{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T12:06:48Z","timestamp":1781525208896,"version":"3.54.1"},"reference-count":33,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2011,9,1]],"date-time":"2011-09-01T00:00:00Z","timestamp":1314835200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Arthroplasty"],"published-print":{"date-parts":[[2011,9]]},"DOI":"10.1016\/j.arth.2011.04.032","type":"journal-article","created":{"date-parts":[[2011,6,23]],"date-time":"2011-06-23T22:14:24Z","timestamp":1308867264000},"page":"72-77","source":"Crossref","is-referenced-by-count":51,"special_numbering":"S","title":["Comparison of Surgical Outcomes and Implant Wear Between Ceramic-Ceramic and Ceramic-Polyethylene Articulations in Total Hip Arthroplasty"],"prefix":"10.1016","volume":"26","author":[{"given":"Derek F.","family":"Amanatullah","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joshua","family":"Landa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric J.","family":"Strauss","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan P.","family":"Garino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sunny H.","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul E.","family":"Di Cesare","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.arth.2011.04.032_bb0005","doi-asserted-by":"crossref","first-page":"113","DOI":"10.3109\/17453679408993734","article-title":"Osteolysis and particle disease in hip replacement. A review","volume":"65","author":"Harris","year":"1994","journal-title":"Acta Orthop Scand"},{"key":"10.1016\/j.arth.2011.04.032_bb0010","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1054\/arth.2002.33664","article-title":"A literature review of the association between wear rate and osteolysis in total hip arthroplasty","volume":"17","author":"Dumbleton","year":"2002","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2011.04.032_bb0015","doi-asserted-by":"crossref","first-page":"530","DOI":"10.2106\/JBJS.D.01753","article-title":"Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study","volume":"87","author":"Yoo","year":"2005","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2011.04.032_bb0020","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1007\/s00776-005-0911-y","article-title":"Effect of alumina femoral head on clinical results in cemented total hip arthroplasty: old versus current alumina","volume":"10","author":"Kawanabe","year":"2005","journal-title":"J Orthop Sci"},{"key":"10.1016\/j.arth.2011.04.032_bb0025","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1097\/01.blo.0000162995.50971.39","article-title":"Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study","volume":"436","author":"D'Antonio","year":"2005","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2011.04.032_bb0030","doi-asserted-by":"crossref","first-page":"39","DOI":"10.3928\/0147-7447-20030101-13","article-title":"Alumina ceramic bearings for total hip arthroplasty","volume":"26","author":"D'Antonio","year":"2003","journal-title":"Orthopedics"},{"key":"10.1016\/j.arth.2011.04.032_bb0035","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1097\/00003086-200212000-00019","article-title":"Ceramic-on-ceramic bearings in total hip arthroplasty","volume":"405","author":"Bierbaum","year":"2002","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2011.04.032_bb0040","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1054\/arth.2002.32183","article-title":"New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty","volume":"17","author":"D'Antonio","year":"2002","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2011.04.032_bb0045","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1097\/00003086-199209000-00009","article-title":"Ten- to 14-year results of a ceramic hip prosthesis","volume":"282","author":"Winter","year":"1992","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2011.04.032_bb0050","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1097\/00003086-200108000-00017","article-title":"Debris from failed ceramic-on-ceramic and ceramic-on-polyethylene hip prostheses","volume":"389","author":"Mochida","year":"2001","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2011.04.032_bb0055","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1016\/j.arth.2009.01.013","article-title":"Prospective randomized trial comparing alumina ceramic-on-ceramic with ceramic-on-conventional polyethylene bearings in total hip arthroplasty","volume":"25","author":"Lewis","year":"2010","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2011.04.032_bb0060","doi-asserted-by":"crossref","first-page":"518","DOI":"10.2106\/00004623-199072040-00008","article-title":"Effect of femoral head size on wear of the polyethylene acetabular component","volume":"72","author":"Livermore","year":"1990","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2011.04.032_bb0065","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1243\/0954411001535381","article-title":"Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements","volume":"214","author":"Clarke","year":"2000","journal-title":"Proc Inst Mech Eng [H]"},{"key":"10.1016\/j.arth.2011.04.032_bb0070","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1097\/00003086-199209000-00005","article-title":"On the material and the tribology of alumina-alumina couplings for hip joint prostheses","volume":"282","author":"Walter","year":"1992","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2011.04.032_bb0075","first-page":"279","article-title":"A study of the mechanical properties of alumina-on-alumina total hip prosthesis (author's translation)","volume":"67","author":"Boutin","year":"1981","journal-title":"Rev Chir Orthop Reparatrice Appar Mot"},{"key":"10.1016\/j.arth.2011.04.032_bb0080","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1016\/S0883-5403(99)90025-6","article-title":"Wear