{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,24]],"date-time":"2026-02-24T08:32:28Z","timestamp":1771921948934,"version":"3.50.1"},"reference-count":21,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2015,3,1]],"date-time":"2015-03-01T00:00:00Z","timestamp":1425168000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2015,3,1]],"date-time":"2015-03-01T00:00:00Z","timestamp":1425168000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100005035","name":"Biotronik","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100005035","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100006520","name":"Edwards Lifesciences","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006520","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100006775","name":"GE Healthcare","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006775","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004374","name":"Medtronic","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004374","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100008497","name":"Boston Scientific Corporation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008497","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["ajconline.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The American Journal of Cardiology"],"published-print":{"date-parts":[[2015,3]]},"DOI":"10.1016\/j.amjcard.2014.12.018","type":"journal-article","created":{"date-parts":[[2014,12,19]],"date-time":"2014-12-19T18:29:20Z","timestamp":1419013760000},"page":"664-669","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":12,"title":["Effect of Aortic Regurgitation Following Transcatheter Aortic Valve Implantation on Outcomes"],"prefix":"10.1016","volume":"115","author":[{"given":"See Hooi","family":"Ewe","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manuela","family":"Muratori","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frank","family":"van der Kley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mauro","family":"Pepi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Victoria","family":"Delgado","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gloria","family":"Tamborini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laura","family":"Fusini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arend","family":"de Weger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paola","family":"Gripari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antonio","family":"Bartorelli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeroen J.","family":"Bax","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nina Ajmone","family":"Marsan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.amjcard.2014.12.018_bib1","doi-asserted-by":"crossref","first-page":"1597","DOI":"10.1056\/NEJMoa1008232","article-title":"Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery","volume":"363","author":"Leon","year":"2010","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.amjcard.2014.12.018_bib2","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1161\/CIRCULATIONAHA.110.946533","article-title":"Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis","volume":"123","author":"Tamburino","year":"2011","journal-title":"Circulation"},{"key":"10.1016\/j.amjcard.2014.12.018_bib3","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1093\/eurheartj\/ehq453","article-title":"Percutaneous transarterial aortic valve implantation: what do we know?","volume":"32","author":"Webb","year":"2011","journal-title":"Eur Heart J"},{"key":"10.1016\/j.amjcard.2014.12.018_bib4","doi-asserted-by":"crossref","first-page":"1686","DOI":"10.1056\/NEJMoa1200384","article-title":"Two-year outcomes after transcatheter or surgical aortic-valve replacement","volume":"366","author":"Kodali","year":"2012","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.amjcard.2014.12.018_bib5","doi-asserted-by":"crossref","first-page":"899","DOI":"10.1136\/hrt.2010.217158","article-title":"Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry","volume":"97","author":"Abdel-Wahab","year":"2011","journal-title":"Heart"},{"key":"10.1016\/j.amjcard.2014.12.018_bib6","doi-asserted-by":"crossref","first-page":"2130","DOI":"10.1016\/j.jacc.2011.08.050","article-title":"Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the U.K. TAVI (United Kingdom Transcatheter Aortic Valve Implantation) registry","volume":"58","author":"Moat","year":"2011","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.amjcard.2014.12.018_bib7","doi-asserted-by":"crossref","first-page":"643","DOI":"10.4244\/EIJV6I5A107","article-title":"Multimodality imaging in transcatheter aortic valve implantation: key steps to assess procedural feasibility","volume":"6","author":"Delgado","year":"2010","journal-title":"EuroIntervention"},{"key":"10.1016\/j.amjcard.2014.12.018_bib8","doi-asserted-by":"crossref","first-page":"1463","DOI":"10.1093\/eurheartj\/ehn183","volume":"29","author":"Vahanian","year":"2008","journal-title":"Eur Heart J"},{"key":"10.1016\/j.amjcard.2014.12.018_bib9","doi-asserted-by":"crossref","first-page":"1440","DOI":"10.1016\/j.echo.2005.10.005","article-title":"Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group","volume":"18","author":"Lang","year":"2005","journal-title":"J\u00a0Am