{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,19]],"date-time":"2026-06-19T21:44:25Z","timestamp":1781905465425,"version":"3.54.5"},"reference-count":20,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,3,26]],"date-time":"2026-03-26T00:00:00Z","timestamp":1774483200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000005","name":"US Department of Defense","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000005","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["americanjournalofsurgery.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The American Journal of Surgery"],"published-print":{"date-parts":[[2026,7]]},"DOI":"10.1016\/j.amjsurg.2026.116924","type":"journal-article","created":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T07:38:48Z","timestamp":1773905928000},"page":"116924","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"special_numbering":"C","title":["Non-compressible torso hemorrhage control with intravascular ultrasound guided resuscitative endovascular balloon occlusion"],"prefix":"10.1016","volume":"257","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-1220-775X","authenticated-orcid":false,"given":"Anna Maria","family":"Rogalska","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-9513-0016","authenticated-orcid":false,"given":"Micaela","family":"Cuneo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher","family":"Goei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ashley","family":"Flinn Patterson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7538-2099","authenticated-orcid":false,"given":"Jason","family":"Rall","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephanie S.","family":"Combs","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-1376-0396","authenticated-orcid":false,"given":"Theodore G.","family":"Hart","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marlin Wayne","family":"Causey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.amjsurg.2026.116924_bib1","first-page":"S431","article-title":"Death on the battlefield (2001-2011): implications for the future of combat casualty care","volume":"6","author":"Eastridge","year":"2012"},{"issue":"1","key":"10.1016\/j.amjsurg.2026.116924_bib2","doi-asserted-by":"crossref","first-page":"e001515","DOI":"10.1136\/tsaco-2024-001515","article-title":"Resuscitative endovascular balloon occlusion of the aorta (REBOA) for non-trauma patients in an urban hospital: a series of two cases","volume":"9","author":"van de Voort","year":"2024","journal-title":"Trauma surgery & acute care open"},{"key":"10.1016\/j.amjsurg.2026.116924_bib3","article-title":"RESUSCITATIVE ENDOVASCULAR BALLOON OCCLUSION OF THE AORTA (REBOA) evidence based medicine guideline","author":"Evans","year":"2018","journal-title":"Surgical Critical Care"},{"issue":"1","key":"10.1016\/j.amjsurg.2026.116924_bib4","article-title":"Complications associated with the use of resuscitative endovascular balloon occlusion of the aorta (REBOA): an updated review. Trauma surgery & acute care","volume":"9","author":"Marcelo Augusto Fontenelle Ribeiro","year":"2024","journal-title":"Open"},{"key":"10.1016\/j.amjsurg.2026.116924_bib5","article-title":"Resuscitative endovascular balloon occlusion of the aorta (REBOA) for hemorrhagic shock","author":"Glaser","year":"2023","journal-title":"Syst J"},{"key":"10.1016\/j.amjsurg.2026.116924_bib6","series-title":"Guide for the Care and Use of Laboratory Animals","first-page":"246","author":"Council","year":"2011"},{"issue":"1","key":"10.1016\/j.amjsurg.2026.116924_bib7","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1186\/s12917-020-02451-y","article-title":"The ARRIVE guidelines 2.0: updated guidelines for reporting animal research","volume":"16","author":"Percie du Sert","year":"2020","journal-title":"BMC Vet Res"},{"key":"10.1016\/j.amjsurg.2026.116924_bib9","series-title":"Swine in the Laboratory Surgery, Anesthesia, Imaging, and Experimental Techniques","author":"Swindle","year":"2016"},{"key":"10.1016\/j.amjsurg.2026.116924_bib10","doi-asserted-by":"crossref","DOI":"10.1093\/milmed\/usaf221","article-title":"Advances in combat vascular trauma care through translational animal research across United States military service branches","author":"Rogalska","year":"2025","journal-title":"Mil Med"},{"issue":"2","key":"10.1016\/j.amjsurg.2026.116924_bib11","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.jamcollsurg.2016.04.037","article-title":"Partial resuscitative endovascular balloon occlusion of the aorta in swine model of hemorrhagic shock","volume":"223","author":"Russo","year":"2016","journal-title":"J Am Coll Surg"},{"issue":"1","key":"10.1016\/j.amjsurg.2026.116924_bib12","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-022-23524-y","article-title":"Organ perfusion during partial REBOA in haemorrhagic shock: dynamic 4D-CT analyses in swine","volume":"12","author":"Matsumura","year":"2022","journal-title":"Sci Rep"},{"issue":"1","key":"10.1016\/j.amjsurg.2026.116924_bib13","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/s40635-023-00502-w","article-title":"A randomized porcine study of hemorrhagic shock comparing end-tidal carbon dioxide targeted and proximal systolic blood pressure targeted partial resuscitative endovascular balloon occlusion of the aorta in the mitigation of metabolic injury","volume":"11","author":"Stene Hurts\u00e9n","year":"2023","journal-title":"Intensive Care Med Exp"},{"issue":"4","key":"10.1016\/j.amjsurg.2026.116924_bib14","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1007\/s00068-019-01257-4","article-title":"Distal pressure monitoring and titration with percent balloon volume: feasible management of partial resuscitative endovascular balloon occlusion of the aorta (P-REBOA)","volume":"47","author":"Matsumura","year":"2021","journal-title":"Eur J Trauma Emerg Surg"},{"issue":"3","key":"10.1016\/j.amjsurg.2026.116924_bib15","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1097\/TA.0000000000000940","article-title":"Extending the golden hour: partial resuscitative endovascular balloon occlusion of the aorta in a highly lethal swine liver injury model","volume":"80","author":"Russo","year":"2016","journal-title":"J Trauma Acute Care Surg"},{"issue":"2S Suppl 1","key":"10.1016\/j.amjsurg.2026.116924_bib16","doi-asserted-by":"crossref","first-page":"S94","DOI":"10.1097\/TA.0000000000003667","article-title":"The physiology of aortic flow and pressures during partial resuscitative endovascular balloon occlusion of the aorta in a swine model of hemorrhagic shock","volume":"93","author":"Marble","year":"2022","journal-title":"J Trauma Acute Care Surg"},{"issue":"1","key":"10.1016\/j.amjsurg.2026.116924_bib17","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1097\/TA.0000000000002075","article-title":"Aortic branch vessel flow during resuscitative endovascular balloon occlusion of the aorta","volume":"86","author":"Hoehn","year":"2019","journal-title":"J Trauma Acute Care Surg"},{"issue":"1","key":"10.1016\/j.amjsurg.2026.116924_bib18","doi-asserted-by":"crossref","DOI":"10.1136\/tsaco-2020-000443","article-title":"Placement accuracy of resuscitative endovascular occlusion balloon into the target zone with external measurement","volume":"5","author":"Matsumoto","year":"2020","journal-title":"Trauma Surg Acute Care Open"},{"issue":"3","key":"10.1016\/j.amjsurg.2026.116924_bib19","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1097\/TA.0000000000001106","article-title":"Emergent non-image-guided resuscitative endovascular balloon occlusion of the aorta (REBOA) catheter placement: a cadaver-based study","volume":"81","author":"Linnebur","year":"2016","journal-title":"J Trauma Acute Care Surg"},{"issue":"1","key":"10.1016\/j.amjsurg.2026.116924_bib20","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1097\/XCS.0000000000000403","article-title":"Partial vs full resuscitative endovascular balloon occlusion of the aorta (REBOA) in a swine model of raised intracranial pressure and hemorrhagic shock","volume":"236","author":"Edwards","year":"2023","journal-title":"J Am Coll Surg"},{"issue":"6","key":"10.1016\/j.amjsurg.2026.116924_bib21","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1016\/S0735-6757(03)00162-1","article-title":"Sensitivity in detecting free intraperitoneal fluid with the pelvic views of the FAST exam","volume":"21","author":"Von Kuenssberg Jehle","year":"2003","journal-title":"Am J Emerg Med"}],"container-title":["The American Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002961026001078?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002961026001078?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T06:42:38Z","timestamp":1779259358000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0002961026001078"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":20,"alternative-id":["S0002961026001078"],"URL":"https:\/\/doi.org\/10.1016\/j.amjsurg.2026.116924","relation":{},"ISSN":["0002-9610"],"issn-type":[{"value":"0002-9610","type":"print"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Non-compressible torso hemorrhage control with intravascular ultrasound guided resuscitative endovascular balloon occlusion","name":"articletitle","label":"Article Title"},{"value":"The American Journal of Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.amjsurg.2026.116924","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier Inc.","name":"copyright","label":"Copyright"}],"article-number":"116924"}}