rates of ceramic-on-ceramic bearing surfaces in total hip implants: a 12-year follow-up study","volume":"14","author":"Jazrawi","year":"1999","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2011.04.032_bb0085","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1097\/00003086-199209000-00011","article-title":"Comparison of alumina-polyethylene and metal-polyethylene in clinical trials","volume":"282","author":"Zichner","year":"1992","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2011.04.032_bb0090","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1302\/0301-620X.85B5.13923","article-title":"Effect of alumina femoral heads on polyethylene wear in cemented total hip arthroplasty. Old versus current alumina","volume":"85","author":"Tanaka","year":"2003","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2011.04.032_bb0095","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1302\/0301-620X.85B4.13397","article-title":"Zirconia and alumina ceramics in comparison with stainless-steel heads. Polyethylene wear after a minimum ten-year follow-up","volume":"85","author":"Hernigou","year":"2003","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2011.04.032_bb0100","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1302\/0301-620X.78B2.0780280","article-title":"Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups","volume":"78","author":"Wroblewski","year":"1996","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2011.04.032_bb0105","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1097\/00003086-200010000-00006","article-title":"Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear","volume":"379","author":"Clarke","year":"2000","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2011.04.032_bb0110","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1002\/jbm.820250703","article-title":"Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy","volume":"25","author":"Kumar","year":"1991","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.arth.2011.04.032_bb0115","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1097\/01.blo.0000149996.91974.83","article-title":"Ceramics in total hip replacement","volume":"430","author":"Hannouche","year":"2005","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2011.04.032_bb0120","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1097\/00003086-200010000-00014","article-title":"Wear of alumina-on-alumina total hip arthroplasties at a mean 11-year followup","volume":"379","author":"Prudhommeaux","year":"2000","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2011.04.032_bb0125","unstructured":"O'Toole GC, Walter WL, Zicat BA, Walter WK. Squeaking in ceramic-on-ceramic hips; incidence, causes and solutions. Paper presented at: American Association of Orthopaedic Surgeons. 2006; San Diego, CA."},{"issue":"Suppl 4","key":"10.1016\/j.arth.2011.04.032_bb0130","doi-asserted-by":"crossref","first-page":"55","DOI":"10.2106\/JBJS.F.00587","article-title":"Early diagnosis of ceramic liner fracture. Guidelines based on a twelve-year clinical experience","volume":"88","author":"Toni","year":"2006","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2011.04.032_bb0135","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1163\/156856299X00162","article-title":"Wear debris and cytokine production in the interface membrane of loosened prostheses","volume":"10","author":"Stea","year":"1999","journal-title":"J Biomater Sci Polym Ed"},{"key":"10.1016\/j.arth.2011.04.032_bb0140","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/0883-5403(94)90059-0","article-title":"Severe polyethylene wear in total hip arthroplasty. Observations from retrieved AML PLUS hip implants with an ACS polyethylene liner","volume":"9","author":"Bono","year":"1994","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2011.04.032_bb0145","doi-asserted-by":"crossref","first-page":"780","DOI":"10.2106\/JBJS.E.00618","article-title":"Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing","volume":"88","author":"Park","year":"2006","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2011.04.032_bb0150","doi-asserted-by":"crossref","DOI":"10.1007\/3-7985-1540-9_25","article-title":"Ceramic component fracture: trends and recommendations with modern components based on improving reported methods","author":"Garino","year":"2005"},{"key":"10.1016\/j.arth.2011.04.032_bb0155","first-page":"369","article-title":"Ceramic-ceramic coupling. Total hip arthroplasty in young patients","volume":"88","author":"Pignatti","year":"2003","journal-title":"Chir Organi Mov"},{"key":"10.1016\/j.arth.2011.04.032_bb0160","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1097\/BLO.0b013e3180303e87","article-title":"Ceramic liner fracture after cementless alumina-on-alumina total hip arthroplasty","volume":"458","author":"Ha","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2011.04.032_bb0165","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1097\/01.blo.0000150132.11142.d2","article-title":"Concerns about ceramics in THA","volume":"429","author":"Barrack","year":"2004","journal-title":"Clin Orthop Relat Res"}],"container-title":["The Journal of Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540311002166?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540311002166?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2023,6,7]],"date-time":"2023-06-07T13:04:15Z","timestamp":1686143055000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0883540311002166"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,9]]},"references-count":33,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2011,9]]}},"alternative-id":["S0883540311002166"],"URL":"https:\/\/doi.org\/10.1016\/j.arth.2011.04.032","relation":{},"ISSN":["0883-5403"],"issn-type":[{"value":"0883-5403","type":"print"}],"subject":[],"published":{"date-parts":[[2011,9]]}}}