{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T16:40:06Z","timestamp":1786984806213,"version":"build-2736575974"},"reference-count":32,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2023,12,1]],"date-time":"2023-12-01T00:00:00Z","timestamp":1701388800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,12,1]],"date-time":"2023-12-01T00:00:00Z","timestamp":1701388800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T00:00:00Z","timestamp":1697328000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["arthroplastytoday.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroplasty Today"],"published-print":{"date-parts":[[2023,12]]},"DOI":"10.1016\/j.artd.2023.101270","type":"journal-article","created":{"date-parts":[[2023,12,3]],"date-time":"2023-12-03T00:46:33Z","timestamp":1701564393000},"page":"101270","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":5,"special_numbering":"C","title":["Cementation of a Metal Dual Mobility Liner in Patients Undergoing Revision Total Hip Arthroplasty"],"prefix":"10.1016","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9647-7193","authenticated-orcid":false,"given":"Zhongming","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandeep S.","family":"Bains","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeremy A.","family":"Dubin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oliver C.","family":"Sax","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory A.","family":"Gilson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Danielle A.","family":"Jacobstein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Austin","family":"Nabet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Nace","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5651-2625","authenticated-orcid":false,"given":"Ronald E.","family":"Delanois","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.artd.2023.101270_bib1","doi-asserted-by":"crossref","first-page":"2088","DOI":"10.1016\/j.arth.2017.02.046","article-title":"Current epidemiology of revision total hip arthroplasty in the United States: national inpatient sample 2009 to 2013","volume":"32","author":"Gwam","year":"2017","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.artd.2023.101270_bib2","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1007\/s11999-008-0566-z","article-title":"Why revision total hip arthroplasty fails","author":"Springer","year":"2009","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.artd.2023.101270_bib3","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1016\/S0140-6736(18)31665-9","article-title":"How long does a hip replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up","volume":"393","author":"Evans","year":"2019","journal-title":"Lancet"},{"key":"10.1016\/j.artd.2023.101270_bib4","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1016\/j.arth.2006.10.011","article-title":"Cementation of a polyethylene liner into a metal shell","volume":"22","author":"Delanois","year":"2007","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.artd.2023.101270_bib5","doi-asserted-by":"crossref","first-page":"243","DOI":"10.5435\/00124635-200805000-00002","article-title":"Isolated acetabular liner exchange","volume":"16","author":"Lombardi","year":"2008","journal-title":"J Am Acad Orthop Surg"},{"key":"10.1016\/j.artd.2023.101270_bib6","doi-asserted-by":"crossref","first-page":"1397","DOI":"10.2106\/JBJS.19.01441","article-title":"Intermediate to long-term follow-up of cementing liners into well-fixed acetabular components","volume":"102","author":"Bedard","year":"2020","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.artd.2023.101270_bib7","doi-asserted-by":"crossref","first-page":"634","DOI":"10.1016\/j.arth.2013.07.042","article-title":"Medium-term results of cementation of a highly cross-linked polyethylene liner into a well-fixed acetabular shell in revision hip arthroplasty","volume":"29","author":"Lim","year":"2014","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.artd.2023.101270_bib8","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1002\/jor.22314","article-title":"Cementation of a dual-mobility acetabular component into a well-fixed metal shell during revision total hip arthroplasty: a biomechanical validation","volume":"31","author":"Wegrzyn","year":"2013","journal-title":"J Orthop Res"},{"key":"10.1016\/j.artd.2023.101270_bib9","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/j.artd.2019.05.001","article-title":"Cementation of a monoblock dual mobility bearing in a newly implanted porous revision acetabular component in patients undergoing revision total hip arthroplasty","volume":"5","author":"Gabor","year":"2019","journal-title":"Arthroplast Today"},{"key":"10.1016\/j.artd.2023.101270_bib10","doi-asserted-by":"crossref","first-page":"2561","DOI":"10.1016\/j.arth.2020.05.001","article-title":"Cementation of a dual mobility cup into an existing well-fixed metal shell: a reliable option to manage wear-related recurrent dislocation in patients with high surgical risk","volume":"35","author":"Wegrzyn","year":"2020","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.artd.2023.101270_bib11","doi-asserted-by":"crossref","first-page":"115","DOI":"10.2214\/ajr.180.1.1800115","article-title":"Pictorial essay. Imaging of the painful hip arthroplasty","volume":"180","author":"Keogh","year":"2003","journal-title":"Am J Roentgenol"},{"key":"10.1016\/j.artd.2023.101270_bib12","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1097\/00003086-197906000-00002","article-title":"\u201cModes of failure\u201d of cemented stem-ty","author":"Gruen","year":"1979","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.artd.2023.101270_bib13","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1097\/00003086-197611000-00003","article-title":"Radiological demarcation of cemented sockets in total hip replacement","author":"DeLee","year":"1976","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.artd.2023.101270_bib14","first-page":"356","article-title":"Dual mobility acetabular systems for total hip arthroplasty: a multicenter study and technique report","volume":"37","author":"Salem","year":"2020","journal-title":"Surg Technol Int"},{"key":"10.1016\/j.artd.2023.101270_bib15","doi-asserted-by":"crossref","first-page":"S287","DOI":"10.1016\/j.arth.2019.03.027","article-title":"Multicenter evaluation of a modular dual mobility construct for revision total hip arthroplasty","volume":"34","author":"Huang","year":"2019","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.artd.2023.101270_bib16","doi-asserted-by":"crossref","first-page":"2181","DOI":"10.1007\/s11999-016-4811-6","article-title":"Low