{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T16:35:59Z","timestamp":1786984559586,"version":"build-2736575974"},"reference-count":50,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2017,6,1]],"date-time":"2017-06-01T00:00:00Z","timestamp":1496275200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","archives-pmr.org","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Archives of Physical Medicine and Rehabilitation"],"published-print":{"date-parts":[[2017,6]]},"DOI":"10.1016\/j.apmr.2016.12.001","type":"journal-article","created":{"date-parts":[[2017,1,3]],"date-time":"2017-01-03T20:30:54Z","timestamp":1483475454000},"page":"1187-1194","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":10,"title":["Microcirculatory Assessment of Arterial Below-Knee Stumps: Near-Infrared Spectroscopy Versus Transcutaneous Oxygen Tension\u2014A Preliminary Study in Prosthesis Users"],"prefix":"10.1016","volume":"98","author":[{"given":"Davy","family":"Laroche","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9-Luis","family":"Barnay","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bastien","family":"Tourlonias","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cyril","family":"Orta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christine","family":"Obert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Marie","family":"Casillas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.apmr.2016.12.001_bib1","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1001\/archsurg.139.4.395","article-title":"Major lower extremity amputation","volume":"139","author":"Aulivola","year":"2004","journal-title":"Arch Surg"},{"key":"10.1016\/j.apmr.2016.12.001_bib2","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1177\/0309364611430885","article-title":"Predicting prosthetic use in elderly patients after major lower limb amputation","volume":"36","author":"van Eijk","year":"2012","journal-title":"Prosthet Orthot Int"},{"key":"10.1016\/j.apmr.2016.12.001_bib3","doi-asserted-by":"crossref","first-page":"1323","DOI":"10.1016\/j.jvs.2013.11.076","article-title":"Impact of amputation level and comorbidities on functional status of nursing home residents after lower extremity amputation","volume":"59","author":"Vogel","year":"2014","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.apmr.2016.12.001_bib4","doi-asserted-by":"crossref","first-page":"42","DOI":"10.2106\/00004623-197658010-00007","article-title":"Energy cost of walking of amputees: the influence of level of amputation","volume":"58","author":"Waters","year":"1976","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.apmr.2016.12.001_bib5","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1016\/j.ahj.2012.12.002","article-title":"High mortality risks after major lower extremity amputation in Medicare patients with peripheral artery disease","volume":"165","author":"Jones","year":"2013","journal-title":"Am Heart J"},{"key":"10.1016\/j.apmr.2016.12.001_bib6","doi-asserted-by":"crossref","first-page":"1474","DOI":"10.1016\/j.apmr.2015.03.024","article-title":"Health-related profiles of people with lower limb loss","volume":"96","author":"Amtmann","year":"2015","journal-title":"Arch Phys Med Rehabil"},{"key":"10.1016\/j.apmr.2016.12.001_bib7","doi-asserted-by":"crossref","first-page":"1374","DOI":"10.1016\/j.jvs.2011.04.048","article-title":"Predictors of wound complications following major amputation for critical limb ischemia","volume":"54","author":"Hasanadka","year":"2011","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.apmr.2016.12.001_bib8","doi-asserted-by":"crossref","first-page":"1514","DOI":"10.2106\/00004623-198870100-00011","article-title":"Results of amputation for gangrene in diabetic and non-diabetic patients. Selection of amputation level using photoelectric measurements of skin-perfusion pressure","volume":"70","author":"Christensen","year":"1988","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.apmr.2016.12.001_bib9","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1097\/00002060-198808000-00003","article-title":"Occlusive vascular disease of lower limbs: diagnosis, amputation surgery and rehabilitation","volume":"67","author":"Stern","year":"1988","journal-title":"Am J Phys Med Rehabil"},{"key":"10.1016\/j.apmr.2016.12.001_bib10","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1016\/j.apmr.2004.09.003","article-title":"Dermatologic conditions associated with use of a lower-extremity prosthesis","volume":"86","author":"Dudek","year":"2005","journal-title":"Arch Phys Med