{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T07:21:51Z","timestamp":1792653711025,"version":"4.5.0"},"reference-count":27,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100004331","name":"Johnson and Johnson","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004331","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["americanjournalofsurgery.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The American Journal of Surgery"],"published-print":{"date-parts":[[2018,1]]},"DOI":"10.1016\/j.amjsurg.2017.04.013","type":"journal-article","created":{"date-parts":[[2017,6,7]],"date-time":"2017-06-07T20:16:07Z","timestamp":1496866567000},"page":"186-190","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":17,"title":["Safety assessment of the use of ultrasonic energy in the proximity of the recurrent laryngeal nerve in a porcine model"],"prefix":"10.1016","volume":"215","author":[{"given":"Karla V.","family":"Ch\u00e1vez","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elpidio M.","family":"Barajas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco","family":"Soroa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Armando","family":"Gamboa-Dominguez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samuel","family":"Ord\u00f3\u00f1ez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6620-3167","authenticated-orcid":false,"given":"Juan P.","family":"Pantoja","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mauricio","family":"Sierra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Vel\u00e1zquez-Fern\u00e1ndez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miguel F.","family":"Herrera","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"4","key":"10.1016\/j.amjsurg.2017.04.013_bib1","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1586\/17434440.5.4.447","article-title":"Novel hemostatic devices in thyroid surgery: electrothermal bipolar vessel sealing system and harmonic scalpel","volume":"5","author":"Manouras","year":"2008","journal-title":"Expert Rev Med Dev"},{"issue":"1","key":"10.1016\/j.amjsurg.2017.04.013_bib2","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1089\/109264204322862289","article-title":"Efficacy and cost-effectiveness of the UltraCision harmonic scalpel in thyroid surgery: an analysis of 200 cases in a randomized trial","volume":"14","author":"Ortega","year":"2004","journal-title":"J\u00a0Laparoendosc Adv Surg Tech Part A"},{"issue":"2","key":"10.1016\/j.amjsurg.2017.04.013_bib3","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1001\/archsurg.137.2.137","article-title":"The use of the harmonic scalpel vs conventional knot tying for vessel ligation in thyroid surgery","volume":"137","author":"Siperstein","year":"2002","journal-title":"Arch Surg Chic Ill 1960)"},{"issue":"10","key":"10.1016\/j.amjsurg.2017.04.013_bib4","doi-asserted-by":"crossref","first-page":"1069","DOI":"10.1001\/archotol.132.10.1069","article-title":"Randomized controlled trial of harmonic scalpel use during thyroidectomy","volume":"132","author":"Miccoli","year":"2006","journal-title":"Arch Otolaryngol Head Neck Surg"},{"issue":"1","key":"10.1016\/j.amjsurg.2017.04.013_bib5","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/j.amjsurg.2007.01.037","article-title":"Thyroid surgery: comparison between the electrothermal bipolar vessel sealing system, harmonic scalpel, and classic suture ligation","volume":"195","author":"Manouras","year":"2008","journal-title":"Am J Surg"},{"issue":"3","key":"10.1016\/j.amjsurg.2017.04.013_bib6","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1080\/00015458.2003.11679422","article-title":"Evaluation of the ultrasonic dissector in thyroid surgery. A prospective randomised study","volume":"103","author":"Defechereux","year":"2003","journal-title":"Acta Chir Belg"},{"issue":"3","key":"10.1016\/j.amjsurg.2017.04.013_bib7","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1097\/00000658-200003000-00004","article-title":"Ultrasonically activated shears in thyroidectomies: a randomized trial","volume":"231","author":"Voutilainen","year":"2000","journal-title":"Ann Surg"},{"issue":"3","key":"10.1016\/j.amjsurg.2017.04.013_bib8","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1007\/BF02848788","article-title":"A\u00a0prospective randomized trial comparing the harmonic scalpel with conventional knot tying in thyroidectomy","volume":"24","author":"Kilic","year":"2007","journal-title":"Adv Ther"},{"issue":"8","key":"10.1016\/j.amjsurg.2017.04.013_bib9","doi-asserted-by":"crossref","first-page":"1228","DOI":"10.1007\/s00464-002-8833-7","article-title":"Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries","volume":"17","author":"Harold","year":"2003","journal-title":"Surg Endosc"},{"issue":"6","key":"10.1016\/j.amjsurg.2017.04.013_bib10","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1002\/bjs.4948","article-title":"Comparison of experimental nerve injury caused by ultrasonically activated scalpel and electrosurgery","volume":"92","author":"Carlander","year":"2005","journal-title":"Br J Surg"},{"issue":"7","key":"10.1016\/j.amjsurg.2017.04.013_bib11","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1055\/s-2002-33221","article-title":"The ultrasonic coagulating and cutting system injures nerve function","volume":"34","author":"Owaki","year":"2002","journal-title":"Endoscopy"},{"issue":"4","key":"10.1016\/j.amjsurg.2017.04.013_bib12","doi-asserted-by":"crossref","first-page":"223","DOI":"10.5625\/lar.2012.28.4.223","article-title":"Development of a canine model for recurrent laryngeal injury by harmonic scalpel","volume":"28","author":"Lee","year":"2012","journal-title":"Lab Anim Res"},{"issue":"10","key":"10.1016\/j.amjsurg.2017.04.013_bib13","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.1002\/hed.21324","article-title":"Investigation of optimal intensity and safety of electrical