{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T12:52:53Z","timestamp":1791291173605,"version":"4.3.0"},"reference-count":42,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2027,4,1]],"date-time":"2027-04-01T00:00:00Z","timestamp":1806537600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2027,4,1]],"date-time":"2027-04-01T00:00:00Z","timestamp":1806537600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T00:00:00Z","timestamp":1791158400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Applied Ergonomics"],"published-print":{"date-parts":[[2027,4]]},"DOI":"10.1016\/j.apergo.2026.104902","type":"journal-article","created":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T07:55:16Z","timestamp":1791273316000},"page":"104902","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["A supervised machine learning approach to predict core temperature for workers with high-level personal protective equipment"],"prefix":"10.1016","volume":"140","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5026-9548","authenticated-orcid":false,"given":"Cory J.","family":"Coehoorn","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-6824-4067","authenticated-orcid":false,"given":"Cory J.","family":"Fernandes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammed","family":"Alomani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-6687-0196","authenticated-orcid":false,"given":"Parker","family":"Townsend","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-0506-7814","authenticated-orcid":false,"given":"Hannah","family":"Cowart","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-6207-3757","authenticated-orcid":false,"given":"James","family":"Lalonde","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.apergo.2026.104902_bib1","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-023-49929-x","article-title":"Validity of heart rate derived core temperature estimation during simulated firefighting tasks","volume":"13","author":"Agostinelli","year":"2023","journal-title":"Sci. Rep."},{"issue":"3","key":"10.1016\/j.apergo.2026.104902_bib2","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.tjem.2018.08.001","article-title":"User's guide to correlation coefficients","volume":"18","author":"Akoglu","year":"2018","journal-title":"Turk. J. Emerg. Med."},{"key":"10.1016\/j.apergo.2026.104902_bib3","series-title":"Exertional Heat Illness","author":"Armstrong","year":"2003"},{"issue":"25","key":"10.1016\/j.apergo.2026.104902_bib4","doi-asserted-by":"crossref","first-page":"1978","DOI":"10.1056\/NEJMra011089","article-title":"Heat stroke","volume":"346","author":"Bouchama","year":"2002","journal-title":"N. Engl. J. Med."},{"issue":"11","key":"10.1016\/j.apergo.2026.104902_bib5","doi-asserted-by":"crossref","first-page":"1830","DOI":"10.1080\/00140139.2015.1036792","article-title":"Real-time core body temperature estimation from heart rate for first responders wearing different levels of personal protective equipment","volume":"58","author":"Buller","year":"2015","journal-title":"Ergonomics"},{"issue":"3","key":"10.1016\/j.apergo.2026.104902_bib6","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1136\/bjsm.2006.026344","article-title":"The ingestible telemetric body core temperature sensor: a review of validity and exercise applications","volume":"41","author":"Byrne","year":"2007","journal-title":"Br. J. Sports Med."},{"key":"10.1016\/j.apergo.2026.104902_bib7","doi-asserted-by":"crossref","first-page":"986","DOI":"10.4085\/1062-6050-50.9.07","article-title":"National athletic trainers' association position statement: exertional heat illnesses","volume":"50","author":"Casa","year":"2015","journal-title":"J. Athl. Train."},{"issue":"5","key":"10.1016\/j.apergo.2026.104902_bib8","doi-asserted-by":"crossref","first-page":"1731","DOI":"10.1152\/jappl.1998.84.5.1731","article-title":"Heat acclimation, aerobic fitness, and hydration effects on tolerance during uncompensable heat stress","volume":"84","author":"Cheung","year":"1998","journal-title":"J. Appl. Physiol."},{"issue":"5","key":"10.1016\/j.apergo.2026.104902_bib9","doi-asserted-by":"crossref","first-page":"329","DOI":"10.2165\/00007256-200029050-00004","article-title":"The thermophysiology of uncompensable heat stress. Physiological manipulations and individual characteristics","volume":"29","author":"Cheung","year":"2000","journal-title":"Sports Med."},{"key":"10.1016\/j.apergo.2026.104902_bib13","series-title":"A Novel Approach to Predict Core Temperature During Heat Stress Among Firefighters","author":"Coehoorn","year":"2024"},{"key":"10.1016\/j.apergo.2026.104902_bib11","doi-asserted-by":"crossref","DOI":"10.1016\/j.jtherbio.2022.103305","article-title":"Firefighter salivary cortisol responses following rapid heat stress","volume":"108","author":"Coehoorn","year":"2022","journal-title":"J. Therm. Biol."},{"key":"10.1016\/j.apergo.2026.104902_bib12","doi-asserted-by":"crossref","DOI":"10.1016\/j.brainres.2022.148156","article-title":"Firefighter pre-frontal cortex oxygenation and hemodynamics during rapid heat stress","volume":"1798","author":"Coehoorn","year":"2023","journal-title":"Brain Res."