{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T17:40:35Z","timestamp":1790185235353,"version":"4.1.0"},"reference-count":38,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2016,1,1]],"date-time":"2016-01-01T00:00:00Z","timestamp":1451606400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","arthroplastyjournal.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Arthroplasty"],"published-print":{"date-parts":[[2016,1]]},"DOI":"10.1016\/j.arth.2015.07.007","type":"journal-article","created":{"date-parts":[[2015,7,11]],"date-time":"2015-07-11T09:15:12Z","timestamp":1436606112000},"page":"290-294","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":15,"title":["Comparison of Tibial Insert Polyethylene Damage in Rotating Hinge and Highly Constrained Total Knee Arthroplasty: A Retrieval Analysis"],"prefix":"10.1016","volume":"31","author":[{"given":"Kamal","family":"Bali","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Douglas D.","family":"Naudie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James L.","family":"Howard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard W.","family":"McCalden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven J.","family":"MacDonald","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew G.","family":"Teeter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.arth.2015.07.007_bb0005","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1080\/000164700317411852","article-title":"Patient satisfaction after knee arthroplasty: a report on 27,372 knees operated on between 1981 and 1995 in Sweden","volume":"71","author":"Robertsson","year":"2000","journal-title":"Acta Orthop Scand"},{"key":"10.1016\/j.arth.2015.07.007_bb0010","doi-asserted-by":"crossref","first-page":"994","DOI":"10.2106\/JBJS.M.00373","article-title":"All-polyethylene versus metal-backed tibial components\u2014an analysis of 27,733 cruciate-retaining total knee replacements from the Swedish Knee Arthroplasty Register","volume":"96","author":"Gudnason","year":"2014","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2015.07.007_bb0015","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1007\/s11999-010-1536-9","article-title":"What is the evidence for total knee arthroplasty in young patients?: a systematic review of the literature","volume":"469","author":"Keeney","year":"2011","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2015.07.007_bb0020","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1243\/0954411001535219","article-title":"Biological reactions to wear debris in total joint replacement","volume":"214","author":"Ingham","year":"2000","journal-title":"Proc Inst Mech Eng H"},{"key":"10.1016\/j.arth.2015.07.007_bb0025","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1097\/00003086-200211000-00003","article-title":"Insall Award paper. Why are total knee arthroplasties failing today?","volume":"404","author":"Sharkey","year":"2002","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2015.07.007_bb0030","doi-asserted-by":"crossref","first-page":"53","DOI":"10.5435\/00124635-200701000-00006","article-title":"Wear and osteolysis around total knee arthroplasty","volume":"15","author":"Naudie","year":"2007","journal-title":"J Am Acad Orthop Surg"},{"key":"10.1016\/j.arth.2015.07.007_bb0035","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1243\/09544119JEIM336","article-title":"The effect of polyethylene thickness in fixed- and mobile-bearing total knee replacements","volume":"222","author":"Shi","year":"2008","journal-title":"Proc Inst Mech Eng H"},{"key":"10.1016\/j.arth.2015.07.007_bb0040","first-page":"83","article-title":"Effect of polyethylene quality on wear in total knee arthroplasty","volume":"317","author":"Tanner","year":"1995","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2015.07.007_bb0045","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1097\/00003086-199610000-00023","article-title":"Effects of sterilization on wear in total knee arthroplasty","volume":"331","author":"White","year":"1996","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2015.07.007_bb0050","doi-asserted-by":"crossref","first-page":"2798","DOI":"10.1007\/s11999-008-0470-6","article-title":"Polyethylene wear is influenced by manufacturing technique in modular TKA","volume":"466","author":"Lombardi","year":"2008","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2015.07.007_bb0055","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/j.jbiomech.2004.02.015","article-title":"The influence of design, materials and kinematics on the in vitro wear of total knee replacements","volume":"38","author":"McEwen","year":"2005","journal-title":"J Biomech"},{"key":"10.1016\/j.arth.2015.07.007_bb0060","article-title":"Does increased topside