{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T13:41:31Z","timestamp":1790862091292,"version":"4.1.0"},"reference-count":58,"publisher":"Elsevier BV","issue":"7","license":[{"start":{"date-parts":[[2018,7,1]],"date-time":"2018-07-01T00:00:00Z","timestamp":1530403200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","arthroplastyjournal.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Arthroplasty"],"published-print":{"date-parts":[[2018,7]]},"DOI":"10.1016\/j.arth.2018.02.011","type":"journal-article","created":{"date-parts":[[2018,2,12]],"date-time":"2018-02-12T12:41:07Z","timestamp":1518439267000},"page":"2279-2286","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":28,"title":["Higher Prevalence of Mixed or Solid Pseudotumors in Metal-on-Polyethylene Total Hip Arthroplasty Compared With Metal-on-Metal Total Hip Arthroplasty and Resurfacing Hip Arthroplasty"],"prefix":"10.1016","volume":"33","author":[{"given":"Mette Holm","family":"Hjorth","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Inger","family":"Mechlenburg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kjeld","family":"Soballe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lone","family":"Roemer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stig Storgaard","family":"Jakobsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maiken","family":"Stilling","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.arth.2018.02.011_bib1","author":"Medicines and A"},{"key":"10.1016\/j.arth.2018.02.011_bib2","author":"FDA"},{"key":"10.1016\/j.arth.2018.02.011_bib3","doi-asserted-by":"crossref","first-page":"e4","DOI":"10.2106\/JBJS.M.00160","article-title":"Risk stratification algorithm for management of patients with metal-on-metal hip arthroplasty: consensus statement of the American Association of hip and knee Surgeons, the American Academy of Orthopaedic Surgeons, and the hip Society 1","volume":"96","author":"Kwon","year":"2014","journal-title":"J\u00a0Bone Joint Surg Am"},{"issue":"11 Suppl A","key":"10.1016\/j.arth.2018.02.011_bib4","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1302\/0301-620X.94B11.30680","article-title":"The Hip Society: algorithmic approach to diagnosis and management of metal-on-metal arthroplasty 1","volume":"94","author":"Lombardi","year":"2012","journal-title":"J\u00a0Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2018.02.011_bib5","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/j.otsr.2013.01.005","article-title":"European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing 2","volume":"99","author":"Hannemann","year":"2013","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.arth.2018.02.011_bib6","doi-asserted-by":"crossref","first-page":"2015","DOI":"10.2106\/JBJS.L.01481","article-title":"Relationship of plasma metal ions and clinical and imaging findings in patients with ASR XL metal-on-metal total hip replacements","volume":"95","author":"Chang","year":"2013","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2018.02.011_bib7","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1302\/0301-620X.92B3.23281","article-title":"Analysis of wear of retrieved metal-on-metal hip resurfacing implants revised due to pseudotumours","volume":"92","author":"Kwon","year":"2010","journal-title":"J\u00a0Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2018.02.011_bib8","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1007\/s00402-015-2165-2","article-title":"Pseudotumor formation and serum ions after large head metal-on-metal stemmed total hip replacement. Risk factors, time course and revisions in 706 hips","volume":"135","author":"Bosker","year":"2015","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.arth.2018.02.011_bib9","doi-asserted-by":"crossref","first-page":"317","DOI":"10.2106\/JBJS.J.01508","article-title":"Pseudotumors in association with well-functioning metal-on-metal hip prostheses: a case-control study using three-dimensional computed tomography and magnetic resonance imaging","volume":"94","author":"Hart","year":"2012","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2018.02.011_bib10","doi-asserted-by":"crossref","first-page":"1554","DOI":"10.2106\/JBJS.L.00716","article-title":"High prevalence of pseudotumors in patients with a Birmingham Hip Resurfacing prosthesis: a prospective cohort study of one hundred and twenty-nine patients","volume":"95","author":"Bisschop","year":"2013","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2018.02.011_bib11","doi-asserted-by":"crossref","first-page":"1895","DOI":"10.1007\/s11999-011-2201-7","article-title":"Pseudotumors are common in well-positioned low-wearing metal-on-metal hips","volume":"470","author":"Matthies","year":"2012","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2018.02.011_bib12","doi-asserted-by":"crossref","first-page":"1501","DOI":"10.1302\/0301-620X.92B11.24504","article-title":"Early