{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T22:38:54Z","timestamp":1791239934799,"version":"4.1.0"},"reference-count":38,"publisher":"Elsevier BV","issue":"6","content-domain":{"domain":["archives-pmr.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Archives of Physical Medicine and Rehabilitation"],"published-print":{"date-parts":[[2014,6]]},"DOI":"10.1016\/j.apmr.2014.01.028","type":"journal-article","created":{"date-parts":[[2014,2,20]],"date-time":"2014-02-20T01:15:34Z","timestamp":1392858934000},"page":"1201-1211.e1","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":127,"title":["Implanted Neuroprosthesis for Restoring Arm and Hand Function in People With High Level Tetraplegia"],"prefix":"10.1016","volume":"95","author":[{"given":"William D.","family":"Memberg","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katharine H.","family":"Polasek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronald L.","family":"Hart","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anne M.","family":"Bryden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin L.","family":"Kilgore","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory A.","family":"Nemunaitis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Harry A.","family":"Hoyen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael W.","family":"Keith","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert F.","family":"Kirsch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.apmr.2014.01.028_bib1","first-page":"415","article-title":"Upper limb functions regained in quadriplegia: a hybrid computerized neuromuscular stimulation system","volume":"71","author":"Nathan","year":"1990","journal-title":"Arch Phys Med Rehabil"},{"key":"10.1016\/j.apmr.2014.01.028_bib2","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1080\/10790268.2001.11753565","article-title":"A neuroprosthesis for high tetraplegia","volume":"24","author":"Yu","year":"2001","journal-title":"J Spinal Cord Med"},{"key":"10.1016\/j.apmr.2014.01.028_bib3","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1310\/G9T5-CCK9-Y0WT-4714","article-title":"An implanted neuroprosthesis for high tetraplegia","volume":"10","author":"Bryden","year":"2005","journal-title":"Top Spinal Cord Inj Rehabil"},{"key":"10.1016\/j.apmr.2014.01.028_bib4","doi-asserted-by":"crossref","first-page":"1380","DOI":"10.1053\/apmr.2001.25910","article-title":"Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia: a multicenter study","volume":"82","author":"Peckham","year":"2001","journal-title":"Arch Phys Med Rehabil"},{"key":"10.1016\/j.apmr.2014.01.028_bib5","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1682\/JRRD.2003.11.0477","article-title":"Restoration of elbow extension via functional electrical stimulation in individuals with tetraplegia","volume":"40","author":"Memberg","year":"2003","journal-title":"J Rehabil Res Dev"},{"key":"10.1016\/j.apmr.2014.01.028_bib6","first-page":"609","article-title":"Preliminary performance of a surgically implanted neuroprosthesis for standing and transfer\u2013where do we stand?","volume":"38","author":"Davis","year":"2001","journal-title":"J Rehabil Res Dev"},{"key":"10.1016\/j.apmr.2014.01.028_bib7","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1109\/86.808942","article-title":"Implanted functional electrical stimulation system for mobility in paraplegia: a follow-up case report","volume":"7","author":"Kobetic","year":"1999","journal-title":"IEEE Trans Rehabil Eng"},{"key":"10.1016\/j.apmr.2014.01.028_bib8","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1310\/BCVF-HBW7-MYWV-54MG","article-title":"Restoration of bladder, bowel, and sexual function","volume":"5","author":"Creasey","year":"1999","journal-title":"Top Spinal Cord Inj Rehabil"},{"key":"10.1016\/j.apmr.2014.01.028_bib9","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1146\/annurev.bioeng.6.040803.140103","article-title":"Functional electrical stimulation for neuromuscular applications","volume":"7","author":"Peckham","year":"2005","journal-title":"Annu Rev Biomed Eng"},{"key":"10.1016\/j.apmr.2014.01.028_bib10","doi-asserted-by":"crossref","first-page":"754","DOI":"10.1109\/10.32108","article-title":"A multichannel FES system for the restoration of motor functions in high spinal cord injury patients: a respiration-controlled system for multijoint upper extremity","volume":"36","author":"Hoshimiya","year":"1989","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.apmr.2014.01.028_bib11","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1620\/tjem.187.329","article-title":"Restoration of shoulder movement in quadriplegic and hemiplegic patients by functional electrical stimulation using percutaneous multiple