{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T16:59:09Z","timestamp":1782406749969,"version":"3.54.5"},"reference-count":36,"publisher":"AVES YAYINCILIK A.\u015e.","issue":"1","license":[{"start":{"date-parts":[[2020,2,7]],"date-time":"2020-02-07T00:00:00Z","timestamp":1581033600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2016,11,1]],"date-time":"2016-11-01T00:00:00Z","timestamp":1477958400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["AOTT"],"abstract":"<jats:p>Objectives: The aim of the present study was to evaluate results, including clinical and radiological outcomes and number of complications, following minimally invasive plate osteosynthesis (MIPO) of proximal humerus fractures, using the PHILOS\u00ae proximal humerus internal locking system (Synthes Holding AG, Solothurn, Switzerland).\n\nMethods: Retrospectively evaluated were 31 patients treated with MIPO (12 male, 19 female; average age: 58.4 years). Four patients had 2-part fractures, 14 patients had 3-part fractures, and 13 patients had 4-part fractures, according to Neer classification. Healing, complications, and head-shaft angle (HSA) were radiographically evaluated. Clinical outcomes were assessed at 1-year follow-up with Constant score.\n\nResults: Average Constant scores for fractured and normal shoulders were 73.2 \u00b1 10.9 and 84.8 \u00b1 5.1, respectively. Varus progression, fracture type, and age had no significant effect on functional outcome. Average postoperative and follow-up HSA's were 130.80 \u00b1 7.70 and 128.80 \u00b1 10.00, respectively. Significant varus progression was observed during follow-up (p &amp;frac14; 0.01). Varus progression was more prominent in patients with postoperative HSA &lt; 130 (p &lt; 0.001). Inferomedial calcar screw usage, fracture type, and age had no significant effect on varus progression. Complications included 2 implant failures, 1 case of avascular necrosis (AVN), 1 primary screw cut-out, 1 axillary nerve injury, and 1 radial nerve injury (22.6% overall).\n\nConclusion: MIPO is a safe and effective option for the treatment of proximal humerus fractures, with good functional recovery and fewer complications, which are typically technique dependent. Reduction may be difficult, resulting in varus progression. Another disadvantage is risk of axillary nerve injury. Careful surgical technique and correct implant selection is important in the prevention of nerve injury. Level of evidence:\n\nLevel IV, Therapeutic study.<\/jats:p>","DOI":"10.1016\/j.aott.2016.10.003","type":"journal-article","created":{"date-parts":[[2016,11,18]],"date-time":"2016-11-18T04:46:12Z","timestamp":1479444372000},"page":"17-22","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":23,"title":["Minimally invasive plate osteosynthesis with PHILOS plate for proximal humerus fractures"],"prefix":"10.5152","volume":"51","author":[{"given":"U\u011fur","family":"G\u00f6n\u00e7","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mesut","family":"Atabek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kursat","family":"Teker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Altu\u011f","family":"Tanr\u0131\u00f6ver","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"3111","published-online":{"date-parts":[[2020,2,7]]},"reference":[{"key":"10.1016\/j.aott.2016.10.003_bib1","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1097\/01.blo.0000194672.79634.78","article-title":"Update in the epidemiology of proximal humeral fractures","volume":"442","author":"Palvanen","year":"2006","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"10.1016\/j.aott.2016.10.003_bib2","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1016\/j.injury.2010.10.016","article-title":"New trends in fixation of proximal humeral fractures: a review","volume":"42","author":"Karataglis","year":"2011","journal-title":"Injury"},{"issue":"2","key":"10.1016\/j.aott.2016.10.003_bib3","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1007\/s00264-014-2630-5","article-title":"Decision making in displaced fractures of the proximal humerus: fracture or surgeon based?","volume":"39","author":"Gradl","year":"2015","journal-title":"Int