failure of the Ultima metal-on-metal total hip replacement in the presence of normal plain radiographs 1","volume":"92","author":"Donell","year":"2010","journal-title":"J\u00a0Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2018.02.011_bib13","doi-asserted-by":"crossref","first-page":"848","DOI":"10.1148\/radiol.12120852","article-title":"Metal-on-metal total hip arthroplasty: do symptoms correlate with MR imaging findings?","volume":"265","author":"Chang","year":"2012","journal-title":"Radiology"},{"key":"10.1016\/j.arth.2018.02.011_bib14","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1007\/s11999-013-3222-1","article-title":"High frequency of adverse local tissue reactions in asymptomatic patients with metal-on-metal THA","volume":"472","author":"Fehring","year":"2014","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2018.02.011_bib15","doi-asserted-by":"crossref","first-page":"2239","DOI":"10.1016\/j.arth.2014.04.030","article-title":"Is ultrasound screening reliable for adverse local tissue reaction after hip arthroplasty?","volume":"29","author":"Nishii","year":"2014","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2018.02.011_bib16","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1007\/s11999-014-3824-2","article-title":"What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA?","volume":"473","author":"Bayley","year":"2015","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2018.02.011_bib17","doi-asserted-by":"crossref","first-page":"549","DOI":"10.3109\/17453674.2013.859419","article-title":"Adverse reaction to metal debris after ReCap-M2A-Magnum large-diameter-head metal-on-metal total hip arthroplasty 1","volume":"84","author":"Mokka","year":"2013","journal-title":"Acta Orthop"},{"key":"10.1016\/j.arth.2018.02.011_bib18","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1007\/s12306-014-0344-x","article-title":"Metal-on-metal hip resurfacing: correlation between clinical and radiological assessment, metal ions and ultrasound findings","volume":"99","author":"Scaglione","year":"2015","journal-title":"Musculoskelet Surg"},{"key":"10.1016\/j.arth.2018.02.011_bib19","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/j.arth.2010.05.030","article-title":"\u201cAsymptomatic\u201d pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study","volume":"26","author":"Kwon","year":"2011","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2018.02.011_bib20","doi-asserted-by":"crossref","first-page":"1175","DOI":"10.1302\/0301-620X.97B9.35247","article-title":"Similar incidence of periprosthetic fluid collections after ceramic-on-polyethylene total hip arthroplasties and metal-on-metal resurfacing arthroplasties: results of a screening metal artefact reduction sequence-MRI study","volume":"97-b","author":"Bisseling","year":"2015","journal-title":"Bone Joint J"},{"key":"10.1016\/j.arth.2018.02.011_bib21","doi-asserted-by":"crossref","first-page":"437","DOI":"10.3109\/17453674.2013.823590","article-title":"The absence of a metal-on-metal bearing does not preclude the formation of a destructive pseudotumor in the hip\u2013a case report","volume":"84","author":"Bisseling","year":"2013","journal-title":"Acta Orthop"},{"key":"10.1016\/j.arth.2018.02.011_bib22","doi-asserted-by":"crossref","first-page":"e666","DOI":"10.3928\/01477447-20130426-33","article-title":"Pseudotumor associated with metal-on-polyethylene total hip arthroplasty","volume":"36","author":"Scully","year":"2013","journal-title":"Orthopedics"},{"key":"10.1016\/j.arth.2018.02.011_bib23","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1016\/j.crad.2011.02.002","article-title":"MRI of asymptomatic patients with metal-on-metal and polyethylene-on-metal total hip arthroplasties","volume":"66","author":"Mistry","year":"2011","journal-title":"Clin Radiol"},{"issue":"Suppl 1","key":"10.1016\/j.arth.2018.02.011_bib24","first-page":"S47","article-title":"Adverse soft-tissue reactions around non-metal-on-metal total hip arthroplasty - a systematic review of the literature","volume":"69","author":"Carli","year":"2011","journal-title":"Bull NYU Hosp Joint Dis"},{"key":"10.1016\/j.arth.2018.02.011_bib25","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1007\/s00256-015-2264-8","article-title":"No association between pseudotumors, high serum metal-ion levels and metal hypersensitivity in large-head metal-on-metal total hip arthroplasty at 5-7-year follow-up","volume":"45","author":"Hjorth","year":"2016","journal-title":"Skeletal Radiology"},{"key":"10.1016\/j.arth.2018.02.011_bib26","doi-asserted-by":"crossref","first-page":"1894","DOI":"10.1016\/j.arth.2016.12.029","article-title":"Preparation of the femoral bone cavity for cementless stems: broaching vs compaction. A five-year randomized Radiostereometric analysis and dual energy x-ray absorption