{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T17:53:35Z","timestamp":1761155615817,"version":"3.44.0"},"reference-count":31,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2012,11,1]],"date-time":"2012-11-01T00:00:00Z","timestamp":1351728000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2012,11,1]],"date-time":"2012-11-01T00:00:00Z","timestamp":1351728000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2012,11,1]],"date-time":"2012-11-01T00:00:00Z","timestamp":1351728000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2012,11,1]],"date-time":"2012-11-01T00:00:00Z","timestamp":1351728000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2012,11,1]],"date-time":"2012-11-01T00:00:00Z","timestamp":1351728000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2012,11,1]],"date-time":"2012-11-01T00:00:00Z","timestamp":1351728000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2012,11,1]],"date-time":"2012-11-01T00:00:00Z","timestamp":1351728000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["clinicalkey.fr","em-consulte.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Annales de Cardiologie et d'Ang\u00e9iologie"],"published-print":{"date-parts":[[2012,11]]},"DOI":"10.1016\/j.ancard.2012.08.033","type":"journal-article","created":{"date-parts":[[2012,10,1]],"date-time":"2012-10-01T13:47:45Z","timestamp":1349099265000},"page":"331-337","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Suivi \u00e0 long terme apr\u00e8s pose de holter implantable pour syncope\u00a0: r\u00e9sultats d\u2019un registre men\u00e9 dans un centre hospitalier"],"prefix":"10.1016","volume":"61","author":[{"given":"H.","family":"Salih","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F.","family":"Monsel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Sergent","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"W.","family":"Amara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.ancard.2012.08.033_bib0005","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.1016\/S0002-9149(03)00127-9","article-title":"Prevalence and triggers of syncope in medical students","volume":"91","author":"Ganzeboom","year":"2003","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.ancard.2012.08.033_bib0010","doi-asserted-by":"crossref","first-page":"1965","DOI":"10.1093\/eurheartj\/ehl147","article-title":"Vasovagal syncope in medical students and their first-degree relatives","volume":"27","author":"Serletis","year":"2006","journal-title":"Eur Heart J"},{"issue":"Suppl. 1","key":"10.1016\/j.ancard.2012.08.033_bib0015","doi-asserted-by":"crossref","first-page":"i9","DOI":"10.1007\/s10286-004-1003-3","article-title":"Epidemiology of reflex syncope","volume":"14","author":"Colman","year":"2004","journal-title":"Clin Auton Res"},{"key":"10.1016\/j.ancard.2012.08.033_bib0020","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1016\/j.ehj.2004.05.013","article-title":"Incidence, diagnostic yield and safety of the implantable loop-recorder to detect the mechanism of syncope in patients with and without structural heart disease","volume":"25","author":"Solano","year":"2004","journal-title":"Eur Heart J"},{"key":"10.1016\/j.ancard.2012.08.033_bib0025","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1161\/hc3601.095708","article-title":"Mechanism of syncope in patients with isolated syncope and in patients with tilt positive syncope","volume":"104","author":"Moya","year":"2001","journal-title":"Circulation"},{"key":"10.1016\/j.ancard.2012.08.033_bib0030","doi-asserted-by":"crossref","first-page":"2741","DOI":"10.1161\/01.CIR.0000018125.31973.87","article-title":"Mechanism of syncope in patients with heart disease and negative electrophysiologic test","volume":"105","author":"Menozzi","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.ancard.2012.08.033_bib0035","doi-asserted-by":"crossref","first-page":"2045","DOI":"10.1161\/hc4201.097837","article-title":"The mechanism of syncope in patients with bundle branch block and negative electrophysiologic test","volume":"104","author":"Brignole","year":"2001","journal-title":"Circulation"},{"key":"10.1016\/j.ancard.2012.08.033_bib0040","doi-asserted-by":"crossref","first-page":"1819","DOI":"10.1161\/01.CIR.92.7.1819","article-title":"The etiology of syncope in patients with negative tilt table and electrophysiologic testing","volume":"92","author":"Krahn","year":"1995","journal-title":"Circulation"},{"key":"10.1016\/j.ancard.2012.08.033_bib0045","doi-asserted-by":"crossref","unstructured":"Krahn