{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,21]],"date-time":"2025-08-21T17:46:28Z","timestamp":1755798388193},"reference-count":43,"publisher":"Elsevier BV","issue":"8","license":[{"start":{"date-parts":[[2014,8,1]],"date-time":"2014-08-01T00:00:00Z","timestamp":1406851200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["patient-research.elsevier.com","arthroplastyjournal.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Arthroplasty"],"published-print":{"date-parts":[[2014,8]]},"DOI":"10.1016\/j.arth.2014.03.030","type":"journal-article","created":{"date-parts":[[2014,3,28]],"date-time":"2014-03-28T21:32:36Z","timestamp":1396042356000},"page":"1647-1652","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"title":["MRI Findings Following Metal on Metal Hip Arthroplasty and Their Relationship With Metal Ion Levels and Acetabular Inclination Angles"],"prefix":"10.1016","volume":"29","author":[{"given":"Ciara M.","family":"Fox","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karen M.","family":"Bergin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gabrielle E.","family":"Kelly","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gerry F.","family":"McCoy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anthony G.","family":"Ryan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John F.","family":"Quinlan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.arth.2014.03.030_bb0005","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1302\/0301-620X.81B1.9047","article-title":"Analysis of 118second-generation metal-on-metal retrieved hip implants","volume":"81","author":"Sieber","year":"1999","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2014.03.030_bb0010","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1097\/01.blo.0000193809.85587.f8","article-title":"The rationale for metal-on-metal total hip arthroplasty","volume":"441","author":"Cuckler","year":"2005","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2014.03.030_bb0015","doi-asserted-by":"crossref","first-page":"1836","DOI":"10.2106\/00004623-200210000-00015","article-title":"In vivo comparison of hip separation after metal-on-metal or metal-on-polyethylene total hip arthroplasty","volume":"84-A","author":"Komistek","year":"2002","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2014.03.030_bb0020","doi-asserted-by":"crossref","first-page":"2287","DOI":"10.2106\/JBJS.J.01727","article-title":"Five-year results of the ASR XL Acetabular System and the ASR Hip Resurfacing System: an analysis from the Australian Orthopaedic Association National Joint Replacement Registry","volume":"93","author":"de Steiger","year":"2011","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2014.03.030_bb0025","doi-asserted-by":"crossref","first-page":"207","DOI":"10.3109\/17453674.2012.693016","article-title":"Hip resurfacing arthroplasty: short-term survivorship of 4,401 hips from the Finnish Arthroplasty Register","volume":"83","author":"Seppanen","year":"2012","journal-title":"Acta Orthop"},{"key":"10.1016\/j.arth.2014.03.030_bb0030","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.arth.2011.03.027","article-title":"Early failure of articular surface replacement XL total hip arthroplasty","volume":"26","author":"Steele","year":"2011","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2014.03.030_bb0035","doi-asserted-by":"crossref","first-page":"d2905","DOI":"10.1136\/bmj.d2905","article-title":"Out of joint: the story of the ASR","volume":"342","author":"Cohen","year":"2011","journal-title":"BMJ"},{"key":"10.1016\/j.arth.2014.03.030_bb0040","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1302\/0301-620X.91B10.22308","article-title":"Blood metal ion concentrations after hip resurfacing arthroplasty: a comparative study of articular surface replacement and Birmingham Hip Resurfacing arthroplasties","volume":"91","author":"Langton","year":"2009","journal-title":"J Bone Joint Surg"},{"issue":"Suppl. 1","key":"10.1016\/j.arth.2014.03.030_bb0045","doi-asserted-by":"crossref","first-page":"S68","DOI":"10.5435\/00124635-200800001-00014","article-title":"Are there biological markers of wear?","volume":"16","author":"Bauer","year":"2008","journal-title":"J Am Acad Orthop Surg"},{"key":"10.1016\/j.arth.2014.03.030_bb0050","doi-asserted-by":"crossref","first-page":"1143","DOI":"10.1302\/0301-620X.90B9.20785","article-title":"The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip","volume":"90","author":"Langton","year":"2008","journal-title":"J Bone Joint Surg Br"},{"issue":"Suppl. 