frequency of early complications with dual-mobility acetabular cups in cementless primary THA","author":"Chughtai","year":"2016","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.artd.2023.101270_bib17","doi-asserted-by":"crossref","first-page":"090","DOI":"10.1055\/s-0040-1713109","article-title":"Minimum 7-year outcomes of dual mobility acetabular cups in total hip arthroplasty patients","volume":"4","author":"Tarazi","year":"2020","journal-title":"J Hip Surg"},{"key":"10.1016\/j.artd.2023.101270_bib18","doi-asserted-by":"crossref","first-page":"566","DOI":"10.3109\/17453674.2012.742395","article-title":"Dual-mobility cups for revision due to instability are associated with a low rate of re-revisions due to dislocation: 228 patients from the Swedish Hip Arthroplasty Register","volume":"83","author":"Hailer","year":"2012","journal-title":"Acta Orthop"},{"key":"10.1016\/j.artd.2023.101270_bib19","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1302\/0301-620X.100B1.BJJ-2017-0462.R1","article-title":"Outcomes of dual mobility components in total hip arthroplasty: a systematic review of the literature","volume":"100","author":"Darrith","year":"2018","journal-title":"Bone Joint J"},{"key":"10.1016\/j.artd.2023.101270_bib20","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1302\/0301-620X.99B1.BJJ-2016-0398.R1","article-title":"Dislocation following total hip arthroplasty using dual mobility acetabular components","volume":"99","author":"De Martino","year":"2017","journal-title":"Bone Joint J"},{"key":"10.1016\/j.artd.2023.101270_bib21","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1007\/s00590-017-2073-y","article-title":"Risk of revision and dislocation in single, dual mobility and large femoral head total hip arthroplasty: systematic review and network meta-analysis","volume":"28","author":"Pituckanotai","year":"2018","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"10.1016\/j.artd.2023.101270_bib22","first-page":"367","article-title":"An economic evaluation of over 200,000 revision total hip arthroplasties: is the current model sustainable?","volume":"37","author":"DeGouveia","year":"2020","journal-title":"Surg Technol Int"},{"key":"10.1016\/j.artd.2023.101270_bib23","doi-asserted-by":"crossref","first-page":"57","DOI":"10.5301\/hipint.5000295","article-title":"Dual mobility cups: an effective prosthesis in revision total hip arthroplasties for preventing dislocations","volume":"26","author":"Jauregui","year":"2016","journal-title":"HIP Int"},{"key":"10.1016\/j.artd.2023.101270_bib24","doi-asserted-by":"crossref","first-page":"1501","DOI":"10.1016\/j.arth.2017.11.055","article-title":"Cementation of a dual mobility construct in recurrently dislocating and high risk\u00a0patients undergoing revision total arthroplasty","volume":"33","author":"Chalmers","year":"2018","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.artd.2023.101270_bib25","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1016\/j.otsr.2015.05.002","article-title":"Dual mobility cup in revision total hip arthroplasty: dislocation rate and survival after 5 years","volume":"101","author":"Simian","year":"2015","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.artd.2023.101270_sref26","doi-asserted-by":"crossref","first-page":"2463","DOI":"10.1007\/s00264-014-2448-1","article-title":"Cementless dual-mobility cup in total hip arthroplasty revision","volume":"38","author":"Prudhon","year":"2014","journal-title":"Int Orthop"},{"key":"10.1016\/j.artd.2023.101270_sref27","doi-asserted-by":"crossref","DOI":"10.1177\/1120700019873617","article-title":"Cementation of a dual-mobility cup into a well-fixed cementless shell in patients with high risk of dislocation undergoing revision total hip arthroplasty","author":"Moreta","year":"2021","journal-title":"HIP Int"},{"key":"10.1016\/j.artd.2023.101270_bib27","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.arth.2016.03.021","article-title":"Dual-mobility articulations for patients at high risk for dislocation","volume":"31","author":"Plummer","year":"2016","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.artd.2023.101270_bib28","first-page":"46","article-title":"Dissociation of cemented dual mobility socket from the acetabulum in A case of recurrent total hip arthroplasty instability -A novel complication","volume":"8","author":"John","year":"2018","journal-title":"J Orthop Case Rep"},{"key":"10.1016\/j.artd.2023.101270_bib29","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/S0883-5403(03)00287-0","article-title":"Cementation of an acetabular liner into a well-fixed acetabular shell during revision total hip arthroplasty","volume":"18","author":"Springer","year":"2003","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.artd.2023.101270_bib30","doi-asserted-by":"crossref","first-page":"1587","DOI":"10.2106\/00004623-200209000-00011","article-title":"Cementation of a polyethylene liner into a metal shell: factors related to mechanical stability","volume":"84","author":"Bonner","year":"2002","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.artd.2023.101270_bib31","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.2106\/00004623-200306000-00019","article-title":"A\u00a0biomechanical analysis of polyethylene liner cementation into a fixed metal acetabular shell","volume":"85","author":"Haft","year":"2003","journal-title":"J\u00a0Bone Joint Surg Am"}],"container-title":["Arthroplasty Today"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352344123001759?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352344123001759?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,6]],"date-time":"2025-11-06T18:11:09Z","timestamp":1762452669000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2352344123001759"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12]]},"references-count":32,"alternative-id":["S2352344123001759"],"URL":"https:\/\/doi.org\/10.1016\/j.artd.2023.101270","relation":{},"ISSN":["2352-3441"],"issn-type":[{"value":"2352-3441","type":"print"}],"subject":[],"published":{"date-parts":[[2023,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Cementation of a Metal Dual Mobility Liner in Patients Undergoing Revision Total Hip Arthroplasty","name":"articletitle","label":"Article Title"},{"value":"Arthroplasty Today","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.artd.2023.101270","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons.","name":"copyright","label":"Copyright"}],"article-number":"101270"}}