{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,10]],"date-time":"2025-11-10T13:38:38Z","timestamp":1762781918949,"version":"3.40.5"},"reference-count":45,"publisher":"Elsevier BV","issue":"12","license":[{"start":{"date-parts":[[2015,12,1]],"date-time":"2015-12-01T00:00:00Z","timestamp":1448928000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","arthroplastyjournal.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Arthroplasty"],"published-print":{"date-parts":[[2015,12]]},"DOI":"10.1016\/j.arth.2015.06.039","type":"journal-article","created":{"date-parts":[[2015,6,23]],"date-time":"2015-06-23T02:05:39Z","timestamp":1435025139000},"page":"2233-2236","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Performance of Non-Cemented, Hemispherical, Rim-Fit, Hydroxyapatite Coated Acetabular Component"],"prefix":"10.1016","volume":"30","author":[{"given":"Thomas K.","family":"John","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0787-474X","authenticated-orcid":false,"given":"Gaurav","family":"Ghosh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chitranjan S.","family":"Ranawat","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amar S.","family":"Ranawat","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Morteza","family":"Meftah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.arth.2015.06.039_bb0005","doi-asserted-by":"crossref","first-page":"780","DOI":"10.2106\/JBJS.F.00222","article-title":"Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030","volume":"89","author":"Kurtz","year":"2007","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2015.06.039_bb0010","doi-asserted-by":"crossref","first-page":"171","DOI":"10.2106\/00004623-200202000-00002","article-title":"Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components","volume":"84-A","author":"Berry","year":"2002","journal-title":"J Bone Joint Surg Am"},{"issue":"4","key":"10.1016\/j.arth.2015.06.039_bb0015","doi-asserted-by":"crossref","first-page":"690","DOI":"10.2106\/00004623-200404000-00004","article-title":"Results of Charnley total hip arthroplasty at a minimum of thirty years. A concise follow-up of a previous report","volume":"86-A","author":"Callaghan","year":"2004","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"10.1016\/j.arth.2015.06.039_bb0020","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1080\/17453670710013861","article-title":"Comparison of cemented and uncemented fixation in total hip replacement: a meta-analysis","volume":"78","author":"Morshed","year":"2007","journal-title":"Acta Orthop"},{"issue":"11","key":"10.1016\/j.arth.2015.06.039_bb0025","doi-asserted-by":"crossref","first-page":"1632","DOI":"10.2106\/00004623-199811000-00010","article-title":"Total hip arthroplasty with use of second-generation cementing techniques. An eighteen-year-average follow-up study","volume":"80","author":"Smith","year":"1998","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"10.1016\/j.arth.2015.06.039_bb0030","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1302\/0301-620X.72B1.2298795","article-title":"Cementless acetabular components","volume":"72","author":"Engh","year":"1990","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2015.06.039_bb0035","doi-asserted-by":"crossref","first-page":"1130","DOI":"10.2106\/JBJS.H.00168","article-title":"Primary total hip arthroplasty with a porous coated acetabular component. A concise follow-up, at a minimum of twenty years, of previous reports","volume":"91","author":"Della Valle","year":"2009","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2015.06.039_bb0040","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.arth.2008.01.299","article-title":"Hydroxyapatite coated femoral stems in primary total hip arthroplasty: a meta-analysis","volume":"24","author":"Gandhi","year":"2009","journal-title":"J Arthroplasty"},{"issue":"4","key":"10.1016\/j.arth.2015.06.039_bb0045","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1302\/0301-620X.95B4.30445","article-title":"Primary total hip replacement with a Furlong fully hydroxyapatite-coated titanium alloy femoral component: results at a minimum follow-up of 20years","volume":"95-B","author":"Sandiford","year":"2013","journal-title":"Bone Joint