Orthop"},{"issue":"6","key":"10.1016\/j.aott.2016.10.003_bib4","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1016\/S1058-2746(03)00217-9","article-title":"Fixed\u2014angle plate fixation in simulated fractures of the proximal humerus: a biomechanical study of a new device","volume":"12","author":"Chudik","year":"2003","journal-title":"J\u00a0Shoulder Elbow Surg"},{"issue":"4","key":"10.1016\/j.aott.2016.10.003_bib5","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1007\/BF00381665","article-title":"Results of surgical treatment of multifragmented fractures of the humeral head","volume":"100","author":"Sturzenegger","year":"1982","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.aott.2016.10.003_bib6","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1097\/01.blo.0000152872.95806.09","article-title":"The extended anterolateral acromial approach allows minimally invasive access to the proximal humerus","volume":"434","author":"Gardner","year":"2005","journal-title":"Clin Orthop Relat Res"},{"issue":"7","key":"10.1016\/j.aott.2016.10.003_bib7","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1097\/BOT.0b013e3181ccafb3","article-title":"Clinical results for minimally invasive locked plating of proximal humerus fractures","volume":"24","author":"R\u00f6derer","year":"2010","journal-title":"J\u00a0Orthop Trauma"},{"issue":"6","key":"10.1016\/j.aott.2016.10.003_bib8","first-page":"1737","article-title":"Minimally invasive polyaxial locking plate fixation of proximal humeral fractures: a prospective study","volume":"71","author":"Ruchholtz","year":"2011","journal-title":"J\u00a0Trauma"},{"issue":"4","key":"10.1016\/j.aott.2016.10.003_bib9","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1016\/j.injury.2012.09.010","article-title":"A\u00a0prospective analysis of the functional and radiological outcomes of minimally invasive plating in proximal humerus fractures","volume":"44","author":"Acklin","year":"2013","journal-title":"Injury"},{"issue":"1","key":"10.1016\/j.aott.2016.10.003_bib10","doi-asserted-by":"crossref","first-page":"66","DOI":"10.4055\/cios.2013.5.1.66","article-title":"Indirect reduction maneuver and minimally invasive approach for displaced proximal humerus fractures in elderly patients","volume":"5","author":"Jung","year":"2013","journal-title":"Clin Orthop Surg"},{"issue":"9","key":"10.1016\/j.aott.2016.10.003_bib11","doi-asserted-by":"crossref","first-page":"1334","DOI":"10.1016\/j.jse.2013.12.018","article-title":"Minimally invasive plate osteosynthesis for proximal humeral fractures: clinical and radiologic outcomes according to fracture type","volume":"23","author":"Sohn","year":"2014","journal-title":"J\u00a0Shoulder Elbow Surg"},{"issue":"2","key":"10.1016\/j.aott.2016.10.003_bib12","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1177\/230949901502300208","article-title":"Minimally invasive plate osteosynthesis for proximal humeral fractures","volume":"23","author":"Koljonen","year":"2015","journal-title":"J\u00a0Orthop Surg (Hong Kong)"},{"issue":"2","key":"10.1016\/j.aott.2016.10.003_bib13","doi-asserted-by":"crossref","first-page":"146","DOI":"10.4055\/cios.2014.6.2.146","article-title":"Complications and outcomes of minimally invasive percutaneous plating for proximal humeral fractures","volume":"6","author":"Park","year":"2014","journal-title":"Clin Orthop Surg"},{"key":"10.1016\/j.aott.2016.10.003_bib14","doi-asserted-by":"crossref","first-page":"971216","DOI":"10.1155\/2015\/971216","article-title":"Minimal invasive percutaneous osteosynthesis for elderly valgus impacted proximal humeral fractures with the PHILOS","volume":"2015","author":"Chen","year":"2015","journal-title":"Biomed Res Int"},{"issue":"3","key":"10.1016\/j.aott.2016.10.003_bib15","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1007\/s00264-015-3069-z","article-title":"Minimally invasive plate osteosynthesis in proximal humeral fractures: 1\u2014year results of a prospective multicenter study","volume":"40","author":"Falez","year":"2016","journal-title":"Int Orthop"},{"issue":"3","key":"10.1016\/j.aott.2016.10.003_bib16","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1097\/BOT.0b013e3180333094","article-title":"The