Rehabil"},{"key":"10.1016\/j.apmr.2016.12.001_bib11","doi-asserted-by":"crossref","first-page":"363","DOI":"10.2106\/00004623-198365030-00011","article-title":"Doppler-determined segmental pressures and wound-healing in amputations for vascular disease","volume":"65","author":"Cederberg","year":"1983","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.apmr.2016.12.001_bib12","first-page":"75","article-title":"The clinical value of preoperative indirect systolic ankle pressure measurements in wound healing after amputation of the lower extremity","volume":"37","author":"van Soest","year":"1985","journal-title":"Neth J Surg"},{"key":"10.1016\/j.apmr.2016.12.001_bib13","first-page":"232","article-title":"The association between lowest palpable pulse and wound healing in below knee amputations","volume":"67","author":"O'Dwyer","year":"1985","journal-title":"Ann R Coll Surg Engl"},{"key":"10.1016\/j.apmr.2016.12.001_bib14","doi-asserted-by":"crossref","first-page":"378","DOI":"10.2106\/00004623-198264030-00007","article-title":"Segmental transcutaneous measurements of PO2 in patients requiring below-the-knee amputation for peripheral vascular insufficiency","volume":"64","author":"Burgess","year":"1982","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.apmr.2016.12.001_bib15","first-page":"31","article-title":"Predicting stump healing following amputation for peripheral vascular disease using the transcutaneous oxygen monitor","volume":"69","author":"Dowd","year":"1987","journal-title":"Ann R Coll Surg Engl"},{"key":"10.1016\/j.apmr.2016.12.001_bib16","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1007\/BF00586844","article-title":"Quantitative continuous measurement of partial oxygen pressure on the skin of adults and new-born babies","volume":"337","author":"Huch","year":"1972","journal-title":"Pflugers Arch"},{"key":"10.1016\/j.apmr.2016.12.001_bib17","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/0022-4804(89)90183-2","article-title":"A statistical assessment of the dependability of transcutaneous tissue oxygen tension measurements","volume":"46","author":"Stein","year":"1989","journal-title":"J Surg Res"},{"key":"10.1016\/j.apmr.2016.12.001_bib18","first-page":"36","article-title":"The use of transcutaneous oximetry in the noninvasive vascular laboratory","volume":"11","author":"Rooke","year":"1992","journal-title":"Int Angiol"},{"key":"10.1016\/j.apmr.2016.12.001_bib19","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1097\/PHM.0b013e3182876a06","article-title":"Noninvasive arterial studies including transcutaneous oxygen pressure measurements with the limbs elevated or dependent to predict healing after partial foot amputation","volume":"92","author":"Andrews","year":"2013","journal-title":"Am J Phys Med Rehabil"},{"key":"10.1016\/j.apmr.2016.12.001_bib20","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1016\/S0950-821X(89)80072-6","article-title":"Reproducibility of skin blood flow, perfusion pressure and oxygen tension measurements in advanced lower limb ischaemia","volume":"3","author":"Lukkari-Rautiarinen","year":"1989","journal-title":"Eur J Vasc Surg"},{"key":"10.1016\/j.apmr.2016.12.001_bib21","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1067\/mva.2001.108011","article-title":"Interobserver and intraobserver reproducibility of peripheral blood and oxygen pressure measurements in the assessment of lower extremity arterial disease","volume":"33","author":"de Graaff","year":"2001","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.apmr.2016.12.001_bib22","first-page":"71","article-title":"TcPO2 and viability of an amputation stump. Preliminary study","volume":"10","author":"Casillas","year":"1985","journal-title":"J Mal Vasc"},{"key":"10.1016\/j.apmr.2016.12.001_bib23","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1097\/00002060-199302000-00007","article-title":"Transcutaneous oxygen pressure. An effective measure for prosthesis fitting on below-knee amputations","volume":"72","author":"Casillas","year":"1993","journal-title":"Am J Phys Med Rehabil"},{"key":"10.1016\/j.apmr.2016.12.001_bib24","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1097\/00002060-199505000-00003","article-title":"Postoperative transcutaneous oxygen measurement in the prediction of delayed wound healing and prosthetic fitting among amputees during rehabilitation. A pilot study","volume":"74","author":"Yablon","year":"1995","journal-title":"Am J Phys Med Rehabil"},{"key":"10.1016\/j.apmr.2016.12.001_bib25","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1097\/00008526-198810000-00005","article-title":"Application of the transcutaneous oxygen monitor to amputees undergoing early fitting of below-knee patellar