{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T09:30:12Z","timestamp":1793698212904,"version":"4.5.1"},"reference-count":28,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T00:00:00Z","timestamp":1786060800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["arthroplastytoday.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroplasty Today"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1016\/j.artd.2026.102139","type":"journal-article","created":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T19:06:47Z","timestamp":1788808007000},"page":"102139","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Mid-Term Analysis of Serum Metal Ion Levels Comparison Between Monoblock and Modular Dual Mobility Components: A Source for Concern?"],"prefix":"10.1016","volume":"41","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-9682-4966","authenticated-orcid":false,"given":"Henry","family":"Somerby","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Mayman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Allina","family":"Nocon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eoin","family":"Devoy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ittai","family":"Shichman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Sculco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Sculco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.artd.2026.102139_bib1","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1302\/2058-5241.6.200146","article-title":"Adverse reaction to metal debris due to fretting corrosion between the acetabular components of modular dual-mobility constructs in total hip replacement: a systematic review and meta-analysis","volume":"6","author":"French","year":"2021","journal-title":"EFORT Open Rev"},{"key":"10.1016\/j.artd.2026.102139_bib2","doi-asserted-by":"crossref","first-page":"180","DOI":"10.5312\/wjo.v5.i3.180","article-title":"Dual mobility cups in total hip arthroplasty","volume":"5","author":"Martino","year":"2014","journal-title":"WJO"},{"key":"10.1016\/j.artd.2026.102139_bib3","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/j.jor.2024.07.014","article-title":"A comparison of dislocation risk between dual mobility and traditional constructs used in proximal femoral replacement","volume":"59","author":"Zavras","year":"2025","journal-title":"J Orthop"},{"key":"10.1016\/j.artd.2026.102139_bib4","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1302\/0301-620X.107B1.BJJ-2024-0611.R1","article-title":"The risk of dislocation in dual-mobility versus 36 mm heads in primary total hip arthroplasty for osteoarthritis: a propensity-matched analysis from the Danish Hip Arthroplasty Register","volume":"107-B","author":"Hussein","year":"2025","journal-title":"Bone Joint J"},{"key":"10.1016\/j.artd.2026.102139_bib5","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1016\/j.arth.2018.01.030","article-title":"Dual-Mobility constructs in revision total hip arthroplasties","volume":"33","author":"Abdel","year":"2018","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.artd.2026.102139_bib6","doi-asserted-by":"crossref","DOI":"10.2106\/JBJS.OA.25.00141","article-title":"Modern dual mobility implants in total hip arthroplasty: stability, survival, and ion safety evaluation: the comprehensive review","volume":"10","author":"Suarez-Ahedo","year":"2025","journal-title":"JBJS Open Access"},{"key":"10.1016\/j.artd.2026.102139_bib7","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1007\/BF02474667","article-title":"The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip","volume":"7","author":"Charnley","year":"1969","journal-title":"Med & Biol Engng"},{"key":"10.1016\/j.artd.2026.102139_bib8","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1007\/s00264-014-2313-2","article-title":"A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess whether a dual mobility cup has a decreased dislocation risk","volume":"38","author":"Caton","year":"2014","journal-title":"International Orthopaedics (SICOT)"},{"key":"10.1016\/j.artd.2026.102139_bib9","doi-asserted-by":"crossref","first-page":"e273","DOI":"10.3928\/01477447-20230804-01","article-title":"Evolution and new generation of dual mobility cups","volume":"46","author":"Tigani","year":"2023","journal-title":"Orthopedics"},{"key":"10.1016\/j.artd.2026.102139_bib10","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1007\/s00264-016-3361-6","article-title":"Once upon a time\u2026 dual mobility: history","volume":"41","author":"Noyer","year":"2017","journal-title":"International Orthopaedics (SICOT)"},{"key":"10.1016\/j.artd.2026.102139_bib11","doi-asserted-by":"crossref","first-page":"3572","DOI":"10.1007\/s11999-013-3144-y","article-title":"Do monoblock cups improve survivorship, decrease wear, or reduce osteolysis in uncemented total hip arthroplasty?","volume":"471","author":"Halma","year":"2013","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.artd.2026.102139_bib12","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1007\/s11999-014-3791-7","article-title":"Revisions of monoblock metal-on-metal THAs have high early complication rates","volume":"473","author":"Stryker","year":"2015","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.artd.2026.102139_bib13","doi-asserted-by":"crossref","first-page":"2781","DOI":"10.1016\/j.arth.2025.05.124","article-title":"Trends in Medicare Arthroplasty Procedure Volume: projecting from 2025 to 2040","volume":"40","author":"Jones","year":"2025","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.artd.2026.102139_bib14","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1186\/s13018-023-03730-8","article-title":"Modular dual mobility articulation in primary and revision hip arthroplasty: lights and shadows","volume":"18","author":"Moghnie","year":"2023","journal-title":"J