J"},{"issue":"1","key":"10.1016\/j.arth.2015.06.039_bb0050","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1080\/17453670610045759","article-title":"Excellent results with femoral revision surgery using an extensively hydroxyapatite-coated stem: 59 patients followed for 10-16 years","volume":"77","author":"Reiker\u00e5s","year":"2006","journal-title":"Acta Orthop"},{"issue":"3","key":"10.1016\/j.arth.2015.06.039_bb0055","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1016\/j.arth.2007.01.027","article-title":"Ten- to twelve-year follow-up of the furlong hydroxyapatite-coated femoral stem and threaded acetabular cup in patients younger than 65years","volume":"23","author":"Gabbar","year":"2008","journal-title":"J Arthroplasty"},{"issue":"2","key":"10.1016\/j.arth.2015.06.039_bb0060","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1302\/0301-620X.75B2.8444949","article-title":"Hydroxyapatite coating converts fibrous tissue to bone around loaded implants","volume":"75","author":"Soballe","year":"1993","journal-title":"J Bone Joint Surg Br"},{"issue":"1","key":"10.1016\/j.arth.2015.06.039_bb0065","doi-asserted-by":"crossref","first-page":"43","DOI":"10.5435\/00124635-200201000-00007","article-title":"The optimal fixation of the cementless acetabular component in primary total hip arthroplasty","volume":"10","author":"Illgen","year":"2002","journal-title":"J Am Acad Orthop Surg"},{"issue":"3","key":"10.1016\/j.arth.2015.06.039_bb0070","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1016\/S0883-5403(99)90050-5","article-title":"Porous cups with and without hydroxyapatite-tricalcium phosphate coating: 23 matched pairs evaluated with radiostereometry","volume":"14","author":"Thanner","year":"1999","journal-title":"J Arthroplasty"},{"issue":"2","key":"10.1016\/j.arth.2015.06.039_bb0075","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1302\/0301-620X.78B2.0780200","article-title":"Hydroxyapatite coating of an acetabular prosthesis: effect on stability","volume":"78","author":"Moilanen","year":"1996","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2015.06.039_bb0080","doi-asserted-by":"crossref","first-page":"972","DOI":"10.1016\/j.arth.2010.09.009","article-title":"Hydroxyapatite-coated femoral stem\/porous-coated acetabulum survivorship at 15years","volume":"26","author":"Bliss","year":"2011","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2015.06.039_bb0085","doi-asserted-by":"crossref","first-page":"e82","DOI":"10.2106\/JBJS.K.00549","article-title":"Comparative long-term survivorship of uncemented acetabular components in revision total hip arthroplasty","volume":"94","author":"Kremers","year":"2012","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"10.1016\/j.arth.2015.06.039_bb0090","doi-asserted-by":"crossref","first-page":"207","DOI":"10.2106\/00004623-197254020-00001","article-title":"Total hip replacement with fixation by acrylic cement. A preliminary study of 100 consecutive McKee-Farrar prosthetic replacements","volume":"54","author":"Wilson","year":"1972","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"10.1016\/j.arth.2015.06.039_bb0095","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1302\/0301-620X.87B5.15377","article-title":"EBRA-FCA for measurement of migration of the femoral component in surface arthroplasty of the hip","volume":"87","author":"Beaul\u00e9","year":"2005","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2015.06.039_bb0100","first-page":"20","article-title":"Radiological demarcation of cemented sockets in total hip replacement","volume":"121","author":"DeLee","year":"1976","journal-title":"Clin Orthop Relat Res"},{"issue":"4 Suppl 1","key":"10.1016\/j.arth.2015.06.039_bb0105","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1054\/arth.2002.32810","article-title":"Hydroxyapatite: catalyst or conjuror?","volume":"17","author":"Rasquinha","year":"2002","journal-title":"J Arthroplasty"},{"issue":"8","key":"10.1016\/j.arth.2015.06.039_bb0110","doi-asserted-by":"crossref","first-page":"1409","DOI":"10.1016\/j.arth.2011.06.021","article-title":"Patterns of osseointegration and remodeling in femoral revision with bone loss using modular, tapered, fluted, titanium stems","volume":"26","author":"Rodriguez","year":"2011","journal-title":"J