{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,5,17]],"date-time":"2023-05-17T16:12:15Z","timestamp":1684339935986},"reference-count":39,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2009,4,1]],"date-time":"2009-04-01T00:00:00Z","timestamp":1238544000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Arthroplasty"],"published-print":{"date-parts":[[2009,4]]},"DOI":"10.1016\/j.arth.2007.10.034","type":"journal-article","created":{"date-parts":[[2008,4,9]],"date-time":"2008-04-09T14:00:48Z","timestamp":1207749648000},"page":"391-399","source":"Crossref","is-referenced-by-count":6,"title":["Midterm Survivorship of a Press-Fit, Plasma-Sprayed, Tri-Spike Acetabular Component"],"prefix":"10.1016","volume":"24","author":[{"given":"Mark A.","family":"Klaassen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mario","family":"Mart\u00ednez-Villalobos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William S.","family":"Pietrzak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gerardo P.","family":"Mangino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Delfino Carranza","family":"Guzman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"Suppl 286","key":"10.1016\/j.arth.2007.10.034_bib1","first-page":"1","article-title":"The acetabular component in total hip arthroplasty. Evaluation of different fixation principles","volume":"70","author":"Thanner","year":"1999","journal-title":"Acta Orthop Scand"},{"key":"10.1016\/j.arth.2007.10.034_bib2","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1302\/0301-620X.85B1.12925","article-title":"The relationship between cup design and radiological signs of aseptic loosening in total hip arthroplasty","volume":"85-B","author":"M\u00fcller","year":"2003","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2007.10.034_bib3","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/j.arth.2004.09.025","article-title":"Cementless porous-coated sockets without holes implanted with pure press-fit technique","volume":"20","author":"Spak","year":"2005","journal-title":"J Arthroplasty"},{"issue":"Suppl 1","key":"10.1016\/j.arth.2007.10.034_bib4","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.arth.2004.02.017","article-title":"Are all cementless acetabular components created equal?","volume":"19","author":"Callaghan","year":"2004","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2007.10.034_bib5","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1097\/01.blo.0000096824.67494.aa","article-title":"Results of uncemented cups","volume":"417","author":"Harris","year":"2003","journal-title":"Clin Orthop Relat Res"},{"issue":"Suppl 2","key":"10.1016\/j.arth.2007.10.034_bib6","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.arth.2004.06.016","article-title":"Mid-term results of a polyethylene-free metal-on-metal articulation","volume":"19","author":"Lombardi","year":"2004","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2007.10.034_bib7","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1097\/00003086-199201000-00018","article-title":"Current status of acetabular fixation in primary total hip arthroplasty","volume":"274","author":"Morscher","year":"1992","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2007.10.034_bib8","first-page":"154","article-title":"Optimum acetabular component fixation","volume":"4","author":"Stiehl","year":"1993","journal-title":"Semin Arthroplasty"},{"key":"10.1016\/j.arth.2007.10.034_bib9","doi-asserted-by":"crossref","first-page":"299","DOI":"10.2106\/00004623-199302000-00020","article-title":"The clinical results and basic science of total hip arthroplasty with porous-coated prostheses","volume":"75-A","author":"Callaghan","year":"1993","journal-title":"J Bone Joint Surg Am"},{"issue":"Suppl 2","key":"10.1016\/j.arth.2007.10.034_bib10","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.arth.2004.06.004","article-title":"Long-term porous coated cup survivorship using spikes, screws, and press-fitting for initial fixation","volume":"19","author":"Engh","year":"2004","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2007.10.034_bib11","doi-asserted-by":"crossref","first-page":"1130","DOI":"10.2106\/00004623-199274080-00002","article-title":"The Harris-Galante porous-coated acetabular component with screw fixation","volume":"74-A","author":"Schmalzried","year":"1992","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2007.10.034_bib12","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/0883-5403(92)90052-R","article-title":"Stability of press-fit acetabular cups","volume":"7","author":"Adler","year":"1992","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2007.10.034_bib13","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1054\/arth.2002.34526","article-title":"Load transfer and fixation mode of press-fit acetabular sockets","volume":"17","author":"Widmer","year":"2002","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2007.10.034_bib14","doi-asserted-by":"crossref","first-page":"975","DOI":"10.2106\/00004623-199607000-00001","article-title":"Porous-coated acetabular component with screw fixation. Five to ten-years results","volume":"78-A","author":"Latimer","year":"1996","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2007.10.034_bib15","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/S0883-5403(06)80179-8","article-title":"Mechanical stability of porous-coated acetabular components in total hip arthroplasty","volume":"6","author":"Stiehl","year":"1991","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2007.10.034_bib16","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/S0883-5403(06)80076-8","article-title":"Acetabular micromotion as a measure of initial implant stability in primary hip arthroplasty","volume":"7","author":"Perona","year":"1992","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2007.10.034_bib17","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1046\/j.1525-1594.2001.025008664.x","article-title":"Initial stability of cementless acetabular cup design: experimental investigation on the effect of adding fins to the rim of the cup","volume":"25","author":"Baleani","year":"2001","journal-title":"Artif Organs"},{"key":"10.1016\/j.arth.2007.10.034_bib18","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/0267-6605(94)90110-4","article-title":"Prestresses around the acetabulum generated by screwed cups","volume":"16","author":"Dalstra","year":"1994","journal-title":"Clin Mater"},{"key":"10.1016\/j.arth.2007.10.034_bib19","doi-asserted-by":"crossref","first-page":"501","DOI":"10.2106\/00004623-199072040-00005","article-title":"Acetabular anatomy and transacetabular fixation of screws in total hip