importance of medial support in locked plating of proximal humerus fractures","volume":"21","author":"Gardner","year":"2007","journal-title":"J\u00a0Orthop Trauma"},{"issue":"4","key":"10.1016\/j.aott.2016.10.003_bib17","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1067\/mse.2002.124429","article-title":"Geometry of the proximal humerus and implications for prosthetic design","volume":"11","author":"Hertel","year":"2002","journal-title":"J\u00a0Shoulder Elbow Surg"},{"issue":"9","key":"10.1016\/j.aott.2016.10.003_bib18","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1097\/01.bot.0000246412.10176.14","article-title":"Vascular implications of minimally invasive plating of proximal humerus fractures","volume":"20","author":"Gardner","year":"2006","journal-title":"J\u00a0Orthop Trauma"},{"issue":"7","key":"10.1016\/j.aott.2016.10.003_bib19","doi-asserted-by":"crossref","first-page":"999","DOI":"10.1016\/j.injury.2011.08.025","article-title":"Benefits and harms of locking plate osteosynthesis in intraarticular (OTA Type C) fractures of the proximal humerus: a systematic review","volume":"43","author":"Brorson","year":"2012","journal-title":"Injury"},{"key":"10.1016\/j.aott.2016.10.003_bib20","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1186\/1471-2474-15-206","article-title":"Minimally invasive plate osteosynthesis with a locking compression plate is superior to open reduction and internal fixation in the management of the proximal humerus fractures","volume":"15","author":"Lin","year":"2014","journal-title":"BMC Musculoskelet Disord"},{"key":"10.1016\/j.aott.2016.10.003_bib21","doi-asserted-by":"crossref","first-page":"496","DOI":"10.12659\/MSM.893323","article-title":"Advantage of minimally invasive lateral approach relative to conventional deltopectoral approach for treatment of proximal humerus fractures","volume":"21","author":"Liu","year":"2015","journal-title":"Med Sci Monit"},{"issue":"2","key":"10.1016\/j.aott.2016.10.003_bib22","doi-asserted-by":"crossref","first-page":"97","DOI":"10.3944\/AOTT.2010.2275","article-title":"Locking plate fixation of 3\u2014 and 4\u2014part proximal humeral fractures","volume":"44","author":"Parmaksizo\u011flu","year":"2010","journal-title":"Acta Orthop Traumatol Turc"},{"issue":"2","key":"10.1016\/j.aott.2016.10.003_bib23","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.injury.2006.08.025","article-title":"Percutaneous insertion of a proximal humeral locking plate: an anatomic study","volume":"38","author":"Smith","year":"2007","journal-title":"Injury"},{"issue":"10","key":"10.1016\/j.aott.2016.10.003_bib24","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1016\/j.injury.2010.04.014","article-title":"Risk of axillary nerve injury during percutaneous proximal humerus locking plate insertion using an external aiming guide","volume":"41","author":"Saran","year":"2010","journal-title":"Injury"},{"issue":"1","key":"10.1016\/j.aott.2016.10.003_bib25","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1007\/s00064-011-0051-9","article-title":"Plate fixation of proximal humerus fractures using the minimally invasive anterolateral delta split approach","volume":"24","author":"Acklin","year":"2012","journal-title":"Oper Orthop Traumatol"},{"issue":"1","key":"10.1016\/j.aott.2016.10.003_bib26","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.otsr.2008.09.003","article-title":"Proximal humerus fractures treated by percutaneous locking plate internal fixation","volume":"95","author":"Rouleau","year":"2009","journal-title":"Orthop Traumatol Surg Res"},{"issue":"5","key":"10.1016\/j.aott.2016.10.003_bib27","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1302\/0301-620X.92B5.22849","article-title":"Proximal humeral fractures with a severe varus deformity treated by fixation with a locking plate","volume":"92","author":"Robinson","year":"2010","journal-title":"J\u00a0Bone Jt Surg Br"},{"issue":"1","key":"10.1016\/j.aott.2016.10.003_bib28","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.jse.2008.06.014","article-title":"Prognostic factors for unstable proximal humeral