conformity in modular total knee arthroplasty lead to increased backside wear?","author":"Schwarzkopf","year":"2014","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2015.07.007_bb0065","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1007\/s11999-012-2387-3","article-title":"The 2012 Mark Coventry award: a retrieval analysis of high flexion versus posterior-stabilized tibial inserts","volume":"471","author":"Paterson","year":"2013","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2015.07.007_bb0070","doi-asserted-by":"crossref","first-page":"390","DOI":"10.2106\/00004623-200103000-00011","article-title":"Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris","volume":"83","author":"Puloski","year":"2001","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2015.07.007_bb0075","doi-asserted-by":"crossref","first-page":"1814","DOI":"10.1007\/s11999-012-2274-y","article-title":"Surface damage versus tibial polyethylene insert conformity: a retrieval study","volume":"470","author":"Wimmer","year":"2012","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2015.07.007_bb0080","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1097\/00003086-200006000-00036","article-title":"The effects of conformity and load in total knee replacement","volume":"375","author":"Kuster","year":"2000","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2015.07.007_bb0085","doi-asserted-by":"crossref","first-page":"375.e17","DOI":"10.1016\/j.arth.2012.04.029","article-title":"Repeated early failure of a newly designed hinged knee system","volume":"28","author":"Lee","year":"2013","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2015.07.007_bb0090","doi-asserted-by":"crossref","first-page":"e39","DOI":"10.1016\/j.ocl.2012.07.006","article-title":"Retrieval analysis of nonmodular constrained tibial inserts after primary total knee replacement","volume":"43","author":"Padgett","year":"2012","journal-title":"Orthop Clin North Am"},{"key":"10.1016\/j.arth.2015.07.007_bb0095","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1097\/00003086-198803000-00024","article-title":"An evaluation of the mechanical failure modalities of a rotating hinge knee prosthesis","volume":"228","author":"Kester","year":"1988","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2015.07.007_bb0100","first-page":"207","article-title":"Managing instability in total knee arthroplasty with constrained and linked implants","volume":"53","author":"Naudie","year":"2004","journal-title":"Instr Course Lect"},{"key":"10.1016\/j.arth.2015.07.007_bb0105","doi-asserted-by":"crossref","first-page":"780","DOI":"10.2106\/JBJS.F.00222","article-title":"Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030","volume":"89","author":"Kurtz","year":"2007","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2015.07.007_bb0110","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.arth.2008.01.003","article-title":"Analysis of retrieved ultra-high-molecular-weight polyethylene tibial components from rotating-platform total knee arthroplasty","volume":"24","author":"Garcia","year":"2009","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2015.07.007_bb0115","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1002\/jbm.820170510","article-title":"Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses","volume":"17","author":"Hood","year":"1983","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.arth.2015.07.007_bb0120","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1016\/S0883-5403(97)90024-3","article-title":"Wear in retrieved condylar knee arthroplasties. A comparison of wear in different designs of 280 retrieved condylar knee prostheses","volume":"12","author":"Blunn","year":"1997","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2015.07.007_bb0125","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1097\/00003086-199203000-00016","article-title":"Wear of polyethylene in total joint replacements. Observations from retrieved PCA knee implants","volume":"276","author":"Wright","year":"1992","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2015.07.007_bb0130","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1097\/00003086-199402000-00005","article-title":"Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty","volume":"299","author":"Wasielewski","year":"1994","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2015.07.007_bb0135","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1007\/s11999-012-2530-1","article-title":"Rotating-platform has no surface damage advantage over fixed-bearing TKA","volume":"471","author":"Stoner","year":"2013","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2015.07.007_bb0140","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1302\/0301-620X.92B4.22560","article-title":"Wear-pattern