{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T16:04:54Z","timestamp":1759334694359,"version":"build-2065373602"},"reference-count":17,"publisher":"Elsevier BV","issue":"8","license":[{"start":{"date-parts":[[2007,11,1]],"date-time":"2007-11-01T00:00:00Z","timestamp":1193875200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2007,11,1]],"date-time":"2007-11-01T00:00:00Z","timestamp":1193875200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Archives of Medical Research"],"published-print":{"date-parts":[[2007,11]]},"DOI":"10.1016\/j.arcmed.2007.06.002","type":"journal-article","created":{"date-parts":[[2007,8,27]],"date-time":"2007-08-27T10:57:05Z","timestamp":1188212225000},"page":"853-857","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Treatment of Seven Patients with Coarctation of the Aorta Treated Using a Mexican-made Platinum\/Iridium Stent"],"prefix":"10.1016","volume":"38","author":[{"given":"Arturo","family":"Abundes-Velasco","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlos","family":"Zabal-Cerdeira","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jos\u00e9 Antonio","family":"Garc\u00eda-Montes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manuel Odin","family":"De los R\u00edos-Ibarra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joel Estrada","family":"Gallegos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Germ\u00e1n Quintana","family":"Pe\u00f1a","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.arcmed.2007.06.002_bib1","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1053\/pcsu.2002.31488","article-title":"Complications of coarctation repair","volume":"5","author":"Serfontein","year":"2002","journal-title":"Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu"},{"key":"10.1016\/j.arcmed.2007.06.002_bib2","first-page":"339","article-title":"Percutaneous transluminal angioplasty in aortic coarctation in adolescents and adults. Mid-term results","volume":"62","author":"Ledesma-Velasco","year":"1992","journal-title":"Arch Inst Cardiol Mex"},{"key":"10.1016\/j.arcmed.2007.06.002_bib3","first-page":"399","article-title":"Stents in aortic coarctation. Immediate results","volume":"67","author":"Ledesma","year":"1997","journal-title":"Arch Inst Cardiol Mex"},{"key":"10.1016\/j.arcmed.2007.06.002_bib4","series-title":"Las m\u00faltiples facetas en investigaci\u00f3n en salud, proyectos estrat\u00e9gicos del Instituto Mexicano del Seguro Social","article-title":"Experimentaci\u00f3n con un stent de platino fabricado en M\u00e9xico. En Garc\u00eda MC, Reyes MH, Viniegra VI, editores","author":"Abundes","year":"2001"},{"key":"10.1016\/j.arcmed.2007.06.002_bib5","first-page":"127","article-title":"A new platinum balloon-expandable stent (Angiostent) mounted on high pressure ballon: acute and late results in atherogenic swin model","volume":"7","author":"Hijazi","year":"1995","journal-title":"J Invasive Cardiol"},{"key":"10.1016\/j.arcmed.2007.06.002_bib6","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1016\/S0300-8932(02)76785-7","article-title":"Resultados inmediatos y a largo plazo del implante de un nuevo stent coronario de platino (stent Atlas) en pacientes con enfermedad arterial coronaria","volume":"55","author":"Abundes","year":"2002","journal-title":"Rev Esp Cardiol"},{"key":"10.1016\/j.arcmed.2007.06.002_bib7","first-page":"423","article-title":"Surgical management of coarctation of the aorta","volume":"42","author":"Ravikumar","year":"1990","journal-title":"Indian Heart J"},{"key":"10.1016\/j.arcmed.2007.06.002_bib8","first-page":"404","article-title":"Coarctation repair with prosthetic material: surgical experience with aneurism formation","volume":"4","author":"Napoleone","year":"2003","journal-title":"Ital Heart J"},{"key":"10.1016\/j.arcmed.2007.06.002_bib9","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1161\/01.CIR.87.3.793","article-title":"Comparison of angioplasty and surgery for unoperated coarctation of the aorta","volume":"87","author":"Shaddy","year":"1993","journal-title":"Circulation"},{"key":"10.1016\/j.arcmed.2007.06.002_bib10","first-page":"20","article-title":"Balloon angioplasty in aortic coarctation: a multicentric study in Mexico","volume":"72","author":"Munayer-Calderon","year":"2002","journal-title":"Arch Cardiol Mex"},{"key":"10.1016\/j.arcmed.2007.06.002_bib11","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1136\/heart.89.1.77","article-title":"The adult patient with native coarctation of the aorta: balloon angioplasty or primary stenting?","volume":"89","author":"Zabal","year":"2003","journal-title":"Heart"},{"key":"10.1016\/j.arcmed.2007.06.002_bib12","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1583\/1074-6218(1995)002<0183:ETIAAC>2.0.CO;2","article-title":"Endovascular techniques in adult aortic coarctation: the use of stents for native and recurrent coarctation repair","volume":"2","author":"Diethrich","year":"1995","journal-title":"J Endovasc Surg"},{"key":"10.1016\/j.arcmed.2007.06.002_bib13","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1136\/heart.84.1.65","article-title":"Stent treatment for coarctation of the aorta: intermediate term follow up and technical considerations","volume":"84","author":"Thanopoulos","year":"2000","journal-title":"Heart"},{"key":"10.1016\/j.arcmed.2007.06.002_bib14","doi-asserted-by":"crossref","first-page":"1847","DOI":"10.1016\/S0735-1097(97)00408-7","article-title":"Use of balloon-expandable stents for coarctation of the aorta: initial results and intermediate-term follow-up","volume":"30","author":"Ebeid","year":"1997","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.arcmed.2007.06.002_bib15","first-page":"72","article-title":"Angioplasty in congenital aortic coarctaion in adults with balloon and endovascular protests: in mediate results and 6 months follow-up)","volume":"70","author":"Uruchurtu","year":"2000","journal-title":"Arch Inst Cardiol Mex"},{"key":"10.1016\/j.arcmed.2007.06.002_bib16","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1016\/j.jacc.2005.11.061","article-title":"Covered Cheatham-platinum stents for aortic coarctation: early and intermediate-term results","volume":"47","author":"Tzifa","year":"2006","journal-title":"JACC"},{"key":"10.1016\/j.arcmed.2007.06.002_bib17","doi-asserted-by":"crossref","first-page":"2728","DOI":"10.1093\/eurheartj\/ehi491","article-title":"Results and mid\u2013long-term follow-up of stent implantation for native and recurrent coarctation of the aorta","volume":"26","author":"Chessa","year":"2005","journal-title":"Eur Heart J"}],"container-title":["Archives of Medical Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0188440907002019?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0188440907002019?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T19:34:36Z","timestamp":1759260876000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0188440907002019"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,11]]},"references-count":17,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2007,11]]}},"alternative-id":["S0188440907002019"],"URL":"https:\/\/doi.org\/10.1016\/j.arcmed.2007.06.002","relation":{},"ISSN":["0188-4409"],"issn-type":[{"type":"print","value":"0188-4409"}],"subject":[],"published":{"date-parts":[[2007,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Treatment of Seven Patients with Coarctation of the Aorta Treated Using a Mexican-made Platinum\/Iridium Stent","name":"articletitle","label":"Article Title"},{"value":"Archives of Medical Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arcmed.2007.06.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2007 IMSS. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}