4","key":"10.1016\/j.arth.2014.03.030_bb0055","doi-asserted-by":"crossref","first-page":"202","DOI":"10.2106\/JBJS.H.00672","article-title":"Metal ion measurement as a diagnostic tool to identify problems with metal-on-metal hip resurfacing","volume":"90","author":"De Smet","year":"2008","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2014.03.030_bb0060","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1302\/0301-620X.93B3.25545","article-title":"The relationship between the angle of version and rate of wear of retrieved metal-on-metal resurfacings: a prospective, CT-based study","volume":"93","author":"Hart","year":"2011","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2014.03.030_bb0065","doi-asserted-by":"crossref","first-page":"1158","DOI":"10.1302\/0301-620X.90B9.19891","article-title":"Revision of metal-on-metal resurfacing arthroplasty of the hip: the influence of malpositioning of the components","volume":"90","author":"De Haan","year":"2008","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2014.03.030_bb0070","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1302\/0301-620X.90B10.20533","article-title":"Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement","volume":"90","author":"De Haan","year":"2008","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2014.03.030_bb0075","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1097\/01.blo.0000238777.34939.82","article-title":"The John Charnley Award: a study of implant failure in metal-on-metal surface arthroplasties","volume":"453","author":"Campbell","year":"2006","journal-title":"Clin Orthop Relat Res"},{"issue":"Suppl. 1","key":"10.1016\/j.arth.2014.03.030_bb0080","first-page":"S20","article-title":"The effect of operative factors on outlier ion levels in patients with metal-on-metal hip arthroplasties","volume":"69","author":"Bernstein","year":"2011","journal-title":"Bull NYU Hosp Jt Dis"},{"key":"10.1016\/j.arth.2014.03.030_bb0085","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.arth.2013.04.022","article-title":"The effect of acetabular inclincation on metal ion levels following metal-on-metal arthroplasty","volume":"29","author":"Emmanuel","year":"2014","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2014.03.030_bb0090","doi-asserted-by":"crossref","first-page":"107","DOI":"10.5301\/HIP.2012.9034","article-title":"The effect of obesity on blood metal ion levels after hip resurfacing and metal-on-metal total hip replacement","volume":"22","author":"Sawalha","year":"2012","journal-title":"Hip Int"},{"key":"10.1016\/j.arth.2014.03.030_bb0095","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1243\/09544119JEIM270","article-title":"Can cobalt levels estimate in-vivo wear of metal-on-metal bearings used in hip arthroplasty?","volume":"221","author":"Khan","year":"2007","journal-title":"Proc Inst Mech Eng H"},{"key":"10.1016\/j.arth.2014.03.030_bb0100","doi-asserted-by":"crossref","first-page":"1308","DOI":"10.1302\/0301-620X.93B10.26249","article-title":"Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement","volume":"93","author":"Hart","year":"2011","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.arth.2014.03.030_bb0115","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1016\/j.ocl.2006.04.001","article-title":"Metal artifact reduction in musculoskeletal magnetic resonance imaging","volume":"37","author":"Harris","year":"2006","journal-title":"Orthop Clin North Am"},{"key":"10.1016\/j.arth.2014.03.030_bb0120","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.crad.2007.07.012","article-title":"MRI of early symptomatic metal-on-metal total hip arthroplasty: a retrospective review of radiological findings in 20 hips","volume":"63","author":"Toms","year":"2008","journal-title":"Clin Radiol"},{"key":"10.1016\/j.arth.2014.03.030_bb0125","doi-asserted-by":"crossref","first-page":"847","DOI":"10.1302\/0301-620X.90B7.20213","article-title":"Pseudotumours associated with metal-on-metal hip resurfacings","volume":"90","author":"Pandit","year":"2008","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2014.03.030_bb0130","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1302\/0301-620X.92B1.22770","article-title":"Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear","volume":"92","author":"Langton","year":"2010","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2014.03.030_bb0135","doi-asserted-by":"crossref","first-page":"1045","DOI":"10.1302\/0301-620X.94B8.27626","article-title":"The sensitivity, specificity and predictive values of raised plasma metal ion levels in the diagnosis of adverse reaction to metal debris in symptomatic patients with a metal-on-metal arthroplasty of the hip","volume":"94","author":"Malek","year":"2012","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.arth.2014.03.030_bb0150","first-page":"78","article-title":"Fatty muscle degeneration in cuff ruptures. Pre- and postoperative evaluation by CT scan","author":"Goutallier","year":"1994","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2014.03.030_bb0155","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1148\/radiol.2353040403","article-title":"Abductor tendons and muscles assessed at MR imaging after total hip arthroplasty in asymptomatic and symptomatic patients","volume":"235","author":"Pfirrmann","year":"2005","journal-title":"Radiology"},{"key":"10.1016\/j.arth.2014.03.030_bb0160","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1016\/j.arth.2011.06.004","article-title":"Magnetic resonance imaging features of preserved vs divided and repaired piriformis during total hip arthroplasty: a randomized controlled trial","volume":"27","author":"Khan","year":"2012","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2014.03.030_bb0165","doi-asserted-by":"crossref","first-page":"678","DOI":"10.2106\/JBJS.J.01447","article-title":"Which factors determine the wear rate of large-diameter metal-on-metal hip replacements? Multivariate analysis of two hundred and seventy-six