{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T01:28:25Z","timestamp":1767922105474,"version":"3.49.0"},"reference-count":26,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2017,2,1]],"date-time":"2017-02-01T00:00:00Z","timestamp":1485907200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","ajconline.org","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The American Journal of Cardiology"],"published-print":{"date-parts":[[2017,2]]},"DOI":"10.1016\/j.amjcard.2016.10.047","type":"journal-article","created":{"date-parts":[[2016,11,16]],"date-time":"2016-11-16T22:33:42Z","timestamp":1479335622000},"page":"618-622","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":18,"title":["Predictors of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation for Aortic Stenosis Using New-Generation Balloon-Expandable SAPIEN 3"],"prefix":"10.1016","volume":"119","author":[{"given":"Hidehiro","family":"Kaneko","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frank","family":"Hoelschermann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Grit","family":"Tambor","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sung-Han","family":"Yoon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Neuss","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9688-4186","authenticated-orcid":false,"given":"Christian","family":"Butter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.amjcard.2016.10.047_bib1","doi-asserted-by":"crossref","first-page":"1597","DOI":"10.1056\/NEJMoa1008232","article-title":"Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery","volume":"363","author":"Leon","year":"2010","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.amjcard.2016.10.047_bib2","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1056\/NEJMoa1103510","article-title":"Transcatheter versus surgical aortic-valve replacement in high-risk patients","volume":"364","author":"Smith","year":"2011","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.amjcard.2016.10.047_bib3","doi-asserted-by":"crossref","first-page":"1247","DOI":"10.1016\/j.jcin.2012.09.003","article-title":"Impact of post-procedural aortic regurgitation on mortality after transcatheter aortic valve implantation","volume":"5","author":"Hayashida","year":"2012","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.amjcard.2016.10.047_bib4","doi-asserted-by":"crossref","first-page":"1686","DOI":"10.1056\/NEJMoa1200384","article-title":"Two-year outcomes after transcatheter or surgical aortic-valve replacement","volume":"366","author":"Kodali","year":"2012","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.amjcard.2016.10.047_bib5","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1161\/CIRCULATIONAHA.110.946533","article-title":"Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis","volume":"123","author":"Tamburino","year":"2011","journal-title":"Circulation"},{"key":"10.1016\/j.amjcard.2016.10.047_bib6","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.jcin.2012.09.019","article-title":"Transcatheter aortic valve replacement with the SAPIEN 3: a new balloon-expandable transcatheter heart valve","volume":"6","author":"Binder","year":"2013","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.amjcard.2016.10.047_bib7","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1016\/j.amjcard.2016.05.053","article-title":"Impact of different iterations of devices and degree of aortic valve calcium on paravalvular regurgitation after transcatheter aortic valve implantation","volume":"118","author":"Kong","year":"2016","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.amjcard.2016.10.047_bib8","doi-asserted-by":"crossref","first-page":"1609","DOI":"10.1056\/NEJMoa1514616","article-title":"Transcatheter or surgical aortic-valve replacement in intermediate-risk patients","volume":"374","author":"Leon","year":"2016","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.amjcard.2016.10.047_bib9","doi-asserted-by":"crossref","first-page":"1438","DOI":"10.1016\/j.jacc.2012.09.001","article-title":"Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document","volume":"60","author":"Kappetein","year":"2012","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.amjcard.2016.10.047_bib10","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1016\/j.jcin.2013.05.008","article-title":"Automated 3-dimensional aortic annular assessment by multidetector computed tomography in transcatheter aortic valve implantation","volume":"6","author":"Watanabe","year":"2013","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.amjcard.2016.10.047_bib11","doi-asserted-by":"crossref","first-page":"1566","DOI":"10.1016\/j.amjcard.2015.08.021","article-title":"Comparison of aortic root anatomy and calcification distribution between Asian and Caucasian patients who underwent transcatheter aortic valve implantation","volume":"116","author":"Yoon","year":"2015","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.amjcard.2016.10.047_bib12","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.jcin.2012.09.007","article-title":"Aortic root dimensions among patients with severe aortic stenosis undergoing transcatheter aortic valve replacement","volume":"6","author":"Buellesfeld","year":"2013","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.amjcard.2016.10.047_bib13","doi-asserted-by":"crossref","first-page":"1324","DOI":"10.1093\/ehjci\/jeu162","article-title":"A\u00a0revised methodology for aortic-valvar complex calcium quantification for transcatheter aortic valve