},{"key":"10.1016\/j.apergo.2026.104902_bib10","doi-asserted-by":"crossref","DOI":"10.1016\/j.firesaf.2020.103240","article-title":"Firefighter neural function and decision-making following rapid heat stress","volume":"118","author":"Coehoorn","year":"2020","journal-title":"Fire Saf. J."},{"issue":"1","key":"10.1016\/j.apergo.2026.104902_bib14","doi-asserted-by":"crossref","first-page":"i","DOI":"10.1097\/00005768-199610000-00045","article-title":"American college of sports medicine position stand. Exercise and fluid replacement","volume":"28","author":"Convertino","year":"1996","journal-title":"Med. Sci. Sports Exerc."},{"issue":"8","key":"10.1016\/j.apergo.2026.104902_bib15","doi-asserted-by":"crossref","first-page":"719","DOI":"10.3109\/07420528.2011.597530","article-title":"The validity of temperature-sensitive ingestible capsules for measuring core body temperature in laboratory protocols","volume":"28","author":"Darwent","year":"2011","journal-title":"Chronobiol. Int."},{"issue":"2","key":"10.1016\/j.apergo.2026.104902_bib16","doi-asserted-by":"crossref","first-page":"91","DOI":"10.12968\/bjon.2014.23.2.91","article-title":"Determining fever in children: the search for an ideal thermometer","volume":"23","author":"El-Radhi","year":"2014","journal-title":"Br. J. Nurs."},{"key":"10.1016\/j.apergo.2026.104902_bib17","series-title":"US Fire Department Profile 2020","author":"Fahy","year":"2022"},{"issue":"11","key":"10.1016\/j.apergo.2026.104902_bib18","first-page":"2133","article-title":"Management of heatstroke and heat exhaustion","volume":"71","author":"Glazer","year":"2005","journal-title":"Am. Fam. Physician"},{"issue":"4","key":"10.1016\/j.apergo.2026.104902_bib19","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1017\/S0022172400006811","article-title":"The influence of high air temperatures no. I","volume":"5","author":"Haldane","year":"1905","journal-title":"Epidemiol. Infect."},{"issue":"8","key":"10.1016\/j.apergo.2026.104902_bib20","first-page":"778","article-title":"Task categorization and the limits of human performance in extreme heat","volume":"53","author":"Hancock","year":"1982","journal-title":"Aviat. Space Environ. Med."},{"issue":"8","key":"10.1016\/j.apergo.2026.104902_bib21","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.1080\/001401398186469","article-title":"Human occupational and performance limits under stress: the thermal environment as a prototypical example","volume":"41","author":"Hancock","year":"1998","journal-title":"Ergonomics"},{"key":"10.1016\/j.apergo.2026.104902_bib22","first-page":"7983","article-title":"Temporal analysis of skin and core temperature dynamics in firefighters under uncompensable heat stress","volume":"23","author":"Hisatomi","year":"2025","journal-title":"Ann. Fam. Med."},{"key":"10.1016\/j.apergo.2026.104902_bib23","first-page":"1","article-title":"Validity of a noninvasive estimation of deep body temperature when wearing personal protective equipment during exercise and recovery","volume":"6","author":"Hunt","year":"2019","journal-title":"Milit. Med. Res."},{"issue":"7","key":"10.1016\/j.apergo.2026.104902_bib24","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1542\/pir.28.7.249","article-title":"Heat illness and heat stroke","volume":"28","author":"Jardine","year":"2007","journal-title":"Pediatr. Rev."},{"issue":"3","key":"10.1016\/j.apergo.2026.104902_bib26","doi-asserted-by":"crossref","first-page":"370","DOI":"10.2486\/indhealth.2018-0063","article-title":"Frequency of firefighters' heat-related illness and its association with removing personal protective equipment and working hours","volume":"57","author":"Kim","year":"2019","journal-title":"Ind. Health"},{"issue":"4","key":"10.1016\/j.apergo.2026.104902_bib25","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1080\/00140139.2015.1075604","article-title":"Skin sites to predict deep-body temperature while wearing firefighters' personal protective equipment during periodical changes in air temperature","volume":"59","author":"Kim","year":"2016","journal-title":"Ergonomics"},{"issue":"4","key":"10.1016\/j.apergo.2026.104902_bib27","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1007\/s00421-005-0086-4","article-title":"Maximal lactate steady state determination with a single incremental test exercise","volume":"96","author":"Laplaud","year":"2006","journal-title":"Eur. J. Appl. Physiol."},{"issue":"2","key":"10.1016\/j.apergo.2026.104902_bib28","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1080\/15459624.2012.747404","article-title":"Validity and reliability of multiparameter physiological measurements recorded by the equivital LifeMonitor during activities of various intensities","volume":"10","author":"Liu","year":"2013","journal-title":"J. Occup. Environ. Hyg."},{"issue":"5","key":"10.1016\/j.apergo.2026.104902_bib29","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.1016\/0360-3016(91)90297-H","article-title":"Evaluation of an ingestible telemetric temperature sensor for deep hyperthermia applications","volume":"21","author":"Mittal","year":"1991","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"issue":"1","key":"10.1016\/j.apergo.2026.104902_bib30","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1152\/jappl.1994.77.1.216","article-title":"Physiological tolerance to uncompensable heat stress: effects of exercise intensity, protective clothing, and climate","volume":"77","author":"Montain","year":"1994","journal-title":"J. Appl. Physiol."