components","volume":"95","author":"Hart","year":"2013","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2014.03.030_bb0170","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1302\/0301-620X.88B3.16748","article-title":"A benign psoas mass following metal-on-metal resurfacing of the hip","volume":"88","author":"Boardman","year":"2006","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2014.03.030_bb0175","doi-asserted-by":"crossref","first-page":"738","DOI":"10.1302\/0301-620X.91B6.21682","article-title":"The painful metal-on-metal hip resurfacing","volume":"91","author":"Hart","year":"2009","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2014.03.030_bb0180","doi-asserted-by":"crossref","first-page":"301","DOI":"10.3109\/17453674.2011.579518","article-title":"Silent soft tissue pathology is common with a modern metal-on-metal hip arthroplasty","volume":"82","author":"Wynn-Jones","year":"2011","journal-title":"Acta Orthop"},{"key":"10.1016\/j.arth.2014.03.030_bb0185","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/j.arth.2010.05.030","article-title":"\"Asymptomatic\" pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study","volume":"26","author":"Kwon","year":"2011","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2014.03.030_bb0190","doi-asserted-by":"crossref","first-page":"2015","DOI":"10.2106\/JBJS.L.01481","article-title":"Relationship of plasma metal ions and clinical and imaging findings in patients with ASR XL metal-on-metal total hip replacements","volume":"95","author":"Chang","year":"2013","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2014.03.030_bb0195","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1002\/jmri.21124","article-title":"Magnetic resonance imaging of the hip","volume":"27","author":"Hong","year":"2008","journal-title":"J Magn Reson Imaging"},{"key":"10.1016\/j.arth.2014.03.030_bb0200","doi-asserted-by":"crossref","first-page":"1807","DOI":"10.1007\/s00264-012-1570-1","article-title":"Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplasty","volume":"36","author":"Bernstein","year":"2012","journal-title":"Int Orthop"},{"key":"10.1016\/j.arth.2014.03.030_bb0205","first-page":"777","article-title":"Metal ion levels decrease after revision for metallosis arising from large-diameter metal-on-metal hip arthroplasty","volume":"77","author":"Ebreo","year":"2011","journal-title":"Acta Orthop Belg"},{"key":"10.1016\/j.arth.2014.03.030_bb0210","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1302\/0301-620X.94B2.27247","article-title":"Mixing and matching causing taper wear: corrosion associated with pseudotumour formation","volume":"94","author":"Chana","year":"2012","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.arth.2014.03.030_bb0215","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1302\/0301-620X.94B7.29122","article-title":"Corrosion at the neck-stem junction as a cause of metal ion release and pseudotumour formation","volume":"94","author":"Gill","year":"2012","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.arth.2014.03.030_bb0220","doi-asserted-by":"crossref","first-page":"1427","DOI":"10.1302\/0301-620X.93B10.27645","article-title":"Adverse reaction to metal release from a modular metal-on-polyethylene hip prosthesis","volume":"93","author":"Lindgren","year":"2011","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.arth.2014.03.030_bb0225","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.2106\/JBJS.K.01352","article-title":"Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty","volume":"94","author":"Cooper","year":"2012","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2014.03.030_bb0230","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.arth.2012.05.029","article-title":"Metal ion levels not sufficient as a screening measure for adverse reactions in metal-on-metal hip arthroplasties","volume":"28","author":"Macnair","year":"2012","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2014.03.030_bb0235","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1302\/0301-620X.91B8.22562","article-title":"Hip resurfacings revised for inflammatory pseudotumour have a poor outcome","volume":"91","author":"Grammatopolous","year":"2009","journal-title":"J Bone Joint Surg Br"}],"container-title":["The Journal of Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540314002186?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540314002186?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,10,5]],"date-time":"2018-10-05T04:20:46Z","timestamp":1538713246000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0883540314002186"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,8]]},"references-count":43,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2014,8]]}},"alternative-id":["S0883540314002186"],"URL":"https:\/\/doi.org\/10.1016\/j.arth.2014.03.030","relation":{},"ISSN":["0883-5403"],"issn-type":[{"value":"0883-5403","type":"print"}],"subject":[],"published":{"date-parts":[[2014,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"MRI Findings Following Metal on Metal Hip Arthroplasty and Their Relationship With Metal Ion Levels and Acetabular Inclination Angles","name":"articletitle","label":"Article Title"},{"value":"The Journal of Arthroplasty","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arth.2014.03.030","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}