{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T10:21:45Z","timestamp":1791973305163,"version":"4.3.4"},"reference-count":16,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2011,9,1]],"date-time":"2011-09-01T00:00:00Z","timestamp":1314835200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Arthroplasty"],"published-print":{"date-parts":[[2011,9]]},"DOI":"10.1016\/j.arth.2011.04.012","type":"journal-article","created":{"date-parts":[[2011,6,19]],"date-time":"2011-06-19T12:20:55Z","timestamp":1308486055000},"page":"19-23","source":"Crossref","is-referenced-by-count":44,"special_numbering":"S","title":["Gender is a Significant Factor for Failure of Metal-on-Metal Total Hip Arthroplasty"],"prefix":"10.1016","volume":"26","author":[{"given":"Michael J.","family":"Latteier","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keith R.","family":"Berend","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"Jr.","given":"Adolph V.","family":"Lombardi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew F.","family":"Ajluni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian E.","family":"Seng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joanne B.","family":"Adams","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.arth.2011.04.012_bb0005","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1097\/01.blo.0000246561.73338.68","article-title":"Larger diameter bearings reduce wear in metal-on-metal hip implants","volume":"456","author":"Affatato","year":"2007","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2011.04.012_bb0010","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1097\/01.blo.0000193809.85587.f8","article-title":"The rationale for metal-on-metal total hip arthroplasty","volume":"441","author":"Cuckler","year":"2005","journal-title":"Clin Orthop Relat Res"},{"issue":"7 Suppl 2","key":"10.1016\/j.arth.2011.04.012_bb0015","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.arth.2004.06.016","article-title":"Mid-term results of a polyethylene-free metal-on-metal articulation","volume":"19","author":"Lombardi","year":"2004","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2011.04.012_bb0020","doi-asserted-by":"crossref","first-page":"2313","DOI":"10.1007\/s11999-010-1419-0","article-title":"Failed metal-on-metal hip arthroplasties: a spectrum of clinical presentations and operative findings","volume":"468","author":"Browne","year":"2010","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2011.04.012_bb0025","doi-asserted-by":"crossref","first-page":"1515","DOI":"10.2106\/JBJS.D.02641","article-title":"Early osteolysis following second-generation metal-on-metal hip replacement","volume":"87","author":"Park","year":"2005","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2011.04.012_bb0030","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1302\/0301-620X.92B1.22226","article-title":"Metal ion release from bearing wear and corrosion with 28 mm and large-diameter metal-on-metal bearing articulations: a follow-up study","volume":"92","author":"Vendittoli","year":"2010","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2011.04.012_bb0035","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/s11999-008-0540-9","article-title":"2008 John Charnley award: metal ion levels after metal-on-metal total hip arthroplasty: a randomized trial","volume":"467","author":"Engh","year":"2009","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2011.04.012_bb0040","doi-asserted-by":"crossref","first-page":"69","DOI":"10.5435\/00124635-200902000-00003","article-title":"Metal-on-metal bearing surfaces","volume":"17","author":"Jacobs","year":"2009","journal-title":"J Am Acad Orthop Surg"},{"key":"10.1016\/j.arth.2011.04.012_bb0045","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1243\/09544119JEIM518","article-title":"Influence of cup orientation on the wear performance of metal-on-metal hip replacements","volume":"223","author":"Angadji","year":"2009","journal-title":"Proc Inst Mech Eng H"},{"key":"10.1016\/j.arth.2011.04.012_bb0050","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1302\/0301-620X.90B10.20533","article-title":"Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement","volume":"90","author":"De Haan","year":"2008","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2011.04.012_bb0055","doi-asserted-by":"crossref","first-page":"2328","DOI":"10.1007\/s11999-010-1383-8","article-title":"Reduced articular surface of one-piece cups: a cause of runaway wear and early failure","volume":"468","author":"Griffin","year":"2010","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2011.04.012_bb0060","first-page":"189","article-title":"The problem with large diameter metal-on-metal acetabular cup inclination","volume":"67","author":"Jeffers","year":"2009","journal-title":"Bull NYU Hosp Jt Dis"},{"key":"10.1016\/j.arth.2011.04.012_bb0065","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1302\/0301-620X.91B8.21701","article-title":"Early clinical failure of the Birmingham metal-on-metal hip resurfacing is associated with metallosis and soft-tissue necrosis","volume":"91","author":"Ollivere","year":"2009","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2011.04.012_bb0070","doi-asserted-by":"crossref","first-page":"847","DOI":"10.1302\/0301-620X.90B7.20213","article-title":"Pseudotumours associated with metal-on-metal hip resurfacings","volume":"90","author":"Pandit","year":"2008","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2011.04.012_bb0075","doi-asserted-by":"crossref","first-page":"1566","DOI":"10.1302\/0301-620X.91B12.22287","article-title":"Risk factors for inflammatory pseudotumour formation following hip resurfacing","volume":"91","author":"Glyn-Jones","year":"2009","journal-title":"J Bone Joint Surg Br"},{"issue":"Suppl 3","key":"10.1016\/j.arth.2011.04.012_bb0080","doi-asserted-by":"crossref","first-page":"111","DOI":"10.2106\/JBJS.H.00485","article-title":"Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position","volume":"90","author":"Williams","year":"2008","journal-title":"J Bone Joint Surg Am"}],"container-title":["The Journal of Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540311001719?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540311001719?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,12,2]],"date-time":"2018-12-02T01:20:20Z","timestamp":1543713620000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0883540311001719"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,9]]},"references-count":16,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2011,9]]}},"alternative-id":["S0883540311001719"],"URL":"https:\/\/doi.org\/10.1016\/j.arth.2011.04.012","relation":{},"ISSN":["0883-5403"],"issn-type":[{"value":"0883-5403","type":"print"}],"subject":[],"published":{"date-parts":[[2011,9]]}}}