tendon bearing prostheses","volume":"1","author":"Linge","year":"1988","journal-title":"J Prosthet Orthot"},{"key":"10.1016\/j.apmr.2016.12.001_bib26","doi-asserted-by":"crossref","first-page":"558","DOI":"10.1016\/0741-5214(92)90196-F","article-title":"Predictive value of transcutaneous oxygen pressure and amputation success by use of supine and elevation measurements","volume":"15","author":"Bacharach","year":"1992","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.apmr.2016.12.001_bib27","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1016\/j.pmrj.2010.06.011","article-title":"The use of elevation and dependency to enhance the predictive value of transcutaneous oxygen pressure measurements in the assessment of foot amputation healing","volume":"2","author":"Andrews","year":"2010","journal-title":"PM R"},{"key":"10.1016\/j.apmr.2016.12.001_bib28","doi-asserted-by":"crossref","first-page":"202","DOI":"10.12968\/jowc.2010.19.5.48048","article-title":"Transcutaneous oxygen tension: a useful predictor of ulcer healing in critical limb ischaemia","volume":"19","author":"Ruangsetakit","year":"2010","journal-title":"J Wound Care"},{"key":"10.1016\/j.apmr.2016.12.001_bib29","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.vascn.2005.09.004","article-title":"Non-invasive methods and stimuli for evaluating the skin\u2216textquotesingles microcirculation","volume":"54","author":"Wright","year":"2006","journal-title":"J Pharmacol Toxicol Methods"},{"key":"10.1016\/j.apmr.2016.12.001_bib30","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1016\/j.ymeth.2008.04.005","article-title":"Non-invasive NIR spectroscopy of human brain function during exercise","volume":"45","author":"Perrey","year":"2008","journal-title":"Methods"},{"key":"10.1016\/j.apmr.2016.12.001_bib31","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1007\/978-1-4614-7411-1_21","article-title":"Muscle, prefrontal, and motor cortex oxygenation profiles during prolonged fatiguing exercise","volume":"789","author":"Rupp","year":"2013","journal-title":"Adv Exp Med Biol"},{"key":"10.1016\/j.apmr.2016.12.001_bib32","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1177\/0309364612437904","article-title":"Selecting a test for the clinical assessment of balance and walking capacity at the definitive fitting state after unilateral amputation: a comparative study","volume":"36","author":"Gremeaux","year":"2012","journal-title":"Prosthet Orthot Int"},{"key":"10.1016\/j.apmr.2016.12.001_bib33","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1186\/1743-0003-11-86","article-title":"Reliability, validity, and effectiveness of center of pressure parameters in assessing stabilometric platform in subjects with incomplete spinal cord injury: a serial cross-sectional study","volume":"11","author":"Tamburella","year":"2014","journal-title":"J Neuroeng Rehabil"},{"key":"10.1016\/j.apmr.2016.12.001_bib34","doi-asserted-by":"crossref","first-page":"1357","DOI":"10.1016\/j.joca.2015.03.029","article-title":"Test\u2013retest reliability and responsiveness of centre of pressure measurements in patients with hip osteoarthritis","volume":"23","author":"Laroche","year":"2015","journal-title":"Osteoarthritis Cartilage"},{"key":"10.1016\/j.apmr.2016.12.001_bib35","first-page":"231","article-title":"Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM","volume":"19","author":"Weir","year":"2005","journal-title":"J Strength Cond Res"},{"key":"10.1016\/j.apmr.2016.12.001_bib36","doi-asserted-by":"crossref","first-page":"634","DOI":"10.1016\/j.jelekin.2013.01.008","article-title":"Age-related differences in time-limit performance and force platform-based balance measures during one-leg stance","volume":"23","author":"da Silva","year":"2013","journal-title":"J Electromyogr Kinesiol"},{"key":"10.1016\/j.apmr.2016.12.001_bib37","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1016\/j.gaitpost.2014.03.016","article-title":"Test re-test reliability of centre of pressure measures during standing balance in individuals with knee osteoarthritis","volume":"40","author":"Takacs","year":"2014","journal-title":"Gait Posture"},{"key":"10.1016\/j.apmr.2016.12.001_bib38","series-title":"Statistical power analysis for the behavioral sciences","author":"Cohen","year":"1988"},{"key":"10.1016\/j.apmr.2016.12.001_bib39","series-title":"Correlations","author":"Munro","year":"1993"},{"key":"10.1016\/j.apmr.2016.12.001_bib40","first-page":"251","article-title":"The modern concept of the general management of amputee rehabilitation including immediate post-operative fitting","volume":"40","author":"Vitali","year":"1967","journal-title":"Ann