{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T08:54:59Z","timestamp":1760864099771,"version":"3.37.3"},"reference-count":30,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2020,12,1]],"date-time":"2020-12-01T00:00:00Z","timestamp":1606780800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,12,1]],"date-time":"2020-12-01T00:00:00Z","timestamp":1606780800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2020,7,15]],"date-time":"2020-07-15T00:00:00Z","timestamp":1594771200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000069","name":"National Institute of Arthritis and Musculoskeletal and Skin Diseases","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000069","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["R01AR064840"],"award-info":[{"award-number":["R01AR064840"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.com.au","clinicalkey.es","clinicalkey.com","arthroplastytoday.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroplasty Today"],"published-print":{"date-parts":[[2020,12]]},"DOI":"10.1016\/j.artd.2020.07.019","type":"journal-article","created":{"date-parts":[[2020,8,26]],"date-time":"2020-08-26T16:54:45Z","timestamp":1598460885000},"page":"694-698","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":7,"title":["Multiacquisition Variable-Resonance Image Combination Magnetic Resonance Imaging Used to Study Detailed Bone Apposition and Fixation of an Additively Manufactured Cementless Acetabular Shell"],"prefix":"10.1016","volume":"6","author":[{"given":"Vignesh K.","family":"Alamanda","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ivan","family":"De Martino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hollis G.","family":"Potter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthew F.","family":"Koff","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9495-8137","authenticated-orcid":false,"given":"Bin","family":"Lin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ahava","family":"Muskat","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Geoffrey H.","family":"Westrich","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"2","key":"10.1016\/j.artd.2020.07.019_bib1","first-page":"e16","article-title":"Total hip arthroplasty - over 100 years of operative history","volume":"3","author":"Knight","year":"2011","journal-title":"Orthop Rev (Pavia)"},{"issue":"2","key":"10.1016\/j.artd.2020.07.019_bib2","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1007\/s00264-010-1198-y","article-title":"Cementless acetabular revision: past, present, and future. Revision total hip arthroplasty: the acetabular side using cementless implants","volume":"35","author":"Pulido","year":"2011","journal-title":"Int Orthop"},{"issue":"5","key":"10.1016\/j.artd.2020.07.019_bib3","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1302\/0301-620X.72B5.2211749","article-title":"The effect of improved cementing techniques on component loosening in total hip replacement. An 11-year radiographic review","volume":"72","author":"Mulroy","year":"1990","journal-title":"J\u00a0Bone Joint Surg Br"},{"issue":"12 Suppl 2","key":"10.1016\/j.artd.2020.07.019_bib4","article-title":"Review of the evolution of the cementless acetabular cup","volume":"31","author":"Ries","year":"2008","journal-title":"Orthopedics"},{"issue":"2","key":"10.1016\/j.artd.2020.07.019_bib5","doi-asserted-by":"crossref","first-page":"65","DOI":"10.5371\/hp.2016.28.2.65","article-title":"Implant design in cementless hip arthroplasty","volume":"28","author":"Kim","year":"2016","journal-title":"Hip Pelvis"},{"issue":"3","key":"10.1016\/j.artd.2020.07.019_bib6","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1016\/j.arth.2013.07.037","article-title":"Uncemented porous tantalum acetabular components: early follow-up and failures in 613 primary total hip arthroplasties","volume":"29","author":"Noiseux","year":"2014","journal-title":"J\u00a0Arthroplasty"},{"issue":"5","key":"10.1016\/j.artd.2020.07.019_bib7","doi-asserted-by":"crossref","first-page":"505","DOI":"10.4103\/0019-5413.101032","article-title":"Osseous integration in porous tantalum implants","volume":"46","author":"Paganias","year":"2012","journal-title":"Indian J Orthop"},{"issue":"3","key":"10.1016\/j.artd.2020.07.019_bib8","first-page":"185","article-title":"Emerging technologies in arthroplasty: additive manufacturing","volume":"27","author":"Banerjee","year":"2014","journal-title":"J\u00a0Knee Surg"},{"issue":"4","key":"10.1016\/j.artd.2020.07.019_bib9","doi-asserted-by":"crossref","first-page":"e390","DOI":"10.3928\/01477447-20130327-10","article-title":"Excellent results of primary THA using a highly porous titanium cup","volume":"36","author":"Naziri","year":"2013","journal-title":"Orthopedics"},{"key":"10.1016\/j.artd.2020.07.019_bib10","series-title":"InTech","article-title":"Titanium as a Biomaterial for Implants. Recent Advances in Arthroplasty","author":"Oldani","year":"2012"},{"year":"2018","series-title":"Trident II acetabular system design rationale","key":"10.1016\/j.artd.2020.07.019_bib11"},{"issue":"11 Supple A","key":"10.1016\/j.artd.2020.07.019_bib12","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1302\/0301-620X.96B11.34342","article-title":"Large diameter femoral heads: is bigger always better?","volume":"96-B","author":"Cooper","year":"2014","journal-title":"Bone Joint J"},{"issue":"6","key":"10.1016\/j.artd.2020.07.019_bib13","doi-asserted-by":"crossref","first-page":"912","DOI":"10.1302\/0301-620X.76B6.7983118","article-title":"Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses","volume":"76","author":"Karrholm","year":"1994","journal-title":"J\u00a0Bone Joint Surg Br"},{"issue":"1","key":"10.1016\/j.artd.2020.07.019_bib14","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1055\/s-0034-1396763","article-title":"Radiographic evaluation of hip implants","volume":"19","author":"Chang","year":"2015","journal-title":"Semin Musculoskelet