electrodes","volume":"187","author":"Kameyama","year":"1999","journal-title":"Tohoku J Exp Med"},{"key":"10.1016\/j.apmr.2014.01.028_bib12","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1007\/BF02441635","article-title":"An FNS-based system for generating upper limb function in the C4 quadriplegic","volume":"27","author":"Nathan","year":"1989","journal-title":"Med Biol Eng Comput"},{"key":"10.1016\/j.apmr.2014.01.028_bib13","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1109\/86.547926","article-title":"Development of an upper extremity FES system for individuals with C4 tetraplegia","volume":"4","author":"Smith","year":"1996","journal-title":"IEEE Trans Rehabil Eng"},{"key":"10.1016\/j.apmr.2014.01.028_bib14","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1080\/01952307.1992.11761522","article-title":"Bipolar latissimus dorsi transposition and functional neuromuscular stimulation to restore elbow flexion in an individual with C4 quadriplegia and C5 denervation","volume":"15","author":"Betz","year":"1992","journal-title":"J Am Paraplegia Soc"},{"key":"10.1016\/j.apmr.2014.01.028_bib15","doi-asserted-by":"crossref","first-page":"1714","DOI":"10.1016\/j.jbiomech.2008.03.001","article-title":"A musculoskeletal model of the upper extremity for use in the development of neuroprosthetic systems","volume":"41","author":"Blana","year":"2008","journal-title":"J Biomech"},{"key":"10.1016\/j.apmr.2014.01.028_bib16","doi-asserted-by":"crossref","first-page":"941","DOI":"10.1109\/TBME.2008.2005946","article-title":"A real-time, 3-D musculoskeletal model for dynamic simulation of arm movements","volume":"56","author":"Chadwick","year":"2009","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.apmr.2014.01.028_bib17","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1682\/JRRD.2012.02.0034","article-title":"Selection of muscle and nerve-cuff electrodes for neuroprostheses using customizable musculoskeletal model","volume":"50","author":"Blana","year":"2013","journal-title":"J Rehabil Res Dev"},{"key":"10.1016\/j.apmr.2014.01.028_bib18","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1109\/TNSRE.2010.2079952","article-title":"Design and testing of an advanced implantable neuroprosthesis with myoelectric control","volume":"19","author":"Hart","year":"2011","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"10.1016\/j.apmr.2014.01.028_bib19","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1016\/j.jhsa.2008.01.007","article-title":"An implanted upper-extremity neuroprosthesis using myoelectric control","volume":"33","author":"Kilgore","year":"2008","journal-title":"J Hand Surg [Am]"},{"key":"10.1016\/j.apmr.2014.01.028_bib20","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1109\/86.593301","article-title":"Tissue response to chronically stimulated implanted epimysial and intramuscular electrodes","volume":"5","author":"Akers","year":"1997","journal-title":"IEEE Trans Rehabil Eng"},{"key":"10.1016\/j.apmr.2014.01.028_bib21","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1109\/86.313149","article-title":"A surgically-implanted intramuscular electrode for an implantable neuromuscular stimulation system","volume":"2","author":"Memberg","year":"1994","journal-title":"IEEE Trans Rehabil Eng"},{"key":"10.1016\/j.apmr.2014.01.028_bib22","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1682\/JRRD.2003.11.0457","article-title":"Durability of implanted electrodes and leads in an upper-limb neuroprosthesis","volume":"40","author":"Kilgore","year":"2003","journal-title":"J Rehabil Res Dev"},{"key":"10.1016\/j.apmr.2014.01.028_bib23","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1109\/10.8670","article-title":"A spiral nerve cuff electrode for peripheral nerve stimulation","volume":"35","author":"Naples","year":"1988","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.apmr.2014.01.028_bib24","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1109\/86.736150","article-title":"Stability of the input-output properties of chronically implanted multiple contact nerve cuff stimulating electrodes","volume":"6","author":"Grill","year":"1998","journal-title":"IEEE Trans Rehabil Eng"},{"key":"10.1016\/j.apmr.2014.01.028_bib25","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1109\/TNSRE.2009.2032603","article-title":"Stimulation stability and selectivity of chronically implanted multicontact nerve cuff electrodes in the human upper extremity","volume":"17","author":"Polasek","year":"2009","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"10.1016\/j.apmr.2014.01.028_bib26","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1109\/TNSRE.2007.891383","article-title":"Human nerve stimulation thresholds and selectivity using a multi-contact nerve cuff