{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T22:57:57Z","timestamp":1768345077520,"version":"3.49.0"},"reference-count":19,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2016,8,1]],"date-time":"2016-08-01T00:00:00Z","timestamp":1470009600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/501100005085","name":"Beijing Institute of Technology","doi-asserted-by":"publisher","award":["20130242017"],"award-info":[{"award-number":["20130242017"]}],"id":[{"id":"10.13039\/501100005085","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100011349","name":"State Key Laboratory of Explosion Science and Technology","doi-asserted-by":"crossref","award":["YBKT16-09"],"award-info":[{"award-number":["YBKT16-09"]}],"id":[{"id":"10.13039\/501100011349","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100011349","name":"State Key Laboratory of Explosion Science and Technology","doi-asserted-by":"crossref","award":["QNKT16-03"],"award-info":[{"award-number":["QNKT16-03"]}],"id":[{"id":"10.13039\/501100011349","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Applied Thermal Engineering"],"published-print":{"date-parts":[[2016,8]]},"DOI":"10.1016\/j.applthermaleng.2016.07.043","type":"journal-article","created":{"date-parts":[[2016,7,8]],"date-time":"2016-07-08T12:26:18Z","timestamp":1467980778000},"page":"863-869","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":28,"special_numbering":"C","title":["Cooling characteristics of cooking oil using water mist during fire extinguishment"],"prefix":"10.1016","volume":"107","author":[{"given":"Tian-wei","family":"Zhang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhi-yue","family":"Han","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhi-ming","family":"Du","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kai","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ze-lin","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"2","key":"10.1016\/j.applthermaleng.2016.07.043_b0005","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1023\/A:1015395001403","article-title":"Cooking oil: a home fire hazard in Alberta, Canada","volume":"33","author":"Wijayasinghe","year":"1997","journal-title":"Fire Technol."},{"issue":"2","key":"10.1016\/j.applthermaleng.2016.07.043_b0010","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1177\/0734904110385064","article-title":"Experimental study of new gas-solid composite particles in extinguishing cooking oil fires","volume":"29","author":"Ni","year":"2011","journal-title":"J. Fire Sci."},{"key":"10.1016\/j.applthermaleng.2016.07.043_b0015","first-page":"35","article-title":"Asphalt fume exposures during the application of hot asphalt to roofs","volume":"6","author":"John","year":"2003","journal-title":"National Inst. Occup. Saf. Health"},{"issue":"5","key":"10.1016\/j.applthermaleng.2016.07.043_b0020","first-page":"951","article-title":"Study on the suppressing effectiveness of water mist spray parameters in cooking oil fire","volume":"26","author":"Zhang","year":"2010","journal-title":"Shenyang Jianzhu Daxue Xuebao"},{"key":"10.1016\/j.applthermaleng.2016.07.043_b0025","doi-asserted-by":"crossref","first-page":"2804","DOI":"10.4028\/www.scientific.net\/AMM.166-169.2804","article-title":"The experimental study on extinguishing cooking oil fires by water mist","volume":"166\u2013169","author":"Chen","year":"2012","journal-title":"Appl. Mech. Mater."},{"key":"10.1016\/j.applthermaleng.2016.07.043_b0030","doi-asserted-by":"crossref","first-page":"1298","DOI":"10.3801\/IAFSS.FSS.11-1298","article-title":"Experimental evaluation on performance of open kitchen fire suppression systems","volume":"11","author":"Chow","year":"2014","journal-title":"Fire Saf. Sci."},{"issue":"3","key":"10.1016\/j.applthermaleng.2016.07.043_b0035","doi-asserted-by":"crossref","first-page":"1293","DOI":"10.1016\/j.jhazmat.2006.04.050","article-title":"Experimental study of thin-layer boilover in large-scale pool fires","volume":"137","author":"Ferrero","year":"2006","journal-title":"J. Hazard. Mater."},{"key":"10.1016\/j.applthermaleng.2016.07.043_b0040","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.firesaf.2006.05.008","article-title":"Large-scale boilover experiments using crude oil","volume":"41","author":"Koseki","year":"2006","journal-title":"Fire Saf. J."