},{"key":"10.1016\/j.apergo.2026.104902_bib31","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1007\/s10015-020-00632-4","article-title":"Human body skin temperature prediction based on machine learning","volume":"26","author":"Morishima","year":"2021","journal-title":"Artif. Life Robot."},{"key":"10.1016\/j.apergo.2026.104902_bib32","doi-asserted-by":"crossref","first-page":"922","DOI":"10.3389\/fphys.2017.00922","article-title":"Respiratory frequency during exercise: the neglected physiological measure","volume":"8","author":"Nicol\u00f2","year":"2017","journal-title":"Front. Physiol."},{"issue":"1","key":"10.1016\/j.apergo.2026.104902_bib33","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.shaw.2021.11.003","article-title":"Comparisons of core temperature between a telemetric pill and heart rate estimated core temperature in firefighters","volume":"13","author":"Pearson","year":"2022","journal-title":"Saf. Health Work"},{"key":"10.1016\/j.apergo.2026.104902_bib34","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.compbiomed.2019.02.004","article-title":"Heat strain decision aid (HSDA) accurately predicts individual-based core body temperature rise while wearing chemical protective clothing","volume":"107","author":"Potter","year":"2019","journal-title":"Comput. Biol. Med."},{"issue":"1","key":"10.1016\/j.apergo.2026.104902_bib35","doi-asserted-by":"crossref","first-page":"136","DOI":"10.3109\/10903127.2011.614047","article-title":"Estimating core temperature with external devices after exertional heat stress in thermal protective clothing","volume":"16","author":"Pryor","year":"2012","journal-title":"Prehosp. Emerg. Care"},{"issue":"9","key":"10.1016\/j.apergo.2026.104902_bib37","doi-asserted-by":"crossref","first-page":"1168","DOI":"10.1093\/annhyg\/mev054","article-title":"Prediction of core body temperature from multiple variables","volume":"59","author":"Richmond","year":"2015","journal-title":"Ann. Occup. Hyg."},{"issue":"11","key":"10.1016\/j.apergo.2026.104902_bib36","doi-asserted-by":"crossref","first-page":"1531","DOI":"10.1088\/0967-3334\/34\/11\/1531","article-title":"Insulated skin temperature as a measure of core body temperature for individuals wearing CBRN protective clothing","volume":"34","author":"Richmond","year":"2013","journal-title":"Physiol. Meas."},{"key":"10.1016\/j.apergo.2026.104902_bib38","doi-asserted-by":"crossref","DOI":"10.1016\/j.apergo.2019.103001","article-title":"Monitoring core temperature of firefighters to validate a wearable non-invasive core thermometer in different types of protective clothing: concurrent in-vivo validation","volume":"83","author":"Roossien","year":"2020","journal-title":"Appl. Ergon."},{"issue":"2","key":"10.1016\/j.apergo.2026.104902_bib39","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1088\/0967-3334\/36\/2\/259","article-title":"Intestinal temperature does not reflect rectal temperature during prolonged, intense running with cold fluid ingestion","volume":"36","author":"Savoie","year":"2015","journal-title":"Physiol. Meas."},{"issue":"5","key":"10.1016\/j.apergo.2026.104902_bib40","doi-asserted-by":"crossref","first-page":"2055","DOI":"10.1152\/jappl.2001.91.5.2055","article-title":"Influence of aerobic fitness and body fatness on tolerance to uncompensable heat stress","volume":"91","author":"Selkirk","year":"2001","journal-title":"J. Appl. Physiol."},{"key":"10.1016\/j.apergo.2026.104902_bib41","doi-asserted-by":"crossref","DOI":"10.1016\/j.jtherbio.2023.103486","article-title":"An assessment of the validity and reliability of the P022-P version of e-Celsius core temperature capsules","volume":"112","author":"Service","year":"2023","journal-title":"J. Therm. Biol."},{"issue":"3","key":"10.1016\/j.apergo.2026.104902_bib42","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1249\/MSS.0b013e31815cc43e","article-title":"The effect of cool water ingestion on gastrointestinal pill temperature","volume":"40","author":"Wilkinson","year":"2008","journal-title":"Med. Sci. Sports Exerc."}],"container-title":["Applied Ergonomics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003687026001808?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003687026001808?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T12:05:32Z","timestamp":1791288332000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0003687026001808"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2027,4]]},"references-count":42,"alternative-id":["S0003687026001808"],"URL":"https:\/\/doi.org\/10.1016\/j.apergo.2026.104902","relation":{},"ISSN":["0003-6870"],"issn-type":[{"value":"0003-6870","type":"print"}],"subject":[],"published":{"date-parts":[[2027,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A supervised machine learning approach to predict core temperature for workers with high-level personal protective equipment","name":"articletitle","label":"Article Title"},{"value":"Applied Ergonomics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.apergo.2026.104902","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"104902"}}