{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T02:46:59Z","timestamp":1792810019900,"version":"4.5.0"},"reference-count":43,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2014,10,1]],"date-time":"2014-10-01T00:00:00Z","timestamp":1412121600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["arthroplastyjournal.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Arthroplasty"],"published-print":{"date-parts":[[2014,10]]},"DOI":"10.1016\/j.arth.2014.05.008","type":"journal-article","created":{"date-parts":[[2014,5,15]],"date-time":"2014-05-15T16:37:43Z","timestamp":1400171863000},"page":"1961-1969","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":35,"title":["Fixation and Wear With a Contemporary Acetabular Component and Cross-Linked Polyethylene at Minimum 10-Year Follow-Up"],"prefix":"10.1016","volume":"29","author":[{"given":"Nicholas A.","family":"Bedard","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John J.","family":"Callaghan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael D.","family":"Stefl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tyler J.","family":"Willman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steve S.","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Devon D.","family":"Goetz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"11","key":"10.1016\/j.arth.2014.05.008_bb0005","doi-asserted-by":"crossref","first-page":"2617","DOI":"10.2106\/JBJS.H.01201","article-title":"Survivorship of a Charnley total hip arthroplasty. A concise follow-up, at a minimum of thirty-five years, of previous reports","volume":"91","author":"Callaghan","year":"2009","journal-title":"J Bone Joint Surg Am"},{"issue":"9","key":"10.1016\/j.arth.2014.05.008_bb0020","doi-asserted-by":"crossref","first-page":"2290","DOI":"10.1007\/s11999-009-0831-9","article-title":"Second-generation extensively porous-coated THA stems at minimum 10-year followup","volume":"467","author":"Hennessy","year":"2009","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2014.05.008_bb0030","doi-asserted-by":"crossref","first-page":"2153","DOI":"10.2106\/JBJS.L.00011","article-title":"Cementless total hip arthroplasty in patients fifty years of age or younger: a minimum ten-year follow-up","volume":"94","author":"Takenaga","year":"2012","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"10.1016\/j.arth.2014.05.008_bb0035","doi-asserted-by":"crossref","first-page":"257","DOI":"10.2106\/00004623-200402000-00007","article-title":"Cementless acetabular fixation at fifteen years. A comparison with the same surgeon's results following acetabular fixation with cement","volume":"86-A","author":"Gaffey","year":"2004","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"10.1016\/j.arth.2014.05.008_bb0055","doi-asserted-by":"crossref","first-page":"1130","DOI":"10.2106\/JBJS.H.00168","article-title":"Primary total hip arthroplasty with a porous-coated acetabular component. A concise follow-up, at a minimum of twenty years, of previous reports","volume":"91","author":"Della Valle","year":"2009","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"10.1016\/j.arth.2014.05.008_bb0075","doi-asserted-by":"crossref","first-page":"234","DOI":"10.2106\/JBJS.K.00237","article-title":"Primary cementless acetabular fixation at a minimum of twenty years of follow-up: a concise update of a previous report","volume":"94","author":"Stefl","year":"2012","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2014.05.008_bb0080","doi-asserted-by":"crossref","first-page":"161","DOI":"10.2106\/00004623-199072020-00002","article-title":"Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results","volume":"72","author":"Johnston","year":"1990","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2014.05.008_bb0085","first-page":"2413","article-title":"Validation study of computerized version of the Western Ontario and McMaster Universities VA3.0 Osteoarthritis Index","volume":"24","author":"Bellamy","year":"1997","journal-title":"J Rheumatol"},{"key":"10.1016\/j.arth.2014.05.008_bb0090","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1097\/00003086-198509000-00007","article-title":"Rating Systems in the Evaluation of Knee Ligament Injuries","volume":"198","author":"Tegner","year":"1985","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2014.05.008_bb0095","doi-asserted-by":"crossref","first-page":"228","DOI":"10.2106\/00004623-198466020-00010","article-title":"Treatment of primary osteoarthritis of the hip. A comparison of total joint and surface replacement arthroplasty","volume":"66","author":"Amstutz","year":"1984","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2014.05.008_bb0100","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/S0883-5403(89)80020-8","article-title":"Evaluation of cementless acetabular component migration. An experimental study","volume":"4","author":"Massin","year":"1989","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2014.05.008_bb0105","first-page":"20","article-title":"Radiological demarcation of cemented sockets in total hip replacement","volume":"121","author":"DeLee","year":"1976","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2014.05.008_bb0110","first-page":"17","article-title":"\u2018Modes of failure\u2019 of cemented stem-type femoral components: a radiographic analysis of loosening","volume":"141","author":"Gruen","year":"1979","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2014.05.008_bb0115","doi-asserted-by":"crossref","first-page":"1064","DOI":"10.2106\/00004623-198668070-00014","article-title":"Loosening