{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,16]],"date-time":"2025-09-16T16:31:25Z","timestamp":1758040285324,"version":"3.44.0"},"reference-count":16,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T00:00:00Z","timestamp":1693526400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T00:00:00Z","timestamp":1693526400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["ajconline.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The American Journal of Cardiology"],"published-print":{"date-parts":[[2023,9]]},"DOI":"10.1016\/j.amjcard.2023.06.020","type":"journal-article","created":{"date-parts":[[2023,6,27]],"date-time":"2023-06-27T08:08:53Z","timestamp":1687853333000},"page":"490-492","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"special_numbering":"C","title":["Mitigating Conduction Disturbances After Transcatheter Aortic Valve Replacement"],"prefix":"10.1016","volume":"203","author":[{"given":"Hiren","family":"Patel","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Div","family":"Verma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9441-296X","authenticated-orcid":false,"given":"Kishore","family":"Harjai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.amjcard.2023.06.020_bib0001","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1056\/NEJMoa1103510","article-title":"Transcatheter versus surgical aortic-valve replacement in high-risk patients","volume":"364","author":"Smith","year":"2011","journal-title":"N Engl J Med"},{"key":"10.1016\/j.amjcard.2023.06.020_bib0002","doi-asserted-by":"crossref","first-page":"1790","DOI":"10.1056\/NEJMoa1400590","article-title":"Transcatheter aortic-valve replacement with a self-expanding prosthesis","volume":"370","author":"Adams","year":"2014","journal-title":"N Engl J Med"},{"key":"10.1016\/j.amjcard.2023.06.020_bib0003","doi-asserted-by":"crossref","first-page":"1695","DOI":"10.1056\/NEJMoa1814052","article-title":"Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients","volume":"380","author":"Mack","year":"2019","journal-title":"N Engl J Med"},{"key":"10.1016\/j.amjcard.2023.06.020_bib0004","doi-asserted-by":"crossref","first-page":"1706","DOI":"10.1056\/NEJMoa1816885","article-title":"Evolut Low Risk Trial Investigators. Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients","volume":"380","author":"Popma","year":"2019","journal-title":"N Engl J Med"},{"key":"10.1016\/j.amjcard.2023.06.020_bib0005","doi-asserted-by":"crossref","first-page":"35","DOI":"10.7326\/0003-4819-158-1-201301010-00007","article-title":"Adverse effects associated with transcatheter aortic valve implantation: a meta-analysis of contemporary studies","volume":"158","author":"Khatri","year":"2013","journal-title":"Ann Intern Med"},{"key":"10.1016\/j.amjcard.2023.06.020_bib0006","doi-asserted-by":"crossref","first-page":"1743","DOI":"10.1016\/j.jacc.2012.07.035","article-title":"Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve","volume":"60","author":"Urena","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.amjcard.2023.06.020_bib0007","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1161\/CIRCULATIONAHA.117.028352","article-title":"Conduction disturbances after transcatheter aortic valve replacement: current status and future perspectives","volume":"136","author":"Auffret","year":"2017","journal-title":"Circulation"},{"key":"10.1016\/j.amjcard.2023.06.020_bib0008","doi-asserted-by":"crossref","first-page":"2200","DOI":"10.1016\/j.jcin.2016.08.034","article-title":"Predictors of permanent pacemaker implantation after transcatheter aortic valve replacement with the SAPIEN 3","volume":"9","author":"Mauri","year":"2016","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.amjcard.2023.06.020_bib0009","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.jcin.2014.07.022","article-title":"PARTNER Publications Office. Predictors and clinical outcomes of permanent pacemaker implantation after transcatheter aortic valve replacement: the PARTNER (Placement of AoRtic transcatheter Valves) trial and registry","volume":"1","author":"Nazif","year":"2015","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.amjcard.2023.06.020_bib0010","doi-asserted-by":"crossref","first-page":"2391","DOI":"10.1016\/j.jacc.2020.08.050","article-title":"2020 ACC Expert Consensus decision pathway on management of conduction disturbances in patients undergoing transcatheter aortic valve replacement: a report of the American College of Cardiology solution set oversight committee","volume":"76","author":"Lilly","year":"2020","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.amjcard.2023.06.020_bib0011","doi-asserted-by":"crossref","first-page":"3427","DOI":"10.1093\/eurheartj\/ehab364","volume":"42","author":"Glikson","year":"2021","journal-title":"Eur Heart J"},{"key":"10.1016\/j.amjcard.2023.06.020_bib0012","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1016\/j.jacc.2018.10.043","volume":"74","author":"Kusumoto","year":"2019","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.amjcard.2023.06.020_bib0013","doi-asserted-by":"crossref","first-page":"1576","DOI":"10.1111\/jce.15525","article-title":"Predictors of conduction disturbances after transcatheter aortic valve implantation with balloon-expandable valve for bicuspid aortic valve stenosis","volume":"33","author":"Miyashita","year":"2022","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.amjcard.2023.06.020_bib0014","doi-asserted-by":"crossref","first-page":"1796","DOI":"10.1016\/j.jcin.2019.05.056","article-title":"Minimizing permanent pacemaker following repositionable self-expanding transcatheter aortic valve replacement","volume":"12","author":"Jilaihawi","year":"2019","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.amjcard.2023.06.020_bib0015","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.120.009028","article-title":"Anatomical predictors of pacemaker dependency after transcatheter aortic valve replacement","volume":"14","author":"Nai Fovino","year":"2021","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.amjcard.2023.06.020_bib0016","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1016\/j.jcin.2019.07.048","article-title":"Navigating the \u201coptimal implantation depth\u201d with a self-expandable TAVR device in daily clinical practice","volume":"13","author":"Piayda","year":"2020","journal-title":"JACC Cardiovasc Interv"}],"container-title":["The American Journal of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002914923003910?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002914923003910?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T06:51:11Z","timestamp":1757573471000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0002914923003910"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9]]},"references-count":16,"alternative-id":["S0002914923003910"],"URL":"https:\/\/doi.org\/10.1016\/j.amjcard.2023.06.020","relation":{},"ISSN":["0002-9149"],"issn-type":[{"type":"print","value":"0002-9149"}],"subject":[],"published":{"date-parts":[[2023,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Mitigating Conduction Disturbances After Transcatheter Aortic Valve Replacement","name":"articletitle","label":"Article Title"},{"value":"The American Journal of Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.amjcard.2023.06.020","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"simple-article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}