{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T13:56:43Z","timestamp":1787061403595,"version":"build-2736575974"},"reference-count":15,"publisher":"AVES YAYINCILIK A.\u015e.","issue":"6","license":[{"start":{"date-parts":[[2020,2,6]],"date-time":"2020-02-06T00:00:00Z","timestamp":1580947200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,2,28]],"date-time":"2017-02-28T00:00:00Z","timestamp":1488240000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["AOTT"],"abstract":"<jats:p>Abstract\n\n\nThe aim of this study was to compare the efficiency of dorsal tangential fluoroscopy and ultrasonography in detecting dorsal screw penetration in distal radius volar locking plate applications. Ten cadaveric forearms were operated. The distal four screws were protruded 0, 1 and 2?mm into each of the second, third and fourth dorsal compartments of distal radius. Dorsal horizon views were taken using fluoroscopy. Each radiographic image was evaluated by two orthopedic surgeons who are blinded to procedure. Sonographic evaluations were performed by an orthopedic surgeon blinded to the procedure. Both dorsal horizon view and ultrasonography assessments were noted by the evaluators whether the tip of the screw penetrated or not the dorsal cortex for each compartment. No significant difference was observed on correct detection of 0?mm, 1?mm and 2?mm screw penetrations at second and third compartments. In the fourth compartment, there was no difference with 0?mm and 2?mm penetrations but correct detection accuracy of 1?mm screw penetration was 87% in ultrasonography group and 71% in dorsal horizon view group. The accuracy of ultrasonography on 1?mm penetration at the fourth compartment is better than dorsal horizon view. However, dorsal horizon view and ultrasonography accuracy is similar for the other compartments and penetration levels. Ultrasonography is a reliable and effective procedure for detection of dorsal screw penetrations. Level III, Diagnostic study.\nER -\n\n \n\nKeywords\n\n \n\n\n\tDistal radius fracture\n\tVolar plating\n\tComplications\n\tUltrasound\n\tTendon rupture<\/jats:p>","DOI":"10.1016\/j.aott.2017.10.004","type":"journal-article","created":{"date-parts":[[2017,11,1]],"date-time":"2017-11-01T05:47:31Z","timestamp":1509515251000},"page":"448-450","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":14,"title":["Comparison of ultrasound and dorsal horizon radiographic view for the detection of dorsal screw penetration"],"prefix":"10.5152","volume":"51","author":[{"given":"Yusuf","family":"GURBUZ","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Levent","family":"KUCUK","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huseyin","family":"GUNAY","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kemal","family":"OZAKSAR","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tahir","family":"Sadik SUGUN","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Okan","family":"B\u0130LGE","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"3111","published-online":{"date-parts":[[2020,2,6]]},"reference":[{"key":"10.1016\/j.aott.2017.10.004_bib1","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1142\/S0218810400000223","article-title":"The treatment of unstable distal radius fractures with volar fixation","volume":"5","author":"Orbay","year":"2000","journal-title":"Hand Surg"},{"key":"10.1016\/j.aott.2017.10.004_bib2","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1053\/jhsu.2002.32081","article-title":"Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report","volume":"27","author":"Orbay","year":"2002","journal-title":"J\u00a0Hand Surg"},{"key":"10.1016\/j.aott.2017.10.004_bib3","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1016\/j.injury.2013.01.008","article-title":"Complications of distal radius locking plates","volume":"44","author":"Toros","year":"2013","journal-title":"Injury"},{"key":"10.1016\/j.aott.2017.10.004_bib4","doi-asserted-by":"crossref","first-page":"22","DOI":"10.3944\/AOTT.2012.2623","article-title":"Results of volar locking plating for unstable distal radius fractures","volume":"46","author":"Sugun","year":"2012","journal-title":"Acta Orthop Traumatol Turc"},{"key":"10.1016\/j.aott.2017.10.004_bib5","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1177\/1753193410392869","article-title":"Screw prominences related to palmar locking plating of distal radius","volume":"36","author":"Sugun","year":"2011","journal-title":"J\u00a0Hand Surg Eur