R Coll Surg Engl"},{"key":"10.1016\/j.apmr.2016.12.001_bib41","doi-asserted-by":"crossref","first-page":"724","DOI":"10.2106\/00004623-197961050-00013","article-title":"An innovative removable rigid dressing technique for below-the-knee amputation","volume":"61","author":"Wu","year":"1979","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.apmr.2016.12.001_bib42","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1080\/17461550500066832","article-title":"Stump management after trans-tibial amputation: a systematic review","volume":"29","author":"Nawijn","year":"2005","journal-title":"Prosthet Orthot Int"},{"key":"10.1016\/j.apmr.2016.12.001_bib43","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1080\/17461550500069588","article-title":"Early treatment of trans-tibial amputees: retrospective analysis of early fitting and elastic bandaging","volume":"29","author":"Velzen","year":"2005","journal-title":"Prosthet Orthot Int"},{"key":"10.1016\/j.apmr.2016.12.001_bib44","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1016\/S0003-9993(99)90038-2","article-title":"Healing of open stump wounds after vascular below-knee amputation: plaster cast socket with silicone sleeve versus elastic compression","volume":"80","author":"Vigier","year":"1999","journal-title":"Arch Phys Med Rehabil"},{"key":"10.1016\/j.apmr.2016.12.001_bib45","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.ejvs.2007.07.015","article-title":"Near-infrared spectroscopy for evaluation of peripheral vascular disease. A systematic review of literature","volume":"35","author":"Vardi","year":"2008","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1016\/j.apmr.2016.12.001_bib46","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/j.ejvs.2009.06.011","article-title":"A dynamic objective evaluation of peripheral arterial disease by near-infrared spectroscopy","volume":"38","author":"Manfredini","year":"2009","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1016\/j.apmr.2016.12.001_bib47","doi-asserted-by":"crossref","first-page":"e9","DOI":"10.1016\/j.annfar.2013.11.014","article-title":"Lower limb peripheral NIRS parameters during a vascular occlusion test: an experimental study in healthy volunteers","volume":"33","author":"Fellahi","year":"2014","journal-title":"Ann Fr Anesth Reanim"},{"key":"10.1016\/j.apmr.2016.12.001_bib48","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1006\/jsre.1997.5164","article-title":"Near infrared spectroscopy for noninvasive assessment of claudication","volume":"72","author":"Kooijman","year":"1997","journal-title":"J Surg Res"},{"key":"10.1016\/j.apmr.2016.12.001_bib49","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1007\/978-1-4615-0075-9_66","article-title":"Postocclusive reactive hyperemia in healthy volunteers and patients with peripheral vascular disease measured by three noninvasive methods","volume":"530","author":"Jarm","year":"2003","journal-title":"Adv Exp Med Biol"},{"key":"10.1016\/j.apmr.2016.12.001_bib50","doi-asserted-by":"crossref","first-page":"994","DOI":"10.1016\/j.jvs.2005.03.020","article-title":"Near-infrared spectroscopy and transcutaneous oxygen pressure during exercise to detect arterial ischemia at the buttock level: comparison with arteriography","volume":"41","author":"Bouy\u00e9","year":"2005","journal-title":"J Vasc Surg"}],"container-title":["Archives of Physical Medicine and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003999316313661?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003999316313661?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,5]],"date-time":"2018-09-05T06:58:59Z","timestamp":1536130739000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0003999316313661"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6]]},"references-count":50,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2017,6]]}},"alternative-id":["S0003999316313661"],"URL":"https:\/\/doi.org\/10.1016\/j.apmr.2016.12.001","relation":{},"ISSN":["0003-9993"],"issn-type":[{"value":"0003-9993","type":"print"}],"subject":[],"published":{"date-parts":[[2017,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Microcirculatory Assessment of Arterial Below-Knee Stumps: Near-Infrared Spectroscopy Versus Transcutaneous Oxygen Tension\u2014A Preliminary Study in Prosthesis Users","name":"articletitle","label":"Article Title"},{"value":"Archives of Physical Medicine and Rehabilitation","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.apmr.2016.12.001","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 by the American Congress of Rehabilitation Medicine","name":"copyright","label":"Copyright"}]}}