{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T03:54:13Z","timestamp":1784260453300,"version":"3.55.0"},"reference-count":29,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2016,1,1]],"date-time":"2016-01-01T00:00:00Z","timestamp":1451606400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","arthroplastyjournal.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Arthroplasty"],"published-print":{"date-parts":[[2016,1]]},"DOI":"10.1016\/j.arth.2015.07.039","type":"journal-article","created":{"date-parts":[[2015,8,1]],"date-time":"2015-08-01T19:19:59Z","timestamp":1438456799000},"page":"264-268","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":139,"title":["Diagnosis and Management of Adverse Local Tissue Reactions Secondary to Corrosion at the Head-Neck Junction in Patients With Metal on Polyethylene Bearings"],"prefix":"10.1016","volume":"31","author":[{"given":"Darren R.","family":"Plummer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard A.","family":"Berger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wayne G.","family":"Paprosky","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Scott M.","family":"Sporer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joshua J.","family":"Jacobs","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Craig J.","family":"Della Valle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.arth.2015.07.039_bb0005","first-page":"91","article-title":"The tradeoffs associated with modular hip prostheses","volume":"311","author":"Collier","year":"1995","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2015.07.039_bb0010","first-page":"94","article-title":"Local and distant products from modularity","volume":"319","author":"Jacobs","year":"1995","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2015.07.039_bb0015","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1097\/00003086-199401000-00013","article-title":"Wear and corrosion of modular interfaces in total hip replacements","volume":"298","author":"Cook","year":"1994","journal-title":"Clin Orthop Relat Res"},{"issue":"10 Suppl","key":"10.1016\/j.arth.2015.07.039_bb0020","first-page":"2","article-title":"Clinical results of a modular neck hip system: hitting the \u201cbull's-eye\u201d more accurately","volume":"39","author":"Duwelius","year":"2010","journal-title":"Am J Orthop"},{"issue":"18","key":"10.1016\/j.arth.2015.07.039_bb0025","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.2106\/JBJS.K.01352","article-title":"Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty","volume":"94","author":"Cooper","year":"2012","journal-title":"J Bone Joint Surg Am"},{"issue":"10","key":"10.1016\/j.arth.2015.07.039_bb0030","doi-asserted-by":"crossref","first-page":"865","DOI":"10.2106\/JBJS.L.01042","article-title":"Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck","volume":"95","author":"Cooper","year":"2013","journal-title":"J Bone Joint Surg Am"},{"issue":"10","key":"10.1016\/j.arth.2015.07.039_bb0035","doi-asserted-by":"crossref","first-page":"1427","DOI":"10.1302\/0301-620X.93B10.27645","article-title":"Adverse reaction to metal release from a modular metal-on-polyethylene hip prosthesis","volume":"93","author":"Lindgren","year":"2011","journal-title":"J Bone Joint Surg Br"},{"issue":"10","key":"10.1016\/j.arth.2015.07.039_bb0040","doi-asserted-by":"crossref","first-page":"e71","DOI":"10.2106\/JBJS.M.00169","article-title":"That's why we call it BIOmechanics!: commentary on an article by H. John Cooper, MD, et al.: \u201cAdverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck\u201d","volume":"95","author":"Padgett","year":"2013","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"10.1016\/j.arth.2015.07.039_bb0045","doi-asserted-by":"crossref","first-page":"493.e413","DOI":"10.1016\/j.arth.2011.07.015","article-title":"Pseudotumor in a well-fixed metal-on-polyethylene uncemented hip arthroplasty","volume":"27","author":"Mao","year":"2012","journal-title":"J Arthroplast"},{"issue":"2","key":"10.1016\/j.arth.2015.07.039_bb0050","doi-asserted-by":"crossref","first-page":"324.e325","DOI":"10.1016\/j.arth.2011.03.013","article-title":"Inflammatory pseudotumor complicating metal-on-highly cross-linked polyethylene total hip arthroplasty","volume":"27","author":"Walsh","year":"2012","journal-title":"J Arthroplast"},{"key":"10.1016\/j.arth.2015.07.039_bb0055","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1097\/00003086-200208000-00018","article-title":"A multicenter retrieval study of the taper interfaces of modular hip prostheses","volume":"401","author":"Goldberg","year":"2002","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"10.1016\/j.arth.2015.07.039_bb0060","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1302\/0301-620X.73B4.2071637","article-title":"Corrosion of modular hip prostheses","volume":"73","author":"Mathiesen","year":"1991","journal-title":"J Bone Joint Surg Br"},{"issue":"7","key":"10.1016\/j.arth.2015.07.039_bb0065","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.1016\/j.arth.2011.11.007","article-title":"Femoral stem fracture and in vivo corrosion of retrieved modular femoral hips","volume":"27","author":"Huot Carlson","year":"2012","journal-title":"J Arthroplast"},{"issue":"4","key":"10.1016\/j.arth.2015.07.039_bb0070","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1302\/0301-620X.74B4.1624507","article-title":"Corrosion between the components of modular femoral hip prostheses","volume":"74","author":"Collier","year":"1992","journal-title":"J Bone Joint Surg Br"},{"issue":"7","key":"10.1016\/j.arth.2015.07.039_bb0075","doi-asserted-by":"crossref","first-page":"1169.e1165","DOI":"10.1016\/j.arth.2009.07.015","article-title":"Failure of the modular neck in a total hip