Vol"},{"key":"10.1016\/j.aott.2017.10.004_bib6","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1097\/01.blo.0000223998.02765.0d","article-title":"Two potential causes of EPL rupture after distal radius volar plate flexion","volume":"451","author":"Benson","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.aott.2017.10.004_bib7","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1007\/s11552-010-9316-2","article-title":"Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating","volume":"6","author":"Ozer","year":"2011","journal-title":"Hand (N Y)"},{"key":"10.1016\/j.aott.2017.10.004_bib8","doi-asserted-by":"crossref","first-page":"1101","DOI":"10.1302\/0301-620X.95B8.31301","article-title":"A\u00a0new radiological method to detect dorsally penetrating screws when using volar locking plates in distal radial fractures: the dorsal horizon view","volume":"95","author":"Haug","year":"2013","journal-title":"Bone Joint J"},{"key":"10.1016\/j.aott.2017.10.004_bib9","doi-asserted-by":"crossref","first-page":"1691","DOI":"10.1016\/j.jhsa.2011.07.020","article-title":"The dorsal horizon view: detecting screw protrusion at the distal radius","volume":"36","author":"Joseph","year":"2011","journal-title":"J\u00a0Hand Surg Am"},{"key":"10.1016\/j.aott.2017.10.004_bib10","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1007\/s11552-007-9038-2","article-title":"Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study","volume":"2","author":"Maschke","year":"2007","journal-title":"Hand (N Y)"},{"key":"10.1016\/j.aott.2017.10.004_bib11","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1016\/j.jhsa.2012.02.026","article-title":"Comparison of 4 fluoroscopic views for dorsal cortex screw penetration after volar plating of the distal radius","volume":"37","author":"Ozer","year":"2012","journal-title":"J\u00a0Hand Surg Am"},{"key":"10.1016\/j.aott.2017.10.004_bib12","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.jhsa.2014.10.021","article-title":"The dorsal tangential X-ray view to determine dorsal screw penetration during volar plating of distal radius fractures","volume":"40","author":"Brunner","year":"2015","journal-title":"J\u00a0Hand Surg Am"},{"key":"10.1016\/j.aott.2017.10.004_bib13","doi-asserted-by":"crossref","first-page":"598","DOI":"10.1177\/1753193409101471","article-title":"Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis","volume":"34","author":"Pichler","year":"2009","journal-title":"J\u00a0Hand Surg Eur Vol"},{"key":"10.1016\/j.aott.2017.10.004_bib14","doi-asserted-by":"crossref","first-page":"1716","DOI":"10.1016\/j.jhsa.2008.08.012","article-title":"Morphometric analysis of Lister's tubercle and its consequences on volar plate fixation of distal radius fractures","volume":"33","author":"Clement","year":"2008","journal-title":"J\u00a0Hand Surg Am"},{"key":"10.1016\/j.aott.2017.10.004_bib15","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1177\/1753193411426809","article-title":"Accuracy of the skyline view for detecting dorsal cortical penetration during volar distal radius fixation","volume":"37","author":"Riddick","year":"2012","journal-title":"J\u00a0Hand Surg Eur Vol"}],"container-title":["Acta Orthopaedica et Traumatologica Turcica"],"original-title":[],"link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1017995X17301256?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1017995X17301256?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aott.org.tr\/index.php\/pub\/article\/download\/3304\/3251","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,18]],"date-time":"2025-11-18T11:45:40Z","timestamp":1763466340000},"score":1,"resource":{"primary":{"URL":"https:\/\/aott.org.tr\/index.php\/pub\/article\/view\/3304"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,6]]},"references-count":15,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2017,1,6]]}},"URL":"https:\/\/doi.org\/10.1016\/j.aott.2017.10.004","relation":{},"ISSN":["2589-1294","1017-995X"],"issn-type":[{"value":"2589-1294","type":"electronic"},{"value":"1017-995X","type":"print"}],"subject":[],"published":{"date-parts":[[2020,2,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of ultrasound and dorsal horizon radiographic view for the detection of dorsal screw penetration","name":"articletitle","label":"Article Title"},{"value":"Acta Orthopaedica et Traumatologica Turcica","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.aott.2017.10.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Turkish Association of Orthopaedics and Traumatology. Publishing services by Elsevier B.V.","name":"copyright","label":"Copyright"}]}}