{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,23]],"date-time":"2026-04-23T08:57:01Z","timestamp":1776934621266,"version":"3.51.2"},"reference-count":19,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2019,12,1]],"date-time":"2019-12-01T00:00:00Z","timestamp":1575158400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,12,1]],"date-time":"2019-12-01T00:00:00Z","timestamp":1575158400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2019,10,10]],"date-time":"2019-10-10T00:00:00Z","timestamp":1570665600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["arthroplastytoday.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroplasty Today"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1016\/j.artd.2019.10.001","type":"journal-article","created":{"date-parts":[[2019,11,20]],"date-time":"2019-11-20T19:04:32Z","timestamp":1574276672000},"page":"384-388","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"title":["Total hip replacement failure due to adverse local tissue reaction from both ceramic abrasive wear and trunnion corrosion"],"prefix":"10.1016","volume":"5","author":[{"given":"William Christian","family":"Thomas","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hernan A.","family":"Prieto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"17","key":"10.1016\/j.artd.2019.10.001_bib1","doi-asserted-by":"crossref","first-page":"1489","DOI":"10.2106\/JBJS.17.00345","article-title":"Trunnionosis in total hip arthroplasty","volume":"99","author":"Weiser","year":"2017","journal-title":"J\u00a0Bone Joint Surg Am"},{"issue":"4","key":"10.1016\/j.artd.2019.10.001_bib2","doi-asserted-by":"crossref","first-page":"e92","DOI":"10.2106\/JBJS.CC.N.00242","article-title":"Extreme cobalt toxicity: bearing the brunt of a failed ceramic liner","volume":"5","author":"Griffiths","year":"2015","journal-title":"JBJS Case Connect"},{"issue":"1","key":"10.1016\/j.artd.2019.10.001_bib3","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1007\/s00402-002-0449-9","article-title":"Massive metallosis after revision of a fractured ceramic head onto a metal head","volume":"123","author":"Matziolis","year":"2003","journal-title":"Arch Orthop Trauma Surg"},{"issue":"1","key":"10.1016\/j.artd.2019.10.001_bib4","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1302\/0301-620X.95B1.30060","article-title":"Fatal cardiomyopathy after revision total hip replacement for fracture of a ceramic liner","volume":"95-B","author":"Zywiel","year":"2013","journal-title":"Bone Joint J"},{"key":"10.1016\/j.artd.2019.10.001_bib5","first-page":"9123684","article-title":"Fatal cobalt toxicity after a non-metal-on-metal total hip arthroplasty","volume":"2017","author":"Peters","year":"2017","journal-title":"Case Rep Orthop"},{"issue":"8","key":"10.1016\/j.artd.2019.10.001_bib6","doi-asserted-by":"crossref","first-page":"1012","DOI":"10.1302\/0301-620X.99B8.BJJ-2017-0019.R1","article-title":"Ceramic-on-ceramic bearing fractures in total hip arthroplasty","volume":"99-B","author":"Howard","year":"2017","journal-title":"Bone Joint J"},{"issue":"4","key":"10.1016\/j.artd.2019.10.001_bib7","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.artd.2015.10.002","article-title":"Cardiac cobaltism: a rare complication after bilateral metal-on-metal total hip arthroplasty","volume":"1","author":"Martin","year":"2015","journal-title":"Arthroplast Today"},{"issue":"6","key":"10.1016\/j.artd.2019.10.001_bib8","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1016\/j.arth.2015.01.041","article-title":"Long term results of liner polyethylene cementation technique in revision for peri-acetabular osteolysis","volume":"30","author":"Rivkin","year":"2015","journal-title":"J\u00a0Arthroplasty"},{"issue":"1","key":"10.1016\/j.artd.2019.10.001_bib9","doi-asserted-by":"crossref","first-page":"61","DOI":"10.5301\/hipint.5000191","article-title":"Outcomes of polyethylene liner cementation into a fixed metal acetabular shell with minimum follow-up of 7 years","volume":"25","author":"Park","year":"2015","journal-title":"Hip