Radiol"},{"issue":"14","key":"10.1016\/j.artd.2020.07.019_bib15","doi-asserted-by":"crossref","first-page":"2912","DOI":"10.1016\/j.jbiomech.2008.07.035","article-title":"Handling modular hip implants in model-based RSA: combined stem-head models","volume":"41","author":"Prins","year":"2008","journal-title":"J\u00a0Biomech"},{"issue":"2","key":"10.1016\/j.artd.2020.07.019_bib16","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1302\/0301-620X.81B2.0810289","article-title":"Improving the detection of acetabular osteolysis using oblique radiographs","volume":"81","author":"Southwell","year":"1999","journal-title":"J\u00a0Bone Joint Surg Br"},{"issue":"8","key":"10.1016\/j.artd.2020.07.019_bib17","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.2106\/00004623-200308000-00013","article-title":"Radiographic definition of pelvic osteolysis following total hip arthroplasty","volume":"85","author":"Claus","year":"2003","journal-title":"J\u00a0Bone Joint Surg Am"},{"issue":"4","key":"10.1016\/j.artd.2020.07.019_bib18","doi-asserted-by":"crossref","first-page":"609","DOI":"10.2106\/00004623-200204000-00016","article-title":"Use of helical computed tomography for the assessment of acetabular osteolysis after total hip arthroplasty","volume":"84","author":"Puri","year":"2002","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.artd.2020.07.019_bib19","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1097\/01.blo.0000129345.22322.8a","article-title":"Computed tomography to assess pelvic lysis after total hip replacement","author":"Claus","year":"2004","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.artd.2020.07.019_bib20","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1097\/01.blo.0000164028.14504.46","article-title":"Comparison of CT, MRI, and radiographs in assessing pelvic osteolysis: a cadaveric study","volume":"437","author":"Walde","year":"2005","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"10.1016\/j.artd.2020.07.019_bib21","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1016\/j.orthres.2005.02.007","article-title":"Magnetic resonance imaging in the evaluation of periprosthetic acetabular osteolysis: a cadaveric study","volume":"23","author":"Weiland","year":"2005","journal-title":"J\u00a0Orthop Res"},{"issue":"3","key":"10.1016\/j.artd.2020.07.019_bib22","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/j.ocl.2006.03.003","article-title":"Magnetic resonance imaging of joint arthroplasty","volume":"37","author":"Potter","year":"2006","journal-title":"Orthop Clin North Am"},{"issue":"5","key":"10.1016\/j.artd.2020.07.019_bib23","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1007\/s00264-007-0364-3","article-title":"Total hip arthroplasties: what are the reasons for revision?","volume":"32","author":"Ulrich","year":"2008","journal-title":"Int Orthop"},{"issue":"1","key":"10.1016\/j.artd.2020.07.019_bib24","doi-asserted-by":"crossref","first-page":"140","DOI":"10.2214\/AJR.13.11785","article-title":"Metal artifact reduction with MAVRIC SL at 3-T MRI in patients with hip arthroplasty","volume":"204","author":"Choi","year":"2015","journal-title":"AJR Am J Roentgenol"},{"issue":"9","key":"10.1016\/j.artd.2020.07.019_bib25","doi-asserted-by":"crossref","first-page":"2085","DOI":"10.1097\/CORR.0000000000000772","article-title":"What is the diagnostic accuracy of MRI for component loosening in THA?","volume":"477","author":"Burge","year":"2019","journal-title":"Clin Orthop Relat Res"},{"issue":"5","key":"10.1016\/j.artd.2020.07.019_bib26","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1002\/jmri.24668","article-title":"In\u00a0vitro assessment of knee MRI in the presence of metal implants comparing MAVRIC-SL and conventional fast spin echo sequences at 1.5 and 3 T field strength","volume":"41","author":"Liebl","year":"2015","journal-title":"J\u00a0Magn Reson Imaging"},{"key":"10.1016\/j.artd.2020.07.019_bib27","unstructured":"Australian Orthopedic Association national Joint Replacement Registry, 2019 Annual Report.\""},{"issue":"10","key":"10.1016\/j.artd.2020.07.019_bib28","doi-asserted-by":"crossref","first-page":"1700187","DOI":"10.1002\/advs.201700187","article-title":"Additive manufacturing: unlocking the evolution of energy materials","volume":"4","author":"Zhakeyev","year":"2017","journal-title":"Adv Sci (Weinh)"},{"issue":"1","key":"10.1016\/j.artd.2020.07.019_bib29","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.ocl.2018.08.009","article-title":"Additive manufacturing in total joint arthroplasty","volume":"50","author":"Narra","year":"2019","journal-title":"Orthop Clin North Am"},{"issue":"8","key":"10.1016\/j.artd.2020.07.019_bib30","doi-asserted-by":"crossref","first-page":"2254","DOI":"10.1016\/j.arth.2020.03.036","article-title":"Porous Coatings in retrieved acetabular components","volume":"35","author":"Baral","year":"2020","journal-title":"J\u00a0Arthroplasty"}],"container-title":["Arthroplasty Today"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352344120301382?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352344120301382?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,11,2]],"date-time":"2024-11-02T12:07:28Z","timestamp":1730549248000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2352344120301382"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12]]},"references-count":30,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["S2352344120301382"],"URL":"https:\/\/doi.org\/10.1016\/j.artd.2020.07.019","relation":{},"ISSN":["2352-3441"],"issn-type":[{"type":"print","value":"2352-3441"}],"subject":[],"published":{"date-parts":[[2020,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Multiacquisition Variable-Resonance Image Combination Magnetic Resonance Imaging Used to Study Detailed Bone Apposition and Fixation of an Additively Manufactured Cementless Acetabular Shell","name":"articletitle","label":"Article Title"},{"value":"Arthroplasty Today","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.artd.2020.07.019","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons.","name":"copyright","label":"Copyright"}]}}