"2013","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.amjcard.2014.08.020_bib10","doi-asserted-by":"crossref","first-page":"1244","DOI":"10.1016\/j.athoracsur.2011.01.059","article-title":"Outcomes after transcatheter aortic valve implantation: transfemoral versus transapical approach","volume":"92","author":"Ewe","year":"2011","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.amjcard.2014.08.020_bib11","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1016\/S0735-1097(85)80335-1","article-title":"Criteria for intraventricular conduction disturbances and pre-excitation. World Health Organizational\/International Society and Federation for Cardiology Task Force Ad Hoc","volume":"5","author":"Willems","year":"1985","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.amjcard.2014.08.020_bib12","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1161\/CIRCULATIONAHA.113.002947","article-title":"Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement","volume":"128","author":"Barbanti","year":"2013","journal-title":"Circulation"},{"key":"10.1016\/j.amjcard.2014.08.020_bib13","doi-asserted-by":"crossref","first-page":"1800","DOI":"10.1016\/j.amjcard.2013.07.049","article-title":"Multidetector row computed tomography parameters associated with paravalvular regurgitation after transcatheter aortic valve implantation","volume":"112","author":"Katsanos","year":"2013","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.amjcard.2014.08.020_bib14","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1161\/CIRCINTERVENTIONS.111.967349","article-title":"Prosthesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root","volume":"5","author":"Blanke","year":"2012","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.amjcard.2014.08.020_bib15","doi-asserted-by":"crossref","first-page":"2069","DOI":"10.1001\/jama.2013.282043","article-title":"Outcomes following transcatheter aortic valve replacement in the united states","volume":"310","author":"Mack","year":"2013","journal-title":"JAMA"},{"key":"10.1016\/j.amjcard.2014.08.020_bib16","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1016\/j.ahj.2009.05.029","article-title":"Electrocardiographic changes and clinical outcomes after transapical aortic valve implantation","volume":"158","author":"Gutierrez","year":"2009","journal-title":"Am Heart J"},{"key":"10.1016\/j.amjcard.2014.08.020_bib17","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/j.amjcard.2013.04.026","article-title":"Comparison of incidence and predictors of left bundle branch block after transcatheter aortic valve implantation using the corevalve versus the edwards valve","volume":"112","author":"Franzoni","year":"2013","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.amjcard.2014.08.020_bib18","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1111\/j.1540-8167.2011.02211.x","article-title":"Risk for permanent pacemaker after transcatheter aortic valve implantation: a comprehensive analysis of the literature","volume":"23","author":"Erkapic","year":"2012","journal-title":"J\u00a0Cardiovasc Electrophysiol"},{"key":"10.1016\/j.amjcard.2014.08.020_bib19","doi-asserted-by":"crossref","first-page":"1473","DOI":"10.1016\/j.amjcard.2010.07.012","article-title":"Incidence and predictors of atrioventricular conduction impairment after transcatheter aortic valve implantation","volume":"106","author":"Roten","year":"2010","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.amjcard.2014.08.020_bib20","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1093\/eurheartj\/ehq339","article-title":"Transcatheter aortic valve implantation: First results from a multi-centre real-world registry","volume":"32","author":"Zahn","year":"2011","journal-title":"Eur Heart J"},{"key":"10.1016\/j.amjcard.2014.08.020_bib21","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.ijcard.2011.03.004","article-title":"Incidence and predictors of left bundle branch block after transcatheter aortic valve implantation","volume":"160","author":"Aktug","year":"2012","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.amjcard.2014.08.020_bib22","doi-asserted-by":"crossref","first-page":"2658","DOI":"10.1016\/j.ijcard.2013.03.030","article-title":"MSCT guided sizing of the Edwards SAPIEN XT TAVI device: impact of different degrees of oversizing on clinical outcome","volume":"168","author":"Leber","year":"2013","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.amjcard.2014.08.020_bib23","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1161\/CIRCIMAGING.113.001153","article-title":"Aortic annular sizing using a novel 3-dimensional echocardiographic method: use and comparison with cardiac computed tomography","volume":"7","author":"Khalique","year":"2014","journal-title":"Circ Cardiovasc Imaging"},{"key":"10.1016\/j.amjcard.2014.08.020_bib24","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1016\/j.amjcard.2011.05.014","article-title":"Evaluation of multislice computed tomography early after transcatheter aortic valve implantation with the Edwards SAPIEN bioprosthesis","volume":"108","author":"Caudron","year":"2011","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.amjcard.2014.08.020_bib25","doi-asserted-by":"crossref","first-page":"1759","DOI":"10.1093\/europace\/eus191","article-title":"Predictors of permanent pacemaker implantation after medtronic corevalve bioprosthesis implantation","volume":"14","author":"Schroeter","year":"2012","journal-title":"Europace"}],"container-title":["The American Journal of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002914914017147?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002914914017147?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T06:27:21Z","timestamp":1757572041000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0002914914017147"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,11]]},"references-count":25,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2014,11]]}},"alternative-id":["S0002914914017147"],"URL":"https:\/\/doi.org\/10.1016\/j.amjcard.2014.08.020","relation":{},"ISSN":["0002-9149"],"issn-type":[{"type":"print","value":"0002-9149"}],"subject":[],"published":{"date-parts":[[2014,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Insights Into New-Onset Rhythm Conduction Disorders Detected by Multi-Detector Row Computed Tomography After Transcatheter Aortic Valve Implantation","name":"articletitle","label":"Article Title"},{"value":"The American Journal of Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.amjcard.2014.08.020","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}