of the femoral component after use of the medullary-plug cementing technique. Follow-up note with a minimum five-year follow-up","volume":"68","author":"Harris","year":"1986","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2014.05.008_bb0120","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1097\/00003086-199008000-00022","article-title":"Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components","volume":"257","author":"Engh","year":"1990","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2014.05.008_bb0125","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1302\/0301-620X.62B4.7430222","article-title":"Subsidence of the femoral prosthesis in total hip replacement in relation to the design of the stem","volume":"62","author":"Louden","year":"1980","journal-title":"J Bone Joint Surg (Br)"},{"key":"10.1016\/j.arth.2014.05.008_bb0130","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1002\/jor.1100170512","article-title":"Step activity monitor (SAM): Increased accuracy in quantifying ambulatory activity","volume":"17","author":"Shepherd","year":"1999","journal-title":"J Orthop Res"},{"key":"10.1016\/j.arth.2014.05.008_bb0135","doi-asserted-by":"crossref","first-page":"690","DOI":"10.2106\/00004623-199705000-00008","article-title":"Digital edge-detection measurement of polyethylene wear after total hip arthroplasty","volume":"79","author":"Shaver","year":"1997","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2014.05.008_bb0140","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1302\/0301-620X.75B2.8444946","article-title":"In vivo wear of polyethylene acetabular components","volume":"75","author":"Kabo","year":"1993","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2014.05.008_bb0145","doi-asserted-by":"crossref","first-page":"821","DOI":"10.2106\/00004623-199906000-00009","article-title":"Analysis of temporal wear patterns of porous-coated acetabular components: distinguishing between true wear and so-called bedding-in","volume":"81","author":"Sychterz","year":"1999","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2014.05.008_bb0150","doi-asserted-by":"crossref","first-page":"961","DOI":"10.2106\/00004623-199307000-00002","article-title":"The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. The results of one surgeon","volume":"75","author":"Schulte","year":"1993","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2014.05.008_bb0155","first-page":"66","article-title":"Nonparametric estimation from incomplete observations","volume":"81","author":"Kaplan","year":"1958","journal-title":"J Am Stat Assoc"},{"issue":"2","key":"10.1016\/j.arth.2014.05.008_bb0160","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1007\/s11999-012-2604-0","article-title":"Multicenter Study Group, Malchau H. The 2012 John Charnley Award: Clinical Multicenter Studies of the Wear Performance of Highly Crosslinked Remelted Polyethylene in THA","volume":"471","author":"Bragdon","year":"2013","journal-title":"Clin Orthop Relat Res"},{"issue":"8","key":"10.1016\/j.arth.2014.05.008_bb0165","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.arth.2012.03.048","article-title":"A Prospective, Randomized Study of Cross-Linked and Non-Cross-Linked Polyethylene for Total Hip Arthroplasty at 10-Year Follow-Up","volume":"27","author":"Engh","year":"2012","journal-title":"J Arthroplasty"},{"issue":"7","key":"10.1016\/j.arth.2014.05.008_bb0170","doi-asserted-by":"crossref","first-page":"1014","DOI":"10.1016\/j.arth.2011.03.015","article-title":"Midterm Results of Primary Total Hip Arthroplasty Using Highly Cross-Linked Polyethylene: Minimum 7-Year Follow-Up Study","volume":"26","author":"Lee","year":"2011","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2014.05.008_bb0175","doi-asserted-by":"crossref","first-page":"716","DOI":"10.2106\/JBJS.J.00287","article-title":"The Seven-Year Wear of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty: A Double-Blind, Randomized Controlled Trial Using Radiosterometric Analysis","volume":"93","author":"Thomas","year":"2001","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2014.05.008_bb0180","first-page":"825","article-title":"Continued Improved Wear with an Annealed Highly Cross-linked Polyethylene","volume":"269","author":"Capello","year":"2001","journal-title":"Clin Orthop Relat Res"},{"issue":"2","key":"10.1016\/j.arth.2014.05.008_bb0185","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/j.arth.2010.03.010","article-title":"Cementless Total Hip Arthroplasty With Alumina-on-Highly Cross-Linked Polyethylene Bearing in Young Patients With Femoral Head Osteonecrosis","volume":"26","author":"Kim","year":"2001","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2014.05.008_bb0190","doi-asserted-by":"crossref","first-page":"979","DOI":"10.1007\/s11999-008-0628-2","article-title":"Cross-linked Compared with Historical Polyethylene in THA: An 8-year Clinical Study","volume":"467","author":"Geerdink","year":"2009","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2014.05.008_bb0195","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1302\/0301-620X.95B3.29456","article-title":"New polyethylenes in total hip replacement: a ten- to 12-year follow-up study","volume":"95-B","author":"Garcia-Rey","year":"2013","journal-title":"Bone Joint J"},{"issue":"5","key":"10.1016\/j.arth.2014.05.008_bb0200","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1016\/j.arth.2012.12.005","article-title":"Total Hip Arthroplasty Using Highly