AD, Klein GJ, Yee R, Takle-Newhouse T, Norris C. Use of an extended monitoring strategy in patients with problematic syncope. Reveal Investigators. Circulation 1999;99:406\u201310.","DOI":"10.1161\/01.CIR.99.3.406"},{"key":"10.1016\/j.ancard.2012.08.033_bib0050","doi-asserted-by":"crossref","first-page":"1532","DOI":"10.1046\/j.1460-9592.2000.01532.x","article-title":"Heart rhythm during syncope and presyncope","volume":"23","author":"Nierop","year":"2000","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.ancard.2012.08.033_bib0055","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/j.eupc.2003.09.006","article-title":"Value of implantable loop recorder for the management of patients with unexplained syncope","volume":"6","author":"Boersma","year":"2004","journal-title":"Europace"},{"key":"10.1016\/j.ancard.2012.08.033_bib0060","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.eupc.2004.09.003","article-title":"Utility of implantable loop recorder (Reveal Plus) in the diagnosis of unexplained syncope","volume":"7","author":"Lombardi","year":"2005","journal-title":"Europace"},{"key":"10.1016\/j.ancard.2012.08.033_bib0065","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1093\/europace\/eun039","article-title":"Implantable loop recorder for recurrent syncope: influence of cardiac conduction abnormalities showing up on resting electrocardiogram and of underlying cardiac disease on follow-up developments","volume":"10","author":"Pierre","year":"2008","journal-title":"Europace"},{"key":"10.1016\/j.ancard.2012.08.033_bib0070","doi-asserted-by":"crossref","first-page":"1475","DOI":"10.1093\/europace\/euq302","article-title":"Discrepancy between clinical practice and standardized indications for an implantable loop recorder in patients with unexplained syncope","volume":"12","author":"Vitale","year":"2010","journal-title":"Europace"},{"key":"10.1016\/j.ancard.2012.08.033_bib0075","doi-asserted-by":"crossref","first-page":"2566","DOI":"10.1161\/CIRCULATIONAHA.111.082313","article-title":"Third internetionnal study on syncope of uncertain etiology (ISSUE-3) a randomized trial","volume":"125","author":"Brignole","year":"2012","journal-title":"Circulation"},{"key":"10.1016\/j.ancard.2012.08.033_bib0080","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1093\/eurheartj\/ehi842","article-title":"Early application of an implantable loop recorder allows effective specific therapy in patients with recurrent suspected neurally mediated syncope","volume":"27","author":"Brignole","year":"2006","journal-title":"Eur Heart J"},{"key":"10.1016\/j.ancard.2012.08.033_bib0085","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1093\/europace\/eum092","article-title":"Cardioinhibitory carotid sinus hypersensitivity predicts an asystolic mechanism of spontaneous neurally mediated syncope","volume":"9","author":"Maggi","year":"2007","journal-title":"Europace"},{"key":"10.1016\/j.ancard.2012.08.033_bib0090","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1046\/j.1460-9592.2002.00037.x","article-title":"Predicting the outcome of patients with unexplained syncope undergoing prolonged monitoring","volume":"25","author":"Krahn","year":"2002","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.ancard.2012.08.033_bib0095","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1136\/hrt.2007.116616","article-title":"Implantable loop recorder in unexplained syncope: classification, mechanism, transient loss of consciousness and role of major depressive disorder in patients with and without structural heart disease","volume":"94","author":"Pezawas","year":"2008","journal-title":"Heart"},{"key":"10.1016\/j.ancard.2012.08.033_bib0100","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/S0735-1097(02)02621-9","article-title":"Mechanism of syncope in patients with positive adenosine triphosphate tests","volume":"41","author":"Donateo","year":"2003","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ancard.2012.08.033_bib0105","doi-asserted-by":"crossref","first-page":"2232","DOI":"10.1093\/eurheartj\/ehl164","article-title":"Lack of correlation between the responses to tilt testing and adenosine triphosphate test and the mechanism of spontaneous neurally-mediated syncope","volume":"27","author":"Brignole","year":"2006","journal-title":"Eur Heart J"},{"key":"10.1016\/j.ancard.2012.08.033_bib0110","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1016\/j.jacc.2005.09.043","article-title":"An