{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T04:22:13Z","timestamp":1793074933055,"version":"4.5.0"},"reference-count":37,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2018,12,1]],"date-time":"2018-12-01T00:00:00Z","timestamp":1543622400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","annemergmed.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Annals of Emergency Medicine"],"published-print":{"date-parts":[[2018,12]]},"DOI":"10.1016\/j.annemergmed.2018.06.024","type":"journal-article","created":{"date-parts":[[2018,8,14]],"date-time":"2018-08-14T14:12:20Z","timestamp":1534255940000},"page":"627-636","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":119,"title":["Ultrasonography for the Confirmation of Endotracheal Tube Intubation: A Systematic Review and Meta-Analysis"],"prefix":"10.1016","volume":"72","author":[{"given":"Michael","family":"Gottlieb","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dallas","family":"Holladay","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gary D.","family":"Peksa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.annemergmed.2018.06.024_bib1","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1016\/j.annemergmed.2014.10.036","article-title":"Techniques, success, and adverse events of emergency department adult intubations","volume":"65","author":"Brown","year":"2015","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib2","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1093\/bja\/73.1.55","article-title":"Accidental oesophageal intubation","volume":"73","author":"Clyburn","year":"1994","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib3","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1016\/S0196-0644(98)70204-5","article-title":"Use of tube condensation as an indicator of endotracheal tube placement","volume":"31","author":"Kelly","year":"1998","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib4","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/S0196-0644(05)80937-0","article-title":"Verification of endotracheal tube placement with colorimetric end-tidal CO2 detection","volume":"20","author":"MacLeod","year":"1991","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib5","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/S0300-9572(02)00345-3","article-title":"The assessment of three methods to verify tracheal tube placement in the emergency setting","volume":"56","author":"Takeda","year":"2003","journal-title":"Resuscitation"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib6","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1016\/j.jemermed.2006.08.022","article-title":"Transtracheal 2-d ultrasound for identification of esophageal intubation","volume":"32","author":"Milling","year":"2007","journal-title":"J\u00a0Emerg Med"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib7","doi-asserted-by":"crossref","first-page":"1432","DOI":"10.1097\/00000542-200012000-00015","article-title":"Accuracy and reliability of the self-inflating bulb to verify tracheal intubation in out-of-hospital cardiac arrest patients","volume":"93","author":"Tanigawa","year":"2000","journal-title":"Anesthesiology"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib8","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1213\/00000539-200102000-00018","article-title":"The efficacy of esophageal detector devices in verifying tracheal tube placement: a randomized cross-over study of out-of-hospital cardiac arrest patients","volume":"92","author":"Tanigawa","year":"2001","journal-title":"Anesth Analg"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib9","doi-asserted-by":"crossref","first-page":"264","DOI":"10.7326\/0003-4819-151-4-200908180-00135","article-title":"Preferred Reporting Items for Systematic Reviews and Meta-analyses: the PRISMA statement","volume":"151","author":"Moher","year":"2009","journal-title":"Ann Intern Med"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib10","doi-asserted-by":"crossref","first-page":"529","DOI":"10.7326\/0003-4819-155-8-201110180-00009","article-title":"QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies","volume":"155","author":"Whiting","year":"2011","journal-title":"Ann Intern Med"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib11","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.1126\/science.3287615","article-title":"Measuring the accuracy of diagnostic systems","volume":"240","author":"Swets","year":"1988","journal-title":"Science"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib12","doi-asserted-by":"crossref","first-page":"882","DOI":"10.1016\/j.jclinepi.2005.01.016","article-title":"The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed","volume":"58","author":"Deeks","year":"2005","journal-title":"J\u00a0Clin Epidemiol"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib13","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/j.annemergmed.2006.07.004","article-title":"Pilot