analysis in retrieved tibial inserts of mobile-bearing and fixed-bearing total knee prostheses","volume":"92","author":"Lu","year":"2010","journal-title":"J Bone Joint Surg (Br)"},{"issue":"6 Suppl.","key":"10.1016\/j.arth.2015.07.007_bb0145","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.arth.2009.03.010","article-title":"Analysis of wear in retrieved mobile and fixed bearing knee inserts","volume":"24","author":"Engh","year":"2009","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2015.07.007_bb0150","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1007\/s11999-010-1557-4","article-title":"Wear damage in mobile-bearing TKA is as severe as that in fixed-bearing TKA","volume":"469","author":"Kelly","year":"2011","journal-title":"Clin Orthop Relat Res"},{"issue":"Suppl. 1","key":"10.1016\/j.arth.2015.07.007_bb0155","doi-asserted-by":"crossref","first-page":"240","DOI":"10.2106\/JBJS.J.00157","article-title":"Mobile and fixed-bearing (all-polyethylene tibial component) total knee arthroplasty designs: surgical technique","volume":"92","author":"Luna","year":"2010","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2015.07.007_bb0160","doi-asserted-by":"crossref","first-page":"481","DOI":"10.2106\/JBJS.K.00315","article-title":"Randomized clinical trial of rotating-platform and fixed-bearing total knee arthroplasty: no clinically detectable differences at five years","volume":"94","author":"Kalisvaart","year":"2012","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2015.07.007_bb0165","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1007\/s00167-009-0909-7","article-title":"Clinical and radiological outcomes of fixed- versus mobile-bearing total knee replacement: a meta-analysis","volume":"18","author":"Smith","year":"2010","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.arth.2015.07.007_bb0170","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1302\/0301-620X.95B8.31310","article-title":"Is there reduced polyethylene wear and longer survival when using a mobile-bearing design in total knee replacement? A meta-analysis of randomised and non-randomised controlled trials","volume":"95","author":"Zeng","year":"2013","journal-title":"Bone Joint J"},{"issue":"A1 Suppl.","key":"10.1016\/j.arth.2015.07.007_bb0175","first-page":"69","article-title":"Wear, creep, and frictional heating of femoral implant articulating surfaces and the effect on long-term performance\u2014part II, Friction, heating, and torque","volume":"22","author":"Davidson","year":"1988","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.arth.2015.07.007_bb0180","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1002\/jbm.820280111","article-title":"Macrophage\/particle interactions: effect of size, composition and surface area","volume":"28","author":"Shanbhag","year":"1994","journal-title":"J Biomed Mater Res"},{"key":"10.1016\/j.arth.2015.07.007_bb0185","doi-asserted-by":"crossref","first-page":"1038","DOI":"10.1016\/S0736-0266(02)00015-3","article-title":"Particle size and morphology of UHMWPE wear debris in failed total knee arthroplasties\u2014a comparison between mobile bearing and fixed bearing knees","volume":"20","author":"Huang","year":"2002","journal-title":"J Orthop Res"},{"key":"10.1016\/j.arth.2015.07.007_bb0190","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1016\/j.arth.2010.07.010","article-title":"In vivo oxidation contributes to delamination but not pitting in polyethylene components for total knee arthroplasty","volume":"26","author":"Medel","year":"2011","journal-title":"J Arthroplasty"}],"container-title":["The Journal of Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540315006063?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540315006063?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2022,5,17]],"date-time":"2022-05-17T23:43:59Z","timestamp":1652831039000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0883540315006063"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,1]]},"references-count":38,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2016,1]]}},"alternative-id":["S0883540315006063"],"URL":"https:\/\/doi.org\/10.1016\/j.arth.2015.07.007","relation":{},"ISSN":["0883-5403"],"issn-type":[{"value":"0883-5403","type":"print"}],"subject":[],"published":{"date-parts":[[2016,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of Tibial Insert Polyethylene Damage in Rotating Hinge and Highly Constrained Total Knee Arthroplasty: A Retrieval Analysis","name":"articletitle","label":"Article Title"},{"value":"The Journal of Arthroplasty","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arth.2015.07.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2016 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}