implantation","volume":"15","author":"Jilaihawi","year":"2014","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"10.1016\/j.amjcard.2016.10.047_bib14","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1016\/j.jcin.2014.03.007","article-title":"Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement","volume":"7","author":"Khalique","year":"2014","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.amjcard.2016.10.047_bib15","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1016\/j.jcin.2014.10.014","article-title":"Incidence and severity of paravalvular aortic regurgitation with multidetector computed tomography nominal area oversizing or undersizing after transcatheter heart valve replacement with the Sapien 3: a comparison with the Sapien XT","volume":"8","author":"Yang","year":"2015","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.amjcard.2016.10.047_bib16","doi-asserted-by":"crossref","first-page":"2252","DOI":"10.1093\/eurheartj\/ehw112","article-title":"Early clinical and echocardiographic outcomes after SAPIEN 3 transcatheter aortic valve replacement in inoperable, high-risk and intermediate-risk patients with aortic stenosis","volume":"37","author":"Kodali","year":"2016","journal-title":"Eur Heart J"},{"key":"10.1016\/j.amjcard.2016.10.047_bib17","doi-asserted-by":"crossref","first-page":"2235","DOI":"10.1016\/j.jacc.2014.09.026","article-title":"Multicenter evaluation of a next-generation balloon-expandable transcatheter aortic valve","volume":"64","author":"Webb","year":"2014","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.amjcard.2016.10.047_bib18","doi-asserted-by":"crossref","first-page":"e0151247","DOI":"10.1371\/journal.pone.0151247","article-title":"Transfemoral aortic valve implantation with the new Edwards Sapien 3 valve for treatment of severe aortic stenosis-impact of valve size in a single center experience","volume":"11","author":"Wohrle","year":"2016","journal-title":"PLoS One"},{"key":"10.1016\/j.amjcard.2016.10.047_bib19","doi-asserted-by":"crossref","first-page":"1585","DOI":"10.1016\/j.jacc.2013.01.047","article-title":"Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature","volume":"61","author":"Athappan","year":"2013","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.amjcard.2016.10.047_bib20","doi-asserted-by":"crossref","first-page":"899","DOI":"10.1136\/hrt.2010.217158","article-title":"Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German Transcatheter Aortic Valve Interventions registry","volume":"97","author":"Abdel-Wahab","year":"2011","journal-title":"Heart"},{"key":"10.1016\/j.amjcard.2016.10.047_bib21","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/j.jacc.2011.10.857","article-title":"Transapical aortic valve implantation: incidence and predictors of paravalvular leakage and transvalvular regurgitation in a series of 358 patients","volume":"59","author":"Unbehaun","year":"2012","journal-title":"J\u00a0Am Coll Cardiol"},{"key":"10.1016\/j.amjcard.2016.10.047_bib22","doi-asserted-by":"crossref","first-page":"1470","DOI":"10.1016\/j.amjcard.2011.07.007","article-title":"Location and severity of aortic valve calcium and implications for aortic regurgitation after transcatheter aortic valve implantation","volume":"108","author":"Ewe","year":"2011","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.amjcard.2016.10.047_bib23","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/j.ijcard.2010.03.004","article-title":"Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation","volume":"150","author":"Koos","year":"2011","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.amjcard.2016.10.047_bib24","doi-asserted-by":"crossref","first-page":"1234","DOI":"10.1093\/ejcts\/ezr244","article-title":"Aortic valve calcium scoring is a predictor of significant paravalvular aortic insufficiency in transapical-aortic valve implantation","volume":"41","author":"Haensig","year":"2012","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.amjcard.2016.10.047_bib25","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1016\/j.jcmg.2015.10.011","article-title":"Predictors for paravalvular regurgitation after TAVR with the self-expanding prosthesis: quantitative measurement of MDCT analysis","volume":"9","author":"Yoon","year":"2016","journal-title":"JACC Cardiovasc Imaging"},{"key":"10.1016\/j.amjcard.2016.10.047_bib26","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1016\/j.jcin.2009.07.003","article-title":"Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence","volume":"2","author":"Detaint","year":"2009","journal-title":"JACC Cardiovasc Interv"}],"container-title":["The American Journal of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002914916318227?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002914916318227?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,6]],"date-time":"2018-09-06T12:52:26Z","timestamp":1536238346000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0002914916318227"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,2]]},"references-count":26,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2017,2]]}},"alternative-id":["S0002914916318227"],"URL":"https:\/\/doi.org\/10.1016\/j.amjcard.2016.10.047","relation":{},"ISSN":["0002-9149"],"issn-type":[{"value":"0002-9149","type":"print"}],"subject":[],"published":{"date-parts":[[2017,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Predictors of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation for Aortic Stenosis Using New-Generation Balloon-Expandable SAPIEN 3","name":"articletitle","label":"Article Title"},{"value":"The American Journal of Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.amjcard.2016.10.047","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}