implantable loop recorder study of highly symptomatic vasovagal patients: the heart rhythm observed during a spontaneous syncope is identical to the recurrent syncope but not correlated with the head-up tilt test or ATP test","volume":"47","author":"Deharo","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ancard.2012.08.033_bib0160","doi-asserted-by":"crossref","first-page":"1535","DOI":"10.1093\/eurheartj\/ehr071","article-title":"The management of syncope in patients with bundle branch block: a multi-center, prospective observational study","volume":"32","author":"Moya","year":"2011","journal-title":"Eur Heart J"},{"key":"10.1016\/j.ancard.2012.08.033_bib0120","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1016\/j.eupc.2004.08.008","article-title":"Guidelines on management (diagnosis and treatment) of syncope\u00a0\u2013\u00a0Update 2004","volume":"6","author":"Brignole","year":"2004","journal-title":"Europace"},{"key":"10.1016\/j.ancard.2012.08.033_bib0125","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1093\/eurheartj\/ehi602","article-title":"The clinical impact of implantable loop recorders in patients with syncope","volume":"27","author":"Farwell","year":"2006","journal-title":"Eur Heart J"},{"key":"10.1016\/j.ancard.2012.08.033_bib0130","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1161\/01.CIR.104.1.46","article-title":"Randomized assessment of syncope trial. Conventional diagnostic testing versus a prolonged monitoring strategy","volume":"104","author":"Krahn","year":"2001","journal-title":"Circulation"},{"key":"10.1016\/j.ancard.2012.08.033_bib0135","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1023\/B:JICE.0000019268.95018.91","article-title":"Arrhythmia detection by patient and autoactivation in implantable loop recorders","volume":"10","author":"Ng","year":"2004","journal-title":"J Interv Card Electrophysiol"},{"key":"10.1016\/j.ancard.2012.08.033_bib0140","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1053\/eupc.2002.0301","article-title":"Sensing issues related to the clinical use of implantable loop recorders","volume":"5","author":"Chrysostomakis","year":"2003","journal-title":"Europace"},{"key":"10.1016\/j.ancard.2012.08.033_bib0145","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1111\/j.1540-8159.2004.00502.x","article-title":"Insertable loop recorder use for detection of intermittent arrhythmias","volume":"27","author":"Krahn","year":"2004","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.ancard.2012.08.033_bib0150","doi-asserted-by":"crossref","first-page":"1306","DOI":"10.1016\/j.hrthm.2006.07.018","article-title":"Digital implantable loop recorders in the investigation of syncope in children: benefits and limitations","volume":"3","author":"Kothari","year":"2006","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.ancard.2012.08.033_bib0155","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1053\/eupc.2002.0229","article-title":"Implantable loop recorder undersensing mimicking complete heart block","volume":"4","author":"Chrysostomakis","year":"2002","journal-title":"Europace"}],"container-title":["Annales de Cardiologie et d'Ang\u00e9iologie"],"original-title":[],"language":"fr","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003392812001163?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003392812001163?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,12]],"date-time":"2025-09-12T22:36:45Z","timestamp":1757716605000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0003392812001163"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,11]]},"references-count":31,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2012,11]]}},"alternative-id":["S0003392812001163"],"URL":"https:\/\/doi.org\/10.1016\/j.ancard.2012.08.033","relation":{},"ISSN":["0003-3928"],"issn-type":[{"type":"print","value":"0003-3928"}],"subject":[],"published":{"date-parts":[[2012,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Suivi \u00e0 long terme apr\u00e8s pose de holter implantable pour syncope\u00a0: r\u00e9sultats d\u2019un registre men\u00e9 dans un centre hospitalier","name":"articletitle","label":"Article Title"},{"value":"Annales de Cardiologie et d'Ang\u00e9iologie","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ancard.2012.08.033","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2012 Elsevier Masson SAS. All rights reserved.","name":"copyright","label":"Copyright"}]}}