study to evaluate the accuracy of ultrasonography in confirming endotracheal tube placement","volume":"49","author":"Werner","year":"2007","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib14","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1055\/s-0034-1366014","article-title":"Bedside ultrasound of the neck confirms endotracheal tube position in emergency intubations","volume":"35","author":"Hoffmann","year":"2014","journal-title":"Ultraschall Med"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib15","doi-asserted-by":"crossref","first-page":"2079","DOI":"10.1002\/jum.14231","article-title":"A\u00a0prospective evaluation of transverse tracheal sonography during emergent intubation by emergency medicine resident physicians","volume":"36","author":"Lahham","year":"2017","journal-title":"J\u00a0Ultrasound Med"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib16","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1097\/MEJ.0000000000000108","article-title":"Direct ultrasound methods: a confirmatory technique for proper endotracheal intubation in the emergency department","volume":"22","author":"Abbasi","year":"2015","journal-title":"Eur J Emerg Med"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib17","doi-asserted-by":"crossref","first-page":"618","DOI":"10.3889\/oamjms.2017.072","article-title":"Predictive value of tracheal rapid ultrasound exam performed in the emergency department for verification of tracheal intubation","volume":"5","author":"Masoumi","year":"2017","journal-title":"Open Access Maced J Med Sci"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib18","first-page":"e19","article-title":"Screening characteristics of bedside ultrasonography in confirming endotracheal tube placement: a diagnostic accuracy study","volume":"5","author":"Zamani Moghadam","year":"2017","journal-title":"Emerg (Tehran)"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib19","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.1016\/j.resuscitation.2011.05.016","article-title":"Tracheal rapid ultrasound exam (T.R.U.E.) for confirming endotracheal tube placement during emergency intubation","volume":"82","author":"Chou","year":"2011","journal-title":"Resuscitation"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib20","doi-asserted-by":"crossref","first-page":"1708","DOI":"10.1016\/j.resuscitation.2013.06.018","article-title":"Real-time tracheal ultrasonography for confirmation of endotracheal tube placement during cardiopulmonary resuscitation","volume":"84","author":"Chou","year":"2013","journal-title":"Resuscitation"},{"issue":"suppl 1","key":"10.1016\/j.annemergmed.2018.06.024_bib21","doi-asserted-by":"crossref","first-page":"A29","DOI":"10.1186\/2036-7902-6-S1-A29","article-title":"Ultrasonography for proper endotracheal tube placement confirmation in out-of-hospital cardiac arrest patients: two-center experience","volume":"6","author":"Sun","year":"2014","journal-title":"Crit Ultrasound J"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib22","doi-asserted-by":"crossref","first-page":"671","DOI":"10.7863\/jum.2011.30.5.671","article-title":"Use of sonography for rapid identification of esophageal and tracheal intubations in adult patients","volume":"30","author":"Muslu","year":"2011","journal-title":"J\u00a0Ultrasound Med"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib23","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1016\/j.ajem.2012.08.002","article-title":"Confirmation of endotracheal tube position during resuscitation by bedside ultrasonography","volume":"31","author":"Sa\u011flam","year":"2013","journal-title":"Am J Emerg Med"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib24","doi-asserted-by":"crossref","first-page":"486","DOI":"10.4103\/ija.IJA_544_16","article-title":"End-tidal capnography and upper airway ultrasonography in the rapid confirmation of endotracheal tube placement in patients requiring intubation for general anaesthesia","volume":"61","author":"Abhishek","year":"2017","journal-title":"Indian J Anaesth"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib25","doi-asserted-by":"crossref","first-page":"257","DOI":"10.4103\/ijccm.IJCCM_417_16","article-title":"Reliability of ultrasonography in confirming endotracheal tube placement in an emergency setting","volume":"21","author":"Thomas","year":"2017","journal-title":"Indian J Crit Care Med"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib26","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1111\/j.1742-6723.2009.01199.x","article-title":"Confirmation of endotracheal intubation by combined ultrasonographic methods in the emergency department","volume":"21","author":"Park","year":"2009","journal-title":"Emerg Med Australas"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib27","first-page":"10143","article-title":"The