Int"},{"issue":"3","key":"10.1016\/j.artd.2019.10.001_bib10","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1080\/17453674.2018.1440455","article-title":"Revision surgery of metal-on-metal hip arthroplasties for adverse reactions to metal debris: a clinical update","volume":"89","author":"Matharu","year":"2018","journal-title":"Acta Orthop"},{"issue":"3","key":"10.1016\/j.artd.2019.10.001_bib11","doi-asserted-by":"crossref","first-page":"41","DOI":"10.5312\/wjo.v9.i3.41","volume":"9","author":"Hung","year":"2018","journal-title":"World J Orthop"},{"key":"10.1016\/j.artd.2019.10.001_bib12","series-title":"14th Annual Report: National Joint Registry for England, Wales, Northern Ireland and the Isle of Man","year":"2016"},{"issue":"2","key":"10.1016\/j.artd.2019.10.001_bib13","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1016\/j.arth.2017.09.040","article-title":"Clinical and radiographic outcomes at 25-30 years of a hip stem fully coated with hydroxylapatite","volume":"33","author":"Jacquot","year":"2018","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.artd.2019.10.001_bib14","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.ejro.2014.11.001","article-title":"Metallosis: a diagnosis not only in patients with metal-on-metal prostheses","volume":"2","author":"Oliveira","year":"2015","journal-title":"Eur J Radiol Open"},{"issue":"1 Suppl A","key":"10.1016\/j.artd.2019.10.001_bib15","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1302\/0301-620X.100B1.BJJ-2017-0569.R1","article-title":"Trunnion corrosion","volume":"100-B","author":"Berstock","year":"2018","journal-title":"Bone Joint J"},{"issue":"9","key":"10.1016\/j.artd.2019.10.001_bib16","doi-asserted-by":"crossref","first-page":"874","DOI":"10.1080\/15563650.2016.1214274","article-title":"Fatal cobalt toxicity after total hip arthroplasty revision for fractured ceramic components","volume":"54","author":"Fox","year":"2016","journal-title":"Clin Toxicol"},{"issue":"4","key":"10.1016\/j.artd.2019.10.001_bib17","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1016\/j.arth.2014.11.023","article-title":"Gross trunnion failure after primary total hip arthroplasty","volume":"30","author":"Banerjee","year":"2015","journal-title":"J\u00a0Arthroplasty"},{"issue":"1","key":"10.1016\/j.artd.2019.10.001_bib18","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1016\/j.arth.2015.07.039","article-title":"Diagnosis and management of adverse local tissue reactions secondary to corrosion at the head-neck junction in patients with metal on polyethylene bearings","volume":"31","author":"Plummer","year":"2016","journal-title":"J\u00a0Arthroplasty"},{"issue":"8","key":"10.1016\/j.artd.2019.10.001_bib19","doi-asserted-by":"crossref","first-page":"2631","DOI":"10.1016\/j.arth.2018.03.061","article-title":"The fate of elevated metal ion levels after revision surgery for head-neck taper corrosion in patients with metal-on-polyethylene total hip arthroplasty","volume":"33","author":"Kwon","year":"2018","journal-title":"J\u00a0Arthroplasty"}],"container-title":["Arthroplasty Today"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352344119301384?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352344119301384?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,6]],"date-time":"2025-11-06T18:06:05Z","timestamp":1762452365000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2352344119301384"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12]]},"references-count":19,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["S2352344119301384"],"URL":"https:\/\/doi.org\/10.1016\/j.artd.2019.10.001","relation":{},"ISSN":["2352-3441"],"issn-type":[{"value":"2352-3441","type":"print"}],"subject":[],"published":{"date-parts":[[2019,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Total hip replacement failure due to adverse local tissue reaction from both ceramic abrasive wear and trunnion corrosion","name":"articletitle","label":"Article Title"},{"value":"Arthroplasty Today","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.artd.2019.10.001","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons.","name":"copyright","label":"Copyright"}]}}