{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T07:06:12Z","timestamp":1790233572675,"version":"4.1.0"},"reference-count":17,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T00:00:00Z","timestamp":1786579200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["arthroplastytoday.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroplasty Today"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1016\/j.artd.2026.102147","type":"journal-article","created":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T06:56:05Z","timestamp":1790232965000},"page":"102147","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Femur-First Cut Kinematically Aligned Unicompartmental Knee Arthroplasty: A Seamless Surgical Technique from UKA to TKA"],"prefix":"10.1016","volume":"41","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7823-7898","authenticated-orcid":false,"given":"Yoshinori","family":"Soda","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mitsuhiro","family":"Nakamura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiya","family":"Kano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.artd.2026.102147_bib1","doi-asserted-by":"crossref","first-page":"4873","DOI":"10.1007\/s00402-024-05574-1","article-title":"Correlation of revision rate of unicompartmental knee arthroplasty with total knee arthroplasty: a meta-analysis of clinical studies and worldwide arthroplasty registers","volume":"144","author":"Stephan Obermayr","year":"2024","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.artd.2026.102147_bib2","first-page":"3323","article-title":"Unicompartmental knee arthroplasty has higher revisions than total knee arthroplasty at long term follow-up: a registry study on 6453 prostheses. Knee Surgery Sports Traumatol","volume":"29","author":"Martino","year":"2021","journal-title":"Arthrosc"},{"key":"10.1016\/j.artd.2026.102147_bib3","doi-asserted-by":"crossref","first-page":"1000","DOI":"10.1007\/s11999-012-2613-z","article-title":"Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category","volume":"471","author":"Howell","year":"2013","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.artd.2026.102147_bib4","doi-asserted-by":"crossref","first-page":"126","DOI":"10.3928\/01477447-20190424-02","article-title":"Calipered kinematically aligned total knee arthroplasty: an accurate technique that improves patient outcomes and implant survival","volume":"42","author":"Howell","year":"2019","journal-title":"Orthopedics"},{"key":"10.1016\/j.artd.2026.102147_bib5","doi-asserted-by":"crossref","first-page":"355","DOI":"10.4236\/ojo.2023.139035","article-title":"Kinematically aligned total knee arthroplasty for valgus osteoarthritis of more than 10\u00b0\u2014Is it still a \u201cchallenging surgery\u201d?","volume":"13","author":"Soda","year":"2023","journal-title":"Open J Orthop"},{"key":"10.1016\/j.artd.2026.102147_bib6","doi-asserted-by":"crossref","first-page":"S43","DOI":"10.2106\/00004623-200100021-00010","article-title":"Three-dimensional morphology of the distal part of the femur viewed in virtual reality","volume":"83","author":"Eckhoff","year":"2001","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.artd.2026.102147_bib7","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/j.knee.2014.12.004","article-title":"Minor varus alignment provides better results than neutral alignment in medial UKA","volume":"22","author":"Vasso","year":"2015","journal-title":"Knee"},{"key":"10.1016\/j.artd.2026.102147_bib8","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/j.otsr.2018.11.005","article-title":"Kinematic alignment technique for medial OXFORD UKA: an in-silico study","volume":"105","author":"Rivi\u00e8re","year":"2019","journal-title":"Orthop Traum Surg Res"},{"key":"10.1016\/j.artd.2026.102147_bib9","doi-asserted-by":"crossref","first-page":"1082","DOI":"10.1007\/s00167-021-06462-6","article-title":"Kinematic alignment of medial UKA is safe: a systematic review","volume":"30","author":"Riviere","year":"2022","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.artd.2026.102147_bib10","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.jor.2024.02.016","article-title":"A retrospective comparison of mechanically vs. kinematically aligned unicompartmental knee arthroplasties","volume":"52","author":"Gulati","year":"2024","journal-title":"J Orthop"},{"key":"10.1016\/j.artd.2026.102147_bib11","doi-asserted-by":"crossref","first-page":"3220","DOI":"10.1007\/s00167-021-06683-9","article-title":"The medial condylar wall is a reliable landmark to kinematically align the femoral component in medial UKA: an in-Silico study","volume":"30","author":"Preston","year":"2022","journal-title":"Knee Surgery Sports Traumatol Arthrosc"},{"key":"10.1016\/j.artd.2026.102147_bib12","doi-asserted-by":"crossref","first-page":"S59","DOI":"10.1016\/j.arth.2024.03.066","article-title":"Femoral coronal malalignment is associated with failure in mobile-bearing medial unicompartmental knee arthroplasty","volume":"39","author":"Lee","year":"2024","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.artd.2026.102147_bib13","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.17554\/j.issn.2311-5106.2020.07.345","article-title":"Traction during total knee arthroplasty leads to a bone-conserving tibial resection: a retrospective comparative study","volume":"7","author":"Brown","year":"2020","journal-title":"Int J Orthop"},{"key":"10.1016\/j.artd.2026.102147_bib14","doi-asserted-by":"crossref","first-page":"183","DOI":"10.4236\/ojo.2021.116018","article-title":"Coronal alignment of three different types of implants in kinematically aligned total knee arthroplasty: a comparative study","volume":"11","author":"Soda","year":"2021","journal-title":"Open J Orthop"},{"key":"10.1016\/j.artd.2026.102147_bib15","doi-asserted-by":"crossref","DOI":"10.2106\/JBJS.ST.23.00059","article-title":"The femur-first technique for Oxford medial unicompartmental knee arthroplasty","volume":"14","author":"Alarcon Perico","year":"2024","journal-title":"JBJS Essent Surg Tech"},{"key":"10.1016\/j.artd.2026.102147_bib16","doi-asserted-by":"crossref","first-page":"S60","DOI":"10.1016\/j.arth.2023.02.012","article-title":"Femur-First technique for Mobile bearing unicompartmental knee arthroplasty results in decreased implant variability and early improvements in function and survivorship","volume":"38","author":"Labott","year":"2023","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.artd.2026.102147_bib17","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1016\/j.knee.2012.04.008","article-title":"The Oxford medial partial knee replacement. The rationale for a femur first technique","volume":"19","author":"Shakespeare","year":"2012","journal-title":"Knee"}],"container-title":["Arthroplasty Today"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352344126001962?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352344126001962?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T06:56:08Z","timestamp":1790232968000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2352344126001962"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":17,"alternative-id":["S2352344126001962"],"URL":"https:\/\/doi.org\/10.1016\/j.artd.2026.102147","relation":{},"ISSN":["2352-3441"],"issn-type":[{"value":"2352-3441","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Femur-First Cut Kinematically Aligned Unicompartmental Knee Arthroplasty: A Seamless Surgical Technique from UKA to TKA","name":"articletitle","label":"Article Title"},{"value":"Arthroplasty Today","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.artd.2026.102147","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author(s). Published by Elsevier Inc. on behalf of American Association of Hip and Knee Surgeons.","name":"copyright","label":"Copyright"}],"article-number":"102147"}}