sensitivity and specificity of ultrasonic localization of endotracheal intubation","volume":"10","author":"Yang","year":"2017","journal-title":"Int J Clin Exp Med"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib28","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1186\/2036-7902-5-7","article-title":"A\u00a0feasibility study on bedside upper airway ultrasonography compared to waveform capnography for verifying endotracheal tube location after intubation","volume":"5","author":"Adi","year":"2013","journal-title":"Crit Ultrasound J"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib29","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1186\/s13089-015-0031-7","article-title":"Defining the learning curve of point-of-care ultrasound for confirming endotracheal tube placement by emergency physicians","volume":"7","author":"Chenkin","year":"2015","journal-title":"Crit Ultrasound J"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib30","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/S0736-4679(00)00318-8","article-title":"Capnography alone is imperfect for endotracheal tube placement confirmation during emergency intubation","volume":"20","author":"Li","year":"2001","journal-title":"J\u00a0Emerg Med"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib31","doi-asserted-by":"crossref","first-page":"1190","DOI":"10.1111\/j.1399-6576.2011.02501.x","article-title":"Temporal comparison of ultrasound vs auscultation and capnography in verification of endotracheal tube placement","volume":"55","author":"Pfeiffer","year":"2011","journal-title":"Acta Anaesthesiol Scand"},{"issue":"16 suppl 1","key":"10.1016\/j.annemergmed.2018.06.024_bib32","doi-asserted-by":"crossref","first-page":"S84","DOI":"10.1161\/CIR.0000000000000273","article-title":"Part 4: advanced life support: 2015 International consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations","volume":"132","author":"Callaway","year":"2015","journal-title":"Circulation"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib33","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1007\/s12630-014-0301-z","article-title":"Transtracheal ultrasound for verification of endotracheal tube placement: a systematic review and meta-analysis","volume":"62","author":"Das","year":"2015","journal-title":"Can J Anaesth"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib34","doi-asserted-by":"crossref","first-page":"834","DOI":"10.5811\/westjem.22550.9.22550","article-title":"Accuracy of a novel ultrasound technique for confirmation of endotracheal intubation by expert and novice emergency physicians","volume":"15","author":"Gottlieb","year":"2014","journal-title":"West J Emerg Med"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib35","doi-asserted-by":"crossref","first-page":"412","DOI":"10.5811\/westjem.2017.12.36714","article-title":"Comparison of static versus dynamic ultrasound for the detection of endotracheal intubation","volume":"19","author":"Gottlieb","year":"2018","journal-title":"West J Emerg Med"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib36","doi-asserted-by":"crossref","unstructured":"Gottlieb M, Holladay D, Serici A, et\u00a0al. Comparison of color flow with standard ultrasound for the detection of endotracheal intubation. Am J Emerg Med. 2018;36:1166-1169.","DOI":"10.1016\/j.ajem.2017.11.056"},{"key":"10.1016\/j.annemergmed.2018.06.024_bib37","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/j.resuscitation.2015.02.013","article-title":"Ultrasonography for confirmation of endotracheal tube placement: a systematic review and meta-analysis","volume":"90","author":"Chou","year":"2015","journal-title":"Resuscitation"}],"container-title":["Annals of Emergency Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0196064418305559?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0196064418305559?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,7,9]],"date-time":"2024-07-09T06:39:32Z","timestamp":1720507172000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0196064418305559"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12]]},"references-count":37,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2018,12]]}},"alternative-id":["S0196064418305559"],"URL":"https:\/\/doi.org\/10.1016\/j.annemergmed.2018.06.024","relation":{},"ISSN":["0196-0644"],"issn-type":[{"value":"0196-0644","type":"print"}],"subject":[],"published":{"date-parts":[[2018,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Ultrasonography for the Confirmation of Endotracheal Tube Intubation: A Systematic Review and Meta-Analysis","name":"articletitle","label":"Article Title"},{"value":"Annals of Emergency Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.annemergmed.2018.06.024","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 by the American College of Emergency Physicians.","name":"copyright","label":"Copyright"}]}}