nerve stimulation during intraoperative neuromonitoring of the recurrent laryngeal nerve: a prospective porcine model","volume":"32","author":"Wu","year":"2010","journal-title":"Head Neck"},{"issue":"6","key":"10.1016\/j.amjsurg.2017.04.013_bib14","doi-asserted-by":"crossref","first-page":"856","DOI":"10.3109\/02688697.2012.697216","article-title":"The effects of ultrasonic and electrosurgery devices on nerve physiology","volume":"26","author":"Chen","year":"2012","journal-title":"Br J Neurosurg"},{"issue":"6","key":"10.1016\/j.amjsurg.2017.04.013_bib15","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1007\/s00423-006-0082-0","article-title":"The use of LigaSure in patients with hyperthyroidism","volume":"391","author":"Barbaros","year":"2006","journal-title":"Langenbeck's Arch Surg"},{"issue":"2","key":"10.1016\/j.amjsurg.2017.04.013_bib16","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1007\/s00423-014-1270-y","article-title":"A\u00a0comparison of the outcome using Ligasure\u2122 small jaw and clamp-and-tie technique in thyroidectomy: a randomized single center study","volume":"400","author":"Coiro","year":"2015","journal-title":"Langenbeck's Arch Surg"},{"issue":"2","key":"10.1016\/j.amjsurg.2017.04.013_bib17","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1177\/000313480607200207","article-title":"Safely increasing the efficiency of thyroidectomy using a new bipolar electrosealing device (LigaSure) versus conventional clamp-and-tie technique","volume":"72","author":"Franko","year":"2006","journal-title":"Am Surg"},{"issue":"6","key":"10.1016\/j.amjsurg.2017.04.013_bib18","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1007\/s00268-005-7788-y","article-title":"Use of ligasure in thyroidectomy procedures: results of a prospective comparative study","volume":"29","author":"Kirdak","year":"2005","journal-title":"World J Surg"},{"issue":"3","key":"10.1016\/j.amjsurg.2017.04.013_bib19","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1016\/j.amjsurg.2007.12.009","article-title":"The use of the Ligasure for hemostasis during thyroid lobectomy","volume":"195","author":"Musunuru","year":"2008","journal-title":"Am J Surg"},{"issue":"1","key":"10.1016\/j.amjsurg.2017.04.013_bib20","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1016\/j.jss.2011.03.005","article-title":"Infrared thermographic profiles of vessel sealing devices on thyroid parenchyma","volume":"170","author":"Smith","year":"2011","journal-title":"J\u00a0Surg Res"},{"issue":"10","key":"10.1016\/j.amjsurg.2017.04.013_bib21","doi-asserted-by":"crossref","first-page":"1640","DOI":"10.1007\/s00464-002-8781-2","article-title":"Real-time thermography during energized vessel sealing and dissection","volume":"17","author":"Campbell","year":"2003","journal-title":"Surg Endosc"},{"issue":"6","key":"10.1016\/j.amjsurg.2017.04.013_bib22","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1007\/s004649901055","article-title":"Experimental study on heat production by a 23.5-kHz ultrasonically activated device for endoscopic surgery","volume":"13","author":"Kinoshita","year":"1999","journal-title":"Surg Endosc"},{"issue":"4","key":"10.1016\/j.amjsurg.2017.04.013_bib23","doi-asserted-by":"crossref","first-page":"569","DOI":"10.3109\/02688697.2015.1023772","article-title":"Acute and subacute effects of the ultrasonic blade and electrosurgery on nerve physiology","volume":"29","author":"Chen","year":"2015","journal-title":"Br J Neurosurg"},{"issue":"1","key":"10.1016\/j.amjsurg.2017.04.013_bib24","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.jss.2015.06.066","article-title":"Thermal injury of the recurrent laryngeal nerve by THUNDERBEAT during thyroid surgery: findings from continuous intraoperative neuromonitoring in a","volume":"200","author":"Kwak","year":"2015","journal-title":"J\u00a0Surg Res"},{"issue":"12","key":"10.1016\/j.amjsurg.2017.04.013_bib25","doi-asserted-by":"crossref","first-page":"2838","DOI":"10.1002\/lary.25412","article-title":"Recurrent laryngeal nerve safety parameters of the Harmonic Focus during thyroid surgery: porcine model using continuous monitoring","volume":"125","author":"Wu","year":"2015","journal-title":"Laryngoscope"},{"key":"10.1016\/j.amjsurg.2017.04.013_bib26","doi-asserted-by":"crossref","unstructured":"Jiang JJ, Raviv JR, Hanson DG. Comparison of the phonation-related structures among pig, dog, white-tailed deer, and human larynges. Ann Otol Rhinol Laryngol 110:1120\u20131125.","DOI":"10.1177\/000348940111001207"},{"key":"10.1016\/j.amjsurg.2017.04.013_bib27","first-page":"283","article-title":"Electrophysiologic monitoring correlates of recurrent laryngeal nerve heat thermal injury in a porcine model","volume":"125","author":"Yi-Chu","year":"2015","journal-title":"Laryngoscope"}],"container-title":["The American Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002961017300764?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002961017300764?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,12]],"date-time":"2025-09-12T18:08:52Z","timestamp":1757700532000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0002961017300764"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1]]},"references-count":27,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,1]]}},"alternative-id":["S0002961017300764"],"URL":"https:\/\/doi.org\/10.1016\/j.amjsurg.2017.04.013","relation":{},"ISSN":["0002-9610"],"issn-type":[{"value":"0002-9610","type":"print"}],"subject":[],"published":{"date-parts":[[2018,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Safety assessment of the use of ultrasonic energy in the proximity of the recurrent laryngeal nerve in a porcine model","name":"articletitle","label":"Article Title"},{"value":"The American Journal of Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.amjsurg.2017.04.013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}