Soc Echocardiogr"},{"key":"10.1016\/j.amjcard.2014.12.018_bib10","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1093\/ejechocard\/jen303","article-title":"Echocardiographic assessment of valve stenosis: EAE\/ASE recommendations for clinical practice","volume":"10","author":"Baumgartner","year":"2009","journal-title":"Eur J Echocardiogr"},{"key":"10.1016\/j.amjcard.2014.12.018_bib11","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1016\/0002-9149(86)90771-X","article-title":"Echocardiographic assessment of left ventricular hypertrophy: comparison to necropsy findings","volume":"57","author":"Devereux","year":"1986","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.amjcard.2014.12.018_bib12","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1016\/S0894-7317(03)00335-3","article-title":"Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography","volume":"16","author":"Zoghbi","year":"2003","journal-title":"J\u00a0Am Soc Echocardiogr"},{"key":"10.1016\/j.amjcard.2014.12.018_bib13","doi-asserted-by":"crossref","first-page":"2189","DOI":"10.1093\/eurheartj\/ehr259","article-title":"EAE\/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease","volume":"32","author":"Zamorano","year":"2011","journal-title":"Eur Heart J"},{"key":"10.1016\/j.amjcard.2014.12.018_bib14","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1016\/j.echo.2009.07.013","article-title":"Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves","volume":"22","author":"Zoghbi","year":"2009","journal-title":"J\u00a0Am Soc Echocardiogr"},{"key":"10.1016\/j.amjcard.2014.12.018_bib15","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1093\/eurheartj\/ehq406","article-title":"Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium","volume":"32","author":"Leon","year":"2011","journal-title":"Eur Heart J"},{"key":"10.1016\/j.amjcard.2014.12.018_bib16","doi-asserted-by":"crossref","first-page":"1319","DOI":"10.1161\/CIRCULATIONAHA.110.948877","article-title":"Transcatheter aortic valve implantation: durability of clinical and hemodynamic outcomes beyond 3 years in a large patient cohort","volume":"122","author":"Gurvitch","year":"2010","journal-title":"Circulation"},{"key":"10.1016\/j.amjcard.2014.12.018_bib17","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1016\/j.echo.2010.01.020","article-title":"Immediate and long-term echocardiographic findings after transcatheter aortic valve implantation for the treatment of aortic stenosis: the Cribier-Edwards\/Edwards-Sapien valve experience","volume":"23","author":"Bauer","year":"2010","journal-title":"J\u00a0Am Soc Echocardiogr"},{"key":"10.1016\/j.amjcard.2014.12.018_bib18","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1016\/j.jacc.2012.08.1039","article-title":"Paravalvular leak after transcatheter aortic valve replacement the new Achilles' heel? A comprehensive review of the literature","volume":"61","author":"Genereux","year":"2013","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.amjcard.2014.12.018_bib19","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.jacc.2008.05.007","article-title":"2008 Focused update incorporated into the ACC\/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease: a report of the American College of Cardiology\/American Heart Association Task Force on Practice Guidelines","volume":"52","author":"Bonow","year":"2008","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.amjcard.2014.12.018_bib20","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1016\/S0002-8703(99)70124-9","article-title":"Natural history of early aortic paraprosthetic regurgitation: a five-year follow-up","volume":"138","author":"Rallidis","year":"1999","journal-title":"Am Heart J"},{"key":"10.1016\/j.amjcard.2014.12.018_bib21","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1016\/j.ahj.2011.05.011","article-title":"Transcatheter aortic valve implantation in patients with severe symptomatic aortic valve stenosis\u2014predictors of mortality and poor treatment response","volume":"162","author":"Gotzmann","year":"2011","journal-title":"Am Heart J"}],"container-title":["The American Journal of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002914914022814?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002914914022814?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,2]],"date-time":"2025-11-02T10:04:00Z","timestamp":1762077840000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0002914914022814"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,3]]},"references-count":21,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2015,3]]}},"alternative-id":["S0002914914022814"],"URL":"https:\/\/doi.org\/10.1016\/j.amjcard.2014.12.018","relation":{},"ISSN":["0002-9149"],"issn-type":[{"value":"0002-9149","type":"print"}],"subject":[],"published":{"date-parts":[[2015,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effect of Aortic Regurgitation Following Transcatheter Aortic Valve Implantation on Outcomes","name":"articletitle","label":"Article Title"},{"value":"The American Journal of Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.amjcard.2014.12.018","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}