{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T22:52:16Z","timestamp":1781563936460,"version":"3.54.5"},"reference-count":16,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2018,3,1]],"date-time":"2018-03-01T00:00:00Z","timestamp":1519862400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","arthroplastyjournal.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Arthroplasty"],"published-print":{"date-parts":[[2018,3]]},"DOI":"10.1016\/j.arth.2017.10.009","type":"journal-article","created":{"date-parts":[[2017,10,16]],"date-time":"2017-10-16T06:15:36Z","timestamp":1508134536000},"page":"766-770","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":58,"title":["Rotating Hinge Implants for Complex Primary and Revision Total Knee Arthroplasty"],"prefix":"10.1016","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7067-3249","authenticated-orcid":false,"given":"Sean M.","family":"Kearns","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian M.","family":"Culp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel D.","family":"Bohl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Scott M.","family":"Sporer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Craig J.","family":"Della Valle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brett R.","family":"Levine","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.arth.2017.10.009_bib1","doi-asserted-by":"crossref","first-page":"847","DOI":"10.3928\/01477447-20060901-32","article-title":"The role of implant constraint in revision TKA: striking the balance","volume":"29","author":"Lombardi","year":"2006","journal-title":"Orthopedics"},{"issue":"9 Suppl","key":"10.1016\/j.arth.2017.10.009_bib2","first-page":"S80","article-title":"Total knee arthroplasty with modular rotating-platform hinge","volume":"29","author":"Jones","year":"2006","journal-title":"Orthopedics"},{"key":"10.1016\/j.arth.2017.10.009_bib3","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1016\/j.arth.2013.12.013","article-title":"Primary rotating-hinge total knee arthroplasty: good outcomes at mid-term follow-up","volume":"29","author":"Kowalczewski","year":"2014","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2017.10.009_bib4","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1016\/j.arth.2007.05.055","article-title":"The role of the rotating hinge prosthesis in the salvage arthroplasty setting","volume":"23","author":"Deehan","year":"2008","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2017.10.009_bib5","doi-asserted-by":"crossref","first-page":"2173","DOI":"10.1016\/j.arth.2015.06.033","article-title":"Intermediate-term results of 142 single-design, rotating-hinge implants: frequent complications may not preclude salvage of severely affected knees","volume":"30","author":"Farid","year":"2015","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2017.10.009_bib6","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/j.arth.2012.05.008","article-title":"Comparison of mechanical and nonmechanical failure rates associated with rotating hinged total knee arthroplasty in nontumor patients","volume":"28","author":"Smith","year":"2013","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2017.10.009_bib7","doi-asserted-by":"crossref","first-page":"324","DOI":"10.2106\/JBJS.16.00307","article-title":"Long-term results after total knee arthroplasty with contemporary rotating-hinge prostheses","volume":"99","author":"Cottino","year":"2017","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2017.10.009_bib8","first-page":"1735","article-title":"Rotating hinged total knee replacement: use with caution","volume":"89","author":"Pour","year":"2007","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2017.10.009_bib9","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.1007\/s11999-012-2736-2","article-title":"Case report: failure of rotating-hinge total knee prosthesis by disengagement of the hinge-post extension","volume":"471","author":"Biswas","year":"2013","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2017.10.009_bib10","doi-asserted-by":"crossref","first-page":"977.e5","DOI":"10.1016\/j.arth.2010.08.008","article-title":"Failure of the tibial insert in a rotating hinge total knee arthroplasty","volume":"26","author":"Schwarzkopf","year":"2011","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2017.10.009_bib11","first-page":"9","article-title":"The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system","author":"Ewald","year":"1989","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2017.10.009_bib12","doi-asserted-by":"crossref","first-page":"279","DOI":"10.2106\/JBJS.N.00759","article-title":"Extensor mechanism allograft reconstruction for extensor mechanism failure following total knee arthroplasty","volume":"97","author":"Brown","year":"2015","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2017.10.009_bib13","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1016\/j.arth.2012.10.003","article-title":"Intra-operative periprosthetic fractures associated with press fit stems in revision total knee arthroplasty: incidence, management, and outcomes","volume":"28","author":"Cipriano","year":"2013","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2017.10.009_bib14","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1097\/00003086-200111000-00037","article-title":"The kinematic rotating hinge prosthesis for complex knee arthroplasty","author":"Springer","year":"2001","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2017.10.009_bib15","doi-asserted-by":"crossref","first-page":"375.e17","DOI":"10.1016\/j.arth.2012.04.029","article-title":"Repeated early failure of a newly designed hinged knee system","volume":"28","author":"Lee","year":"2013","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2017.10.009_bib16","doi-asserted-by":"crossref","first-page":"e325","DOI":"10.3928\/01477447-20120222-34","article-title":"Rotating-hinge total knee for revision total knee arthroplasty","volume":"35","author":"Bistolfi","year":"2012","journal-title":"Orthopedics"}],"container-title":["The Journal of Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540317309038?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540317309038?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2022,8,4]],"date-time":"2022-08-04T17:25:48Z","timestamp":1659633948000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0883540317309038"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3]]},"references-count":16,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2018,3]]}},"alternative-id":["S0883540317309038"],"URL":"https:\/\/doi.org\/10.1016\/j.arth.2017.10.009","relation":{},"ISSN":["0883-5403"],"issn-type":[{"value":"0883-5403","type":"print"}],"subject":[],"published":{"date-parts":[[2018,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Rotating Hinge Implants for Complex Primary and Revision Total Knee Arthroplasty","name":"articletitle","label":"Article Title"},{"value":"The Journal of Arthroplasty","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arth.2017.10.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}