Orthop Surg Res"},{"key":"10.1016\/j.artd.2026.102139_bib15","doi-asserted-by":"crossref","first-page":"1773","DOI":"10.1016\/j.arth.2016.01.058","article-title":"Metal-on-Metal total hip arthroplasty at five to twelve years Follow-Up: a concise Follow-Up of a previous report","volume":"31","author":"Greiner","year":"2016","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.artd.2026.102139_bib16","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.jor.2021.02.018","article-title":"Metal ion levels with use of modular dual mobility constructs: can the evidence guide us on clinical use?","volume":"24","author":"Kamath","year":"2021","journal-title":"J Orthop"},{"key":"10.1016\/j.artd.2026.102139_bib17","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.artd.2021.08.021","article-title":"Serum metal ions in Contemporary Monoblock and modular dual mobility articulations","volume":"12","author":"Greenberg","year":"2021","journal-title":"Arthroplast Today"},{"key":"10.1016\/j.artd.2026.102139_bib18","doi-asserted-by":"crossref","first-page":"2922","DOI":"10.1016\/j.arth.2025.05.010","article-title":"Serum metal ion levels in modular dual mobility liners after total hip arthroplasty: a comparison by years and implant manufacturers","volume":"40","author":"Parikh","year":"2025","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.artd.2026.102139_bib19","doi-asserted-by":"crossref","first-page":"1699","DOI":"10.1007\/s00264-025-06507-2","article-title":"Minimum five years outcomes of modular dual mobility in primary total hip arthroplasty: a systematic review","volume":"49","author":"Minelli","year":"2025","journal-title":"Int Orthop"},{"key":"10.1016\/j.artd.2026.102139_bib20","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1007\/s00590-024-04136-w","article-title":"Modular versus monobloc dual mobility components for primary cementless total hip arthroplasty: a systematic review and meta-analysis of implants\u2019 survival, complication rates, clinical and radiographic outcomes","volume":"35","author":"Giovanoulis","year":"2024","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"10.1016\/j.artd.2026.102139_bib21","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1080\/10408444.2017.1392927","article-title":"Biological effects of metal degradation in hip arthroplasties","volume":"48","author":"Granchi","year":"2018","journal-title":"Crit Rev Toxicol"},{"key":"10.1016\/j.artd.2026.102139_bib22","doi-asserted-by":"crossref","first-page":"239","DOI":"10.2106\/JBJS.21.00406","article-title":"Redefining the 3D topography of the acetabular safe Zone: a multivariable Study evaluating prosthetic hip stability","volume":"104","author":"Hevesi","year":"2022","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.artd.2026.102139_bib23","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.arth.2015.07.035","article-title":"Serum metal ion levels following total hip arthroplasty with modular dual mobility components","volume":"31","author":"Matsen Ko","year":"2016","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.artd.2026.102139_bib24","doi-asserted-by":"crossref","first-page":"305","DOI":"10.52198\/24.STI.44.OS1767","article-title":"Are metal ion levels elevated after dual mobility acetabular systems: minimum five-year analyses","volume":"44","author":"Hameed","year":"2024","journal-title":"Surg Technol Int"},{"key":"10.1016\/j.artd.2026.102139_bib25","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1302\/0301-620X.101B9.BJJ-2019-0377.R2","article-title":"Blood metal levels, leucocyte profiles, and cytokine profiles in patients with a modular dual-mobility hip prosthesis: early results from a prospective cohort study","volume":"101-B","author":"Markel","year":"2019","journal-title":"Bone Joint J"},{"key":"10.1016\/j.artd.2026.102139_bib26","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1177\/1120700019865530","article-title":"Response profiles of circulating leukocytes and metal ions in patients with a modular dual-mobility hip implant","volume":"35","author":"Markel","year":"2025","journal-title":"HIP International"},{"key":"10.1016\/j.artd.2026.102139_bib27","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1016\/j.jor.2020.08.019","article-title":"Serum metal ion levels in modular dual mobility acetabular components: a systematic review","volume":"21","author":"Gkiatas","year":"2020","journal-title":"J Orthop"},{"key":"10.1016\/j.artd.2026.102139_bib28","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1016\/S0140-6736(18)31665-9","article-title":"How long does a hip replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up","volume":"393","author":"Evans","year":"2019","journal-title":"Lancet"}],"container-title":["Arthroplasty Today"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352344126001883?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352344126001883?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T09:13:14Z","timestamp":1793697194000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2352344126001883"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":28,"alternative-id":["S2352344126001883"],"URL":"https:\/\/doi.org\/10.1016\/j.artd.2026.102139","relation":{},"ISSN":["2352-3441"],"issn-type":[{"value":"2352-3441","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Mid-Term Analysis of Serum Metal Ion Levels Comparison Between Monoblock and Modular Dual Mobility Components: A Source for Concern?","name":"articletitle","label":"Article Title"},{"value":"Arthroplasty Today","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.artd.2026.102139","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier Inc. on behalf of American Association of Hip and Knee Surgeons.","name":"copyright","label":"Copyright"}],"article-number":"102139"}}