arthroplasty","volume":"72-A","author":"Wasielewski","year":"1990","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2007.10.034_bib20","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1007\/s00402-005-0001-9","article-title":"Press fit fixation of cementless cups: how much stability do we need indeed?","volume":"126","author":"Roth","year":"2006","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.arth.2007.10.034_bib21","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/0883-5403(94)90065-5","article-title":"A quantitative in vitro assessment of fit and screw fixation on the stability of a cementless hemispherical acetabular component","volume":"9","author":"Kwong","year":"1994","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2007.10.034_bib22","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1302\/0301-620X.77B3.7744942","article-title":"Micromotion of cementless hemispherical acetabular components. Does press-fit need adjunctive screw fixation?","volume":"77-B","author":"Won","year":"1995","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2007.10.034_bib23","doi-asserted-by":"crossref","first-page":"925","DOI":"10.1016\/S0883-5403(99)90005-0","article-title":"5 year review of second-generation acetabular cup with dome screws","volume":"14","author":"Fisher","year":"1999","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2007.10.034_bib24","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.2106\/00004623-199909000-00010","article-title":"Effect of circumferential plasma-spray porous coating on the rate of femoral osteolysis after total hip arthroplasty","volume":"81-A","author":"Emerson","year":"1999","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2007.10.034_bib25","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1007\/s00264-001-0314-4","article-title":"Press-fit stability of uncemented hemispheric acetabular components: a comparison of three porous coating systems","volume":"26","author":"Markel","year":"2002","journal-title":"Int Orthop"},{"key":"10.1016\/j.arth.2007.10.034_bib26","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1002\/jbm.a.30671","article-title":"Osteoblast response to plasma-spray porous Ti6Al4V coating on substrates of identical alloy","volume":"77A","author":"Saldana","year":"2006","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.arth.2007.10.034_bib27","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/S0883-5403(97)90020-6","article-title":"Integral porous femoral stem: 5- to 8-year follow-up study","volume":"12","author":"Mauerhan","year":"1997","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2007.10.034_bib28","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1007\/s00776-003-0689-8","article-title":"Cementless total hip arthroplasty using porous-coated Biomet acetabular cups (Hexloc and Ringloc types)","volume":"8","author":"Yamamoto","year":"2003","journal-title":"J Orthop Sci"},{"key":"10.1016\/j.arth.2007.10.034_bib29","article-title":"Comparison of polyethylene wear in machined versus molded polyethylene liners in RingLoc acetabular cups","author":"Head","year":"2001"},{"issue":"Suppl","key":"10.1016\/j.arth.2007.10.034_bib30","first-page":"183","article-title":"The new polys: bridges too far?","volume":"84-B","author":"Ries","year":"2003","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2007.10.034_bib31","first-page":"20","article-title":"Radiological demarcation of cemented sockets in total hip replacement","volume":"121","author":"DeLee","year":"1976","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2007.10.034_bib32","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1097\/00003086-199612000-00023","article-title":"Primary cementless hip arthroplasty with a titanium plasma sprayed prosthesis","volume":"333","author":"Hozack","year":"1996","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2007.10.034_bib33","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1302\/0301-620X.87B6.15335","article-title":"Ten-year results of a press-fit, porous-coated acetabular component","volume":"87-B","author":"Grobler","year":"2005","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2007.10.034_bib34","doi-asserted-by":"crossref","first-page":"66","DOI":"10.2106\/00004623-199901000-00010","article-title":"The Harris-Galante porous-coated acetabular component with screw fixation: an average ten-year follow-up study","volume":"81","author":"Clohisy","year":"1999","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2007.10.034_bib35","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1002\/jbm.10203","article-title":"Interaction of oxidation and crosslinking in gamma-irradiated ultrahigh molecular-weight polyethylene","volume":"61","author":"Shen","year":"2002","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.arth.2007.10.034_bib36","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1002\/1097-4636(200108)56:2<168::AID-JBM1081>3.0.CO;2-M","article-title":"Time- and depth-dependent changes in crosslinking and oxidation of shelf-aged polyethylene acetabular liners","volume":"56","author":"Jacob","year":"2001","journal-title":"J Biomed Mater Res"},{"issue":"2 Suppl","key":"10.1016\/j.arth.2007.10.034_bib37","first-page":"s243","article-title":"The influence of sterilization method on wear performance of the low contact stress total knee system","volume":"25","author":"McNulty","year":"2002","journal-title":"Orthopedics"},{"key":"10.1016\/j.arth.2007.10.034_bib38","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1016\/j.arth.2003.10.005","article-title":"The pumping of fluid in cementless cups with holes","volume":"19","author":"Walter","year":"2004","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2007.10.034_bib39","doi-asserted-by":"crossref","first-page":"2323","DOI":"10.2106\/JBJS.E.00223","article-title":"Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty","volume":"87","author":"McCalden","year":"2005","journal-title":"J Bone Joint Surg Am"}],"container-title":["The Journal of Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540307006390?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540307006390?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2023,5,17]],"date-time":"2023-05-17T15:28:44Z","timestamp":1684337324000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0883540307006390"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,4]]},"references-count":39,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2009,4]]}},"alternative-id":["S0883540307006390"],"URL":"https:\/\/doi.org\/10.1016\/j.arth.2007.10.034","relation":{},"ISSN":["0883-5403"],"issn-type":[{"value":"0883-5403","type":"print"}],"subject":[],"published":{"date-parts":[[2009,4]]}}}