arthroplasty","volume":"25","author":"Dangles","year":"2010","journal-title":"J Arthroplast"},{"issue":"6","key":"10.1016\/j.arth.2015.07.039_bb0080","doi-asserted-by":"crossref","first-page":"1522","DOI":"10.2106\/JBJS.I.00980","article-title":"Corrosion-induced fracture of a double-modular hip prosthesis: a case report","volume":"92","author":"Atwood","year":"2010","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"10.1016\/j.arth.2015.07.039_bb0085","doi-asserted-by":"crossref","first-page":"110","DOI":"10.2106\/00004623-199401000-00014","article-title":"Intergranular corrosion-fatigue failure of cobalt-alloy femoral stems. A failure analysis of two implants","volume":"76","author":"Gilbert","year":"1994","journal-title":"J Bone Joint Surg Am"},{"issue":"10","key":"10.1016\/j.arth.2015.07.039_bb0090","doi-asserted-by":"crossref","first-page":"1447","DOI":"10.2106\/00004623-199810000-00006","article-title":"Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study","volume":"80","author":"Jacobs","year":"1998","journal-title":"J Bone Joint Surg Am"},{"issue":"4","key":"10.1016\/j.arth.2015.07.039_bb0095","doi-asserted-by":"crossref","first-page":"737","DOI":"10.2106\/00004623-196951040-00012","article-title":"Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation","volume":"51","author":"Harris","year":"1969","journal-title":"J Bone Joint Surg Am"},{"issue":"9","key":"10.1016\/j.arth.2015.07.039_bb0100","doi-asserted-by":"crossref","first-page":"1768","DOI":"10.1016\/j.arth.2014.04.039","article-title":"Midterm results of a femoral stem with a modular neck design: clinical outcomes and metal ion analysis","volume":"29","author":"Silverton","year":"2014","journal-title":"J Arthroplast"},{"issue":"5","key":"10.1016\/j.arth.2015.07.039_bb0105","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1002\/jbm.820150509","article-title":"Investigations on the galvanic corrosion of multialloy total hip prostheses","volume":"15","author":"Lucas","year":"1981","journal-title":"J Biomed Mater Res"},{"issue":"12","key":"10.1016\/j.arth.2015.07.039_bb0110","doi-asserted-by":"crossref","first-page":"1533","DOI":"10.1002\/jbm.820271210","article-title":"In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling","volume":"27","author":"Gilbert","year":"1993","journal-title":"J Biomed Mater Res"},{"issue":"329 Suppl.","key":"10.1016\/j.arth.2015.07.039_bb0115","doi-asserted-by":"crossref","first-page":"S187","DOI":"10.1097\/00003086-199608001-00017","article-title":"Tissue reaction to metal on metal total hip prostheses","author":"Doorn","year":"1996","journal-title":"Clin Orthop Relat Res"},{"issue":"9","key":"10.1016\/j.arth.2015.07.039_bb0120","doi-asserted-by":"crossref","first-page":"2321","DOI":"10.1007\/s11999-010-1372-y","article-title":"Histological features of pseudotumor-like tissues from metal-on-metal hips","volume":"468","author":"Campbell","year":"2010","journal-title":"Clin Orthop Relat Res"},{"issue":"17","key":"10.1016\/j.arth.2015.07.039_bb0125","doi-asserted-by":"crossref","first-page":"1554","DOI":"10.2106\/JBJS.L.00716","article-title":"High prevalence of pseudotumors in patients with a Birmingham hip resurfacing prosthesis: a prospective cohort study of one hundred and twenty-nine patients","volume":"95","author":"Bisschop","year":"2013","journal-title":"J Bone Joint Surg Am"},{"issue":"8","key":"10.1016\/j.arth.2015.07.039_bb0130","doi-asserted-by":"crossref","first-page":"1238","DOI":"10.2106\/00004623-198870080-00017","article-title":"Formation of a fulminant soft-tissue pseudotumor after uncemented hip arthroplasty. A case report","volume":"70","author":"Svensson","year":"1988","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"10.1016\/j.arth.2015.07.039_bb0135","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1007\/s11999-009-1029-x","article-title":"The John Charnley Award: metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial","volume":"468","author":"Garbuz","year":"2010","journal-title":"Clin Orthop Relat Res"},{"issue":"6","key":"10.1016\/j.arth.2015.07.039_bb0140","doi-asserted-by":"crossref","first-page":"512","DOI":"10.2106\/JBJS.L.00471","article-title":"Ten-year outcome of serum metal ion levels after primary total hip arthroplasty: a concise follow-up of a previous report*","volume":"95","author":"Levine","year":"2013","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2015.07.039_bb0145","series-title":"Abstract","article-title":"Diagnosis of periprosthetic joint infection in revision hip arthroplasty with a metal-on-metal bearing or corrosion","author":"Yi","year":"2013"}],"container-title":["The Journal of Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540315007172?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540315007172?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2022,5,19]],"date-time":"2022-05-19T21:02:53Z","timestamp":1652994173000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0883540315007172"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,1]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2016,1]]}},"alternative-id":["S0883540315007172"],"URL":"https:\/\/doi.org\/10.1016\/j.arth.2015.07.039","relation":{},"ISSN":["0883-5403"],"issn-type":[{"value":"0883-5403","type":"print"}],"subject":[],"published":{"date-parts":[[2016,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Diagnosis and Management of Adverse Local Tissue Reactions Secondary to Corrosion at the Head-Neck Junction in Patients With Metal on Polyethylene Bearings","name":"articletitle","label":"Article Title"},{"value":"The Journal of Arthroplasty","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arth.2015.07.039","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2016 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}