Cross-linked Polyethylene in Patients Younger Than 50 Years With Minimum 10-Year Follow-Up","volume":"28","author":"Babovic","year":"2013","journal-title":"J Arthroplasty"},{"issue":"9","key":"10.1016\/j.arth.2014.05.008_bb0205","doi-asserted-by":"crossref","first-page":"1654","DOI":"10.1016\/j.arth.2012.12.020","article-title":"Wear Comparison Between Conventional and Highly Cross-Linked Polyethylene Against a Zirconia Head: A Concise Follow-Up, at an Average 10 Years, of a Previous Report","volume":"28","author":"Fuki","year":"2013","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2014.05.008_bb0210","doi-asserted-by":"crossref","first-page":"2131","DOI":"10.1007\/s00264-013-2036-9","article-title":"A randomized prospective evaluation of ceramic-on-ceramic and ceramic-on -highly cross-linked polyethylene bearings in the same patients with primary cementless total hip arthroplasty","volume":"37","author":"Kim","year":"2012","journal-title":"Int Orthop"},{"key":"10.1016\/j.arth.2014.05.008_bb0215","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.2106\/JBJS.L.01211","article-title":"Polyethylene Wear and Osteolysis After Cementless Total Hip Arthroplasty with Alumina-on Highly Cross-Linked Polyethylene Bearing in Patients Younger Than Thirty Years of Age","volume":"95","author":"Kim","year":"2013","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2014.05.008_bb0220","doi-asserted-by":"crossref","first-page":"1731","DOI":"10.1007\/s00402-011-1360-z","article-title":"Eight-year wear analysis in Longevity highly cross-linked polyethylene liners comparing 26- and 32-mm heads","volume":"131","author":"Nakahara","year":"2011","journal-title":"Arch Orthop Trauma Surg"},{"issue":"3","key":"10.1016\/j.arth.2014.05.008_bb0225","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1016\/j.arth.2013.07.034","article-title":"10-Year Follow-Up Wear Analysis of First-Generation Highly Crosslinked Polyethylene in Primary Total Hip Arthroplasty","volume":"29","author":"Snir","year":"2014","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2014.05.008_bb0230","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1007\/s00776-013-0456-4","article-title":"Results at a minimum of 10years of follow-up for AM and PerRix HA-coated cementless total hip arthroplasty: impact of cross-linked polyethylene on implant longevity","volume":"18","author":"Nakashima","year":"2013","journal-title":"J Orthop Sci"},{"key":"10.1016\/j.arth.2014.05.008_bb0235","doi-asserted-by":"crossref","first-page":"3083","DOI":"10.1007\/s11999-012-2400-x","article-title":"Highly Crosslinked Polyethylene Does Not Reduce Aseptic Loosening in Cemented THA 10-year Findings of a Randomized Study","volume":"470","author":"Johanson","year":"2012","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2014.05.008_bb0240","doi-asserted-by":"crossref","first-page":"1064","DOI":"10.1016\/j.arth.2012.01.006","article-title":"Wear Analysis of First-Generation Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty: An Average 9-Year Follow-Up","volume":"27","author":"Reynolds","year":"2012","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2014.05.008_bb0245","doi-asserted-by":"crossref","first-page":"148","DOI":"10.3109\/17453674.2011.652889","article-title":"No adverse effects of submelt-annealed highly crosslinked polyethylene in cemented cups: an RSA study of 8 patients 10years after surgery","volume":"83","author":"Rohrl","year":"2012","journal-title":"Acta Orthop"},{"key":"10.1016\/j.arth.2014.05.008_bb0250","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1007\/s11999-012-2497-y","article-title":"The 2012 Frank Stinchfield Award. Decreasing Patient Activity With Aging: Implication for Crosslinked Polyethylene Wear","volume":"471","author":"Battenberg","year":"2013","journal-title":"Clin Orthop Relat Res"},{"issue":"8","key":"10.1016\/j.arth.2014.05.008_bb0255","doi-asserted-by":"crossref","first-page":"2586","DOI":"10.1007\/s11999-013-2968-9","article-title":"Which Functional Assessments Predict Long-term Wear After Total Hip Arthroplasty?","volume":"471","author":"Takenaga","year":"2013","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2014.05.008_bb0260","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1097\/00003086-200012000-00005","article-title":"Wear is a Function of Use, Not Time","volume":"381","author":"Schmalzried","year":"2000","journal-title":"Clin Orthop Relat Res"}],"container-title":["The Journal of Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540314003155?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540314003155?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2022,4,3]],"date-time":"2022-04-03T17:06:02Z","timestamp":1649005562000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0883540314003155"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,10]]},"references-count":43,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2014,10]]}},"alternative-id":["S0883540314003155"],"URL":"https:\/\/doi.org\/10.1016\/j.arth.2014.05.008","relation":{},"ISSN":["0883-5403"],"issn-type":[{"value":"0883-5403","type":"print"}],"subject":[],"published":{"date-parts":[[2014,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Fixation and Wear With a Contemporary Acetabular Component and Cross-Linked Polyethylene at Minimum 10-Year Follow-Up","name":"articletitle","label":"Article Title"},{"value":"The Journal of Arthroplasty","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arth.2014.05.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}