{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T20:10:17Z","timestamp":1790021417523,"version":"4.0.1"},"reference-count":26,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T00:00:00Z","timestamp":1783296000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["arthroplastytoday.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroplasty Today"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1016\/j.artd.2026.102105","type":"journal-article","created":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T19:33:13Z","timestamp":1786217593000},"page":"102105","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Unexpected Metal Ion Elevation and Adverse Tissue Reactions in Trident II Dual Mobility Constructs With Ceramic Heads"],"prefix":"10.1016","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-9682-4966","authenticated-orcid":false,"given":"Henry","family":"Somerby","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carmelo","family":"Burgio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabrielle","family":"Dykhouse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edward","family":"Grabov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aarti","family":"Shenoy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Ramirez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"Vigdorchik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gwo-Chin","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Sculco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.artd.2026.102105_bib1","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1007\/s11420-012-9268-x","article-title":"Total hip arthroplasty at the rothman institute","volume":"8","author":"Austin","year":"2012","journal-title":"HSS J"},{"key":"10.1016\/j.artd.2026.102105_bib2","doi-asserted-by":"crossref","DOI":"10.1111\/ijcp.13806","article-title":"Cost effectiveness analyses of total hip arthroplasty for hip osteoarthritis: a PRISMA systematic review","volume":"75","author":"Agarwal","year":"2021","journal-title":"Int J Clin Pract"},{"key":"10.1016\/j.artd.2026.102105_bib3","series-title":"American Joint Replacement Registry AJRR: 2024 Annual report","year":"2024"},{"issue":"Supp_12","key":"10.1016\/j.artd.2026.102105_bib4","article-title":"Dual mobility utilization trends in the United States: an analysis of the American joint replacement registry","volume":"101-B","author":"Heckmann","year":"2019","journal-title":"Orthop Proc"},{"key":"10.1016\/j.artd.2026.102105_bib5","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1080\/17453674.2018.1542210","article-title":"Dual mobility cups in primary total hip arthroplasties: trend over time in use, patient characteristics, and mid-term revision in 3,038 cases in the Dutch Arthroplasty Register (2007-2016)","volume":"90","author":"Bloemheuvel","year":"2019","journal-title":"Acta Orthop"},{"key":"10.1016\/j.artd.2026.102105_bib6","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1007\/s43465-021-00471-w","article-title":"Dual mobility in total hip arthroplasty: biomechanics, indications and complications-current concepts","volume":"55","author":"Patil","year":"2021","journal-title":"Indian J Orthop"},{"key":"10.1016\/j.artd.2026.102105_bib7","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ocl.2013.08.004","article-title":"Dual mobility in total hip arthroplasty","volume":"45","author":"Plummer","year":"2014","journal-title":"Orthop Clin North Am"},{"key":"10.1016\/j.artd.2026.102105_bib8","doi-asserted-by":"crossref","first-page":"3048","DOI":"10.1007\/s11999-012-2395-3","article-title":"Is a cementless dual mobility socket in primary THA a reasonable option?","volume":"470","author":"Hamadouche","year":"2012","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.artd.2026.102105_bib9","series-title":"Polymeric materials in corrosion inhibition","first-page":"83","article-title":"Chapter 3 - basic concepts of corrosion","author":"Umoren","year":"2022"},{"key":"10.1016\/j.artd.2026.102105_bib10","doi-asserted-by":"crossref","DOI":"10.3390\/jcm10163489","article-title":"The expression levels of toll-like receptors after metallic particle and ion exposition in the synovium of a murine model","volume":"10","author":"Cheng","year":"2021","journal-title":"J Clin Med"},{"key":"10.1016\/j.artd.2026.102105_bib11","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.artd.2021.01.011","article-title":"Severe corrosion of modular dual mobility acetabular components identified during revision total hip arthroplasty","volume":"8","author":"Abdelaal","year":"2021","journal-title":"Arthroplast Today"},{"key":"10.1016\/j.artd.2026.102105_bib12","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.jor.2021.02.018","article-title":"Metal ion levels with use of modular dual mobility constructs: can the evidence guide us on clinical use?","volume":"24","author":"Kamath","year":"2021","journal-title":"J Orthop"},{"key":"10.1016\/j.artd.2026.102105_bib13","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.artd.2018.12.001","article-title":"Asymptomatic intraprosthetic dual mobility cup dislocation with increased metal ion levels","volume":"5","author":"Koper","year":"2019","journal-title":"Arthroplast