Arthroplasty"},{"issue":"3","key":"10.1016\/j.arth.2015.06.039_bb0115","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/S0883-5403(89)80020-8","article-title":"Evaluation of cementless acetabular component migration. An experimental study","volume":"4","author":"Massin","year":"1989","journal-title":"J Arthroplasty"},{"issue":"2","key":"10.1016\/j.arth.2015.06.039_bb0120","doi-asserted-by":"crossref","first-page":"217","DOI":"10.2106\/00004623-197860020-00014","article-title":"Dislocations after total hip-replacement arthroplasties","volume":"60","author":"Lewinnek","year":"1978","journal-title":"J Bone Joint Surg"},{"issue":"7","key":"10.1016\/j.arth.2015.06.039_bb0125","doi-asserted-by":"crossref","first-page":"1152","DOI":"10.1016\/j.arth.2012.11.021","article-title":"Factors influencing revision risk following 15 740 single-brand hybrid hip arthroplasties: a cohort study from a National Joint Registry","volume":"28","author":"Jameson","year":"2013","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2015.06.039_bb0130","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1097\/01.blo.0000194084.67364.6c","article-title":"A titanium-encased alumina ceramic bearing for total hip arthroplasty: 3- to 5-year results","volume":"441","author":"D\u2019Antonio","year":"2005","journal-title":"Clin Orthop Relat Res"},{"issue":"11","key":"10.1016\/j.arth.2015.06.039_bb0135","doi-asserted-by":"crossref","first-page":"2526","DOI":"10.2106\/00004623-200411000-00028","article-title":"Hydroxyapatite-coated prostheses in total hip and knee arthroplasty. The Journal of bone and joint surgery","volume":"86-A","author":"Dumbleton","year":"2004","journal-title":"J Bone Joint Surg Am"},{"issue":"4","key":"10.1016\/j.arth.2015.06.039_bb0140","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1002\/(SICI)1097-4636(19980315)39:4<580::AID-JBM12>3.0.CO;2-B","article-title":"Thermal processing of hydroxyapatite for coating production","volume":"39","author":"Gross","year":"1998","journal-title":"J Biomed Mater Res"},{"issue":"3","key":"10.1016\/j.arth.2015.06.039_bb0145","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/0883-5403(92)90052-R","article-title":"Stability of press-fit acetabular cups","volume":"7","author":"Adler","year":"1992","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2015.06.039_bb0150","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1097\/01.blo.0000201149.14078.50","article-title":"Radiographic signs of osseointegration in porous-coated acetabular components","volume":"444","author":"Moore","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2015.06.039_bb0155","doi-asserted-by":"crossref","first-page":"619","DOI":"10.3109\/17453679308994584","article-title":"Histology of porous-coated acetabular components","volume":"64","author":"Sumner","year":"1993","journal-title":"Acta Orthop Scand"},{"key":"10.1016\/j.arth.2015.06.039_bb0160","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1615\/JLongTermEffMedImplants.v17.i3.20","article-title":"Options for acetabular fixation","volume":"17","author":"Klika","year":"2007","journal-title":"J Long Term Eff Med Implants"},{"key":"10.1016\/j.arth.2015.06.039_bb0165","doi-asserted-by":"crossref","first-page":"155","DOI":"10.3109\/17453674.2011.572251","article-title":"Comparison of trabecular metal cups and titanium fibre-mesh in primary hip arthroplasty","volume":"82","author":"Baad\u2013Hansen","year":"2011","journal-title":"Acta Orthop"},{"issue":"5","key":"10.1016\/j.arth.2015.06.039_bb0170","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1007\/s00264-002-0394-9","article-title":"Bone ingrowth on a smooth-surfaced hydroxyapatite-coated acetabular cup","volume":"26","author":"Chung","year":"2002","journal-title":"Int Orthop"},{"key":"10.1016\/j.arth.2015.06.039_bb0175","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1054\/arth.2002.29394","article-title":"Medium-term results of the ABG total hip arthroplasty in young patients","volume":"17","author":"Giannikas","year":"2002","journal-title":"J Arthroplasty"},{"issue":"3","key":"10.1016\/j.arth.2015.06.039_bb0180","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1016\/j.arth.2013.07.037","article-title":"Uncemented porous tantalum acetabular components: early follow-up and failures in 613 primary total hip