electrode","volume":"15","author":"Polasek","year":"2007","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"10.1016\/j.apmr.2014.01.028_bib27","doi-asserted-by":"crossref","unstructured":"Memberg WD, Stage TG, Kirsch RF. A fully implanted intramuscular bipolar myoelectric signal recording electrode. Neuromodulation 2014. [Epub ahead of print].","DOI":"10.1111\/ner.12165"},{"key":"10.1016\/j.apmr.2014.01.028_bib28","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1109\/TNSRE.2008.2006216","article-title":"Evaluation of head orientation and neck muscle EMG signals as command inputs to a human-computer interface for individuals with high tetraplegia","volume":"16","author":"Williams","year":"2008","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"10.1016\/j.apmr.2014.01.028_bib29","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1109\/TNSRE.2008.2003390","article-title":"Standing after spinal cord injury with four-contact nerve-cuff electrodes for quadriceps stimulation","volume":"16","author":"Fisher","year":"2008","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"10.1016\/j.apmr.2014.01.028_bib30","series-title":"Clinical implementation of nerve cuff electrodes for an upper extremity neuroprosthesis [dissertation]","author":"Polasek","year":"2007"},{"key":"10.1016\/j.apmr.2014.01.028_bib31","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1016\/S0268-0033(01)00071-7","article-title":"A transducer to measure isometric elbow moments","volume":"16","author":"Memberg","year":"2001","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"10.1016\/j.apmr.2014.01.028_bib32","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1007\/BF02441809","article-title":"Grasp synthesis for upper-extremity FNS. Part 1. Automated method for synthesising the stimulus map","volume":"31","author":"Kilgore","year":"1993","journal-title":"Med Biol Eng Comput"},{"key":"10.1016\/j.apmr.2014.01.028_bib33","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/0363-5023(94)90008-6","article-title":"Development of a quantitative hand grasp and release test for patients with tetraplegia using a hand neuroprosthesis","volume":"19","author":"Wuolle","year":"1994","journal-title":"J Hand Surg [Am]"},{"key":"10.1016\/j.apmr.2014.01.028_bib34","series-title":"Occupational therapy for physical dysfunction","first-page":"184","article-title":"Evaluation","author":"Trombly","year":"1989"},{"key":"10.1016\/j.apmr.2014.01.028_bib35","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1080\/10790268.2008.11760741","article-title":"Mobile arm supports: evidence-based benefits and criteria for use","volume":"31","author":"Atkins","year":"2008","journal-title":"J Spinal Cord Med"},{"key":"10.1016\/j.apmr.2014.01.028_bib36","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1310\/FCDG-QHTV-M9KL-5478","article-title":"Mobile arm supports: history, application, and work in progress","volume":"11","author":"Landsberger","year":"2005","journal-title":"Top Spinal Cord Inj Rehabil"},{"key":"10.1016\/j.apmr.2014.01.028_bib37","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1310\/sci1304-37","article-title":"Assessing activity of daily living performance after implantation of an upper extremity neuroprosthesis","volume":"13","author":"Bryden","year":"2008","journal-title":"Top Spinal Cord Inj Rehabil"},{"key":"10.1016\/j.apmr.2014.01.028_bib38","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/S0003-9993(99)90123-5","article-title":"Satisfaction with and usage of a hand neuroprosthesis","volume":"80","author":"Wuolle","year":"1999","journal-title":"Arch Phys Med Rehabil"}],"container-title":["Archives of Physical Medicine and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003999314001221?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003999314001221?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,10,6]],"date-time":"2018-10-06T13:51:30Z","timestamp":1538833890000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0003999314001221"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,6]]},"references-count":38,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2014,6]]}},"alternative-id":["S0003999314001221"],"URL":"https:\/\/doi.org\/10.1016\/j.apmr.2014.01.028","relation":{},"ISSN":["0003-9993"],"issn-type":[{"value":"0003-9993","type":"print"}],"subject":[],"published":{"date-parts":[[2014,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Implanted Neuroprosthesis for Restoring Arm and Hand Function in People With High Level Tetraplegia","name":"articletitle","label":"Article Title"},{"value":"Archives of Physical Medicine and Rehabilitation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.apmr.2014.01.028","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"simple-article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}