Today"},{"issue":"7_Supple_B","key":"10.1016\/j.artd.2026.102105_bib14","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1302\/0301-620X.102B7.BJJ-2019-1633.R1","article-title":"Otto Aufranc Award: malseating of modular dual mobility liners","volume":"102-B","author":"Romero","year":"2020","journal-title":"Bone Joint J"},{"key":"10.1016\/j.artd.2026.102105_bib15","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.artd.2021.08.021","article-title":"Serum metal ions in contemporary monoblock and modular dual mobility articulations","volume":"12","author":"Greenberg","year":"2021","journal-title":"Arthroplast Today"},{"key":"10.1016\/j.artd.2026.102105_bib16","doi-asserted-by":"crossref","first-page":"1672","DOI":"10.1002\/jbm.b.33972","article-title":"Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements","volume":"106","author":"Hall","year":"2018","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"10.1016\/j.artd.2026.102105_bib17","doi-asserted-by":"crossref","first-page":"2603","DOI":"10.1016\/j.arth.2021.02.073","article-title":"On the formation mechanism of column damage within modular taper junctions","volume":"36","author":"Zachariah","year":"2021","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.artd.2026.102105_bib18","doi-asserted-by":"crossref","DOI":"10.1016\/j.artd.2024.101543","article-title":"Corrosion of modular dual-mobility acetabular components leading to acetabular bone loss and protrusio","volume":"30","author":"Yang","year":"2024","journal-title":"Arthroplast Today"},{"key":"10.1016\/j.artd.2026.102105_bib19","doi-asserted-by":"crossref","first-page":"976","DOI":"10.1016\/j.artd.2020.08.002","article-title":"Adverse local tissue reaction due to acetabular corrosion in modular dual-mobility constructs","volume":"6","author":"Sonn","year":"2020","journal-title":"Arthroplast Today"},{"key":"10.1016\/j.artd.2026.102105_bib20","doi-asserted-by":"crossref","first-page":"S294.e8","DOI":"10.1016\/j.arth.2020.02.050","article-title":"Patients following revision total hip arthroplasty with modular dual mobility components and cobalt-chromium inner metal head are at risk of increased serum metal ion levels","volume":"35","author":"Civinini","year":"2020","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.artd.2026.102105_bib21","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.artd.2021.09.007","article-title":"Notching of the neck after acetabular constraint necessitating femoral component revision","volume":"12","author":"Bonano","year":"2021","journal-title":"Arthroplast Today"},{"key":"10.1016\/j.artd.2026.102105_bib22","doi-asserted-by":"crossref","first-page":"1265","DOI":"10.1016\/j.arth.2015.02.019","article-title":"A high prevalence of corrosion at the head-neck taper with contemporary zimmer non-cemented femoral hip components","volume":"30","author":"McGrory","year":"2015","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.artd.2026.102105_bib23","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1186\/s13018-021-02492-5","article-title":"Catastrophic failure and metallosis of the acetabular component in total hip arthroplasty","volume":"16","author":"Ozan","year":"2021","journal-title":"J Orthop Surg Res"},{"key":"10.1016\/j.artd.2026.102105_bib24","doi-asserted-by":"crossref","first-page":"186.e9","DOI":"10.1016\/j.arth.2015.07.035","article-title":"Serum metal ion levels following total hip arthroplasty with modular dual mobility components","volume":"31","author":"Matsen Ko","year":"2016","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.artd.2026.102105_bib25","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/j.artd.2022.07.010","article-title":"Failure of screw\/shell interface in the trident II acetabular system in total hip arthroplasty","volume":"17","author":"Ulrich","year":"2022","journal-title":"Arthroplast Today"},{"key":"10.1016\/j.artd.2026.102105_bib26","doi-asserted-by":"crossref","first-page":"2744","DOI":"10.2106\/JBJS.24.01479","article-title":"A randomized controlled trial of a conventional versus modular dual-mobility bearing: are serum metal levels a concern?","volume":"107","author":"DeBenedetti","year":"2025","journal-title":"J Bone Joint Surg Am"}],"container-title":["Arthroplasty Today"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352344126001548?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352344126001548?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T19:35:11Z","timestamp":1790019311000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2352344126001548"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":26,"alternative-id":["S2352344126001548"],"URL":"https:\/\/doi.org\/10.1016\/j.artd.2026.102105","relation":{},"ISSN":["2352-3441"],"issn-type":[{"value":"2352-3441","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Unexpected Metal Ion Elevation and Adverse Tissue Reactions in Trident II Dual Mobility Constructs With Ceramic Heads","name":"articletitle","label":"Article Title"},{"value":"Arthroplasty Today","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.artd.2026.102105","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author(s). Published by Elsevier Inc. on behalf of American Association of Hip and Knee Surgeons.","name":"copyright","label":"Copyright"}],"article-number":"102105"}}