},{"key":"10.1016\/j.applthermaleng.2016.07.043_b0045","doi-asserted-by":"crossref","first-page":"469","DOI":"10.3801\/IAFSS.FSS.7-469","article-title":"Application of water sprays to industrial oil cooker fire","volume":"7","author":"Nam","year":"2003","journal-title":"Fire Saf. J."},{"issue":"5","key":"10.1016\/j.applthermaleng.2016.07.043_b0050","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1016\/j.firesaf.2004.02.001","article-title":"Boilover upon suppression of cooking oil fire by water spray","volume":"39","author":"Nam","year":"2004","journal-title":"Fire Saf. J."},{"issue":"4","key":"10.1016\/j.applthermaleng.2016.07.043_b0055","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1023\/B:FIRE.0000039161.18616.86","article-title":"Extinguishment of cooking oil fires by water mist fire suppression systems","volume":"40","author":"Liu","year":"2004","journal-title":"Fire Technol."},{"issue":"6","key":"10.1016\/j.applthermaleng.2016.07.043_b0060","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1016\/j.jlp.2005.12.009","article-title":"Characteristics of large cooking oil pool fires and their extinguishment by water mist","volume":"19","author":"Liu","year":"2006","journal-title":"J. Loss Prev. Process Ind."},{"issue":"4","key":"10.1016\/j.applthermaleng.2016.07.043_b0065","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.firesaf.2007.08.004","article-title":"Cooling characteristics of hot oil pool by water mist during fire suppression","volume":"43","author":"Liu","year":"2008","journal-title":"Fire Saf. J."},{"key":"10.1016\/j.applthermaleng.2016.07.043_b0070","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/S0065-2377(08)60252-5","article-title":"Rapid phase transitions from liquid to vapor","author":"Reid","year":"1983","journal-title":"Adv. Chem. Eng."},{"issue":"3","key":"10.1016\/j.applthermaleng.2016.07.043_b0075","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1063\/1.555734","article-title":"The homogeneous nucleation limits of liquids","volume":"14","author":"Avedisian","year":"1985","journal-title":"J. Phys. Chem. Ref. Data"},{"key":"10.1016\/j.applthermaleng.2016.07.043_b0080","series-title":"Experimental Study on Oil Pool Fire Suppression Effectiveness of Water Mist with Additives","author":"Zhang","year":"2015"},{"issue":"1","key":"10.1016\/j.applthermaleng.2016.07.043_b0085","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.firesaf.2006.06.008","article-title":"A study of portable water mist fire extinguishers used for extinguishment of multiple fire types","volume":"42","author":"Liu","year":"2007","journal-title":"Fire Saf. J."},{"key":"10.1016\/j.applthermaleng.2016.07.043_b0090","series-title":"Lange\u2019s Handbook of Chemistry","first-page":"8","author":"Speight","year":"1999"},{"key":"10.1016\/j.applthermaleng.2016.07.043_b0095","first-page":"431","article-title":"High speed aerodynamics and jet propulsion. volume II. combustion processes","author":"Lewis","year":"1956","journal-title":"High Speed Aerodynam. Jet Propul."}],"container-title":["Applied Thermal Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1359431116311723?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1359431116311723?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2020,5,17]],"date-time":"2020-05-17T01:00:09Z","timestamp":1589677209000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1359431116311723"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,8]]},"references-count":19,"alternative-id":["S1359431116311723"],"URL":"https:\/\/doi.org\/10.1016\/j.applthermaleng.2016.07.043","relation":{},"ISSN":["1359-4311"],"issn-type":[{"value":"1359-4311","type":"print"}],"subject":[],"published":{"date-parts":[[2016,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Cooling characteristics of cooking oil using water mist during fire extinguishment","name":"articletitle","label":"Article Title"},{"value":"Applied Thermal Engineering","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.applthermaleng.2016.07.043","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}