arthroplasties","volume":"29","author":"Noiseux","year":"2014","journal-title":"J Arthroplasty"},{"issue":"4","key":"10.1016\/j.arth.2015.06.039_bb0185","doi-asserted-by":"crossref","first-page":"e390","DOI":"10.3928\/01477447-20130327-10","article-title":"Excellent results of primary THA using a highly porous titanium cup","volume":"36","author":"Naziri","year":"2013","journal-title":"Orthopedics"},{"issue":"2","key":"10.1016\/j.arth.2015.06.039_bb0190","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1007\/s11999-010-1500-8","article-title":"A monoblock porous tantalum acetabular cup has no osteolysis on CT at 10years","volume":"469","author":"Moen","year":"2011","journal-title":"Clin Orthop Relat Res"},{"issue":"6","key":"10.1016\/j.arth.2015.06.039_bb0200","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1007\/s00776-013-0456-4","article-title":"Results at a minimum of 10years of follow-up for AMS and PerFix HA-coated cementless total hip arthroplasty: impact of cross-linked polyethylene on implant longevity","volume":"18","author":"Nakashima","year":"2013","journal-title":"J Orthop Sci"},{"issue":"2","key":"10.1016\/j.arth.2015.06.039_bb0205","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1177\/230949901101900207","article-title":"Cementless total hip arthroplasty using titanium, plasma-sprayed implants: a study with 10 to 15years of follow-up","volume":"19","author":"Sanz-Reig","year":"2011","journal-title":"J Orthop Surg (Hong Kong)"},{"issue":"3","key":"10.1016\/j.arth.2015.06.039_bb0210","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1016\/j.arth.2007.10.034","article-title":"Midterm survivorship of a press-fit, plasma-sprayed, tri-spike acetabular component","volume":"24","author":"Klaassen","year":"2009","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2015.06.039_bb0215","doi-asserted-by":"crossref","DOI":"10.1155\/2014\/302969","article-title":"Clinical and radiographic outcomes with a hydroxyapatite and porous coated cup design","volume":"2014","author":"Wang","year":"2014","journal-title":"Adv Orthop Surg"},{"issue":"2","key":"10.1016\/j.arth.2015.06.039_bb0220","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1054\/arth.2003.50039","article-title":"A 10-year minimum follow-up of hydroxyapatite-coated threaded cups: clinical, radiographic and survivorship analyses with comparison to the literature","volume":"18","author":"Epinette","year":"2003","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2015.06.039_bb0225","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1080\/17453670610045704","article-title":"Uncemented total hip arthroplasty for primary osteoarthritis in young patients: a mid-to long-term follow-up study from the Finnish Arthroplasty Register","volume":"77","author":"Eskelinen","year":"2006","journal-title":"Acta Orthop"},{"key":"10.1016\/j.arth.2015.06.039_bb0230","doi-asserted-by":"crossref","first-page":"53","DOI":"10.3109\/17453670903413178","article-title":"Increased risk of revision of acetabular cups coated with hydroxyapatite: a Swedish Hip Arthroplasty Register study involving 8,043 total hip replacements","volume":"81","author":"Lazarinis","year":"2010","journal-title":"Acta Orthop"}],"container-title":["The Journal of Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540315005513?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540315005513?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,8,27]],"date-time":"2019-08-27T11:41:01Z","timestamp":1566906061000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0883540315005513"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,12]]},"references-count":45,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2015,12]]}},"alternative-id":["S0883540315005513"],"URL":"https:\/\/doi.org\/10.1016\/j.arth.2015.06.039","relation":{},"ISSN":["0883-5403"],"issn-type":[{"type":"print","value":"0883-5403"}],"subject":[],"published":{"date-parts":[[2015,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Performance of Non-Cemented, Hemispherical, Rim-Fit, Hydroxyapatite Coated Acetabular Component","name":"articletitle","label":"Article Title"},{"value":"The Journal of Arthroplasty","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arth.2015.06.039","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}