fractures treated with locking\u2014plate fixation","volume":"18","author":"Lee","year":"2009","journal-title":"J\u00a0Shoulder Elbow Surg"},{"issue":"5","key":"10.1016\/j.aott.2016.10.003_bib29","first-page":"1235","article-title":"The biomechanics of locked plating for repairing proximal humerus fractures with or without medial cortical support","volume":"69","author":"Lescheid","year":"2010","journal-title":"J\u00a0Trauma"},{"key":"10.1016\/j.aott.2016.10.003_bib30","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1186\/1471-2474-14-102","article-title":"Does medial support decrease major complications of unstable proximal humerus fractures treated with locking plate?","volume":"14","author":"Jung","year":"2013","journal-title":"BMC Musculoskelet Disord"},{"issue":"11","key":"10.1016\/j.aott.2016.10.003_bib31","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1007\/s00264-011-1227-5","article-title":"The clinical benefit of medial support screws in locking plating of proximal humerus fractures: a prospective randomized study","volume":"35","author":"Zhang","year":"2011","journal-title":"Int Orthop"},{"issue":"3","key":"10.1016\/j.aott.2016.10.003_bib32","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1097\/BOT.0b013e31815b3922","article-title":"Indirect medial reduction and strut support of proximal humerus fractures using an endosteal implant","volume":"22","author":"Gardner","year":"2008","journal-title":"J\u00a0Orthop Trauma"},{"issue":"11","key":"10.1016\/j.aott.2016.10.003_bib33","doi-asserted-by":"crossref","first-page":"1939","DOI":"10.1016\/j.injury.2012.08.004","article-title":"Locking plate and fibular allograft augmentation in unstable fractures of proximal humerus","volume":"43","author":"Matassi","year":"2012","journal-title":"Injury"},{"issue":"5","key":"10.1016\/j.aott.2016.10.003_bib34","doi-asserted-by":"crossref","first-page":"553","DOI":"10.3944\/AOTT.2014.13.0083","article-title":"Relationship between axillary nerve and percutaneously inserted proximal humeral locking plate: a cadaver study","volume":"48","author":"Esenyel","year":"2014","journal-title":"Acta Orthop Traumatol Turc"},{"issue":"1\u20142","key":"10.1016\/j.aott.2016.10.003_bib35","first-page":"18","article-title":"A\u00a0minimally invasive approach for plate fixation of the proximal humerus","volume":"62","author":"Gardner","year":"2004","journal-title":"Bull Hosp Jt Dis"},{"issue":"3","key":"10.1016\/j.aott.2016.10.003_bib36","doi-asserted-by":"crossref","first-page":"154","DOI":"10.3944\/AOTT.2012.2592","article-title":"Minimally invasive plate osteosynthesis (MIPO) in diaphyseal humerus and proximal humerus fractures","volume":"46","author":"Aksu","year":"2012","journal-title":"Acta Orthop Traumatol Turc"}],"container-title":["Acta Orthopaedica et Traumatologica Turcica"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1017995X16302590?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1017995X16302590?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aott.org.tr\/index.php\/pub\/article\/download\/3217\/3165","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,18]],"date-time":"2025-11-18T11:06:04Z","timestamp":1763463964000},"score":1,"resource":{"primary":{"URL":"https:\/\/aott.org.tr\/index.php\/pub\/article\/view\/3217"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,7]]},"references-count":36,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,1,1]]}},"URL":"https:\/\/doi.org\/10.1016\/j.aott.2016.10.003","relation":{},"ISSN":["2589-1294","1017-995X"],"issn-type":[{"value":"2589-1294","type":"electronic"},{"value":"1017-995X","type":"print"}],"subject":[],"published":{"date-parts":[[2020,2,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Minimally invasive plate osteosynthesis with PHILOS plate for proximal humerus fractures","name":"articletitle","label":"Article Title"},{"value":"Acta Orthopaedica et Traumatologica Turcica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.aott.2016.10.003","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Turkish Association of Orthopaedics and Traumatology. Publishing services by Elsevier B.V.","name":"copyright","label":"Copyright"}]}}