study","volume":"32","author":"Hjorth","year":"2017","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2018.02.011_bib27","doi-asserted-by":"crossref","first-page":"3412","DOI":"10.1016\/j.arth.2017.05.034","article-title":"Equal primary fixation of resurfacing stem, but Inferior cup fixation with Anterolateral vs posterior surgical approach. A 2-year blinded randomized Radiostereometric and dual-energy x-ray absorptiometry study of metal-on-metal hip resurfacing arthroplasty","volume":"32","author":"Hjorth","year":"2017","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2018.02.011_bib28","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1080\/17453674.2016.1244958","article-title":"Preparation of the femoral bone cavity in cementless stems: broaching versus compaction","volume":"87","author":"Hjorth","year":"2016","journal-title":"Acta Orthopaedica"},{"key":"10.1016\/j.arth.2018.02.011_bib29","first-page":"319","article-title":"The hip resurfacing handbook a practical guide use management modern hip resurfacing","volume":"vol. 47","author":"De Smet","year":"2013"},{"key":"10.1016\/j.arth.2018.02.011_bib30","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1007\/s00256-013-1755-8","article-title":"Comparison of different pseudotumor grading systems in a single cohort of metal-on-metal hip arthroplasty patients","volume":"43","author":"van der Weegen","year":"2014","journal-title":"Skeletal Radiol"},{"key":"10.1016\/j.arth.2018.02.011_bib31","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1007\/s00256-010-1000-7","article-title":"Grading the severity of soft tissue changes associated with metal-on-metal hip replacements: reliability of an MR grading system","volume":"40","author":"Anderson","year":"2011","journal-title":"Skeletal Radiol"},{"issue":"3","key":"10.1016\/j.arth.2018.02.011_bib32","doi-asserted-by":"crossref","first-page":"1312","DOI":"10.1007\/s00330-016-4455-7","article-title":"MR imaging of soft tissue alterations after total hip arthroplasty: comparison of classic surgical approaches","volume":"27","author":"Agten","year":"2017","journal-title":"Eur Radiol"},{"key":"10.1016\/j.arth.2018.02.011_bib33","first-page":"20","article-title":"Radiological demarcation of cemented sockets in total hip replacement 1","volume":"121","author":"DeLee","year":"1976","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2018.02.011_bib34","first-page":"17","article-title":"\u201cModes of failure\u201d of cemented stem-type femoral components: a radiographic analysis of loosening 38","author":"Gruen","year":"1979","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2018.02.011_bib35","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1302\/0301-620X.86B2.14338","article-title":"Preservation of the bone mineral density of the femur after surface replacement of the hip 3","volume":"86","author":"Kishida","year":"2004","journal-title":"J\u00a0Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2018.02.011_bib36","doi-asserted-by":"crossref","first-page":"1629","DOI":"10.2106\/00004623-197355080-00006","article-title":"Ectopic ossification following total hip replacement. Incidence and a method of classification 1","volume":"55","author":"Brooker","year":"1973","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2018.02.011_bib37","first-page":"303","article-title":"Measurement of polyethylene wear in metal-backed acetabular cups. I. Three-dimensional technique","author":"Devane","year":"1995","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2018.02.011_bib38","first-page":"317","article-title":"Measurement of polyethylene wear in metal-backed acetabular cups. II. Clinical application","author":"Devane","year":"1995","journal-title":"Clin Orthop Relat Res"},{"issue":"8 Suppl 3","key":"10.1016\/j.arth.2018.02.011_bib39","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.arth.2004.09.009","article-title":"A\u00a0consensus paper on metal ions in metal-on-metal hip arthroplasties","volume":"19","author":"MacDonald","year":"2004","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2018.02.011_bib40","doi-asserted-by":"crossref","first-page":"737","DOI":"10.2106\/00004623-196951040-00012","article-title":"Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation","volume":"51","author":"Harris","year":"1969","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2018.02.011_bib41","doi-asserted-by":"crossref","first-page":"1010","DOI":"10.1302\/0301-620X.89B8.19424","article-title":"The use of the Oxford hip and knee scores 148","volume":"89","author":"Murray","year":"2007","journal-title":"J\u00a0Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2018.02.011_bib42","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1136\/bjsm.2010.080937","article-title":"The Copenhagen hip and Groin outcome score (HAGOS): development and validation according to the COSMIN checklist","volume":"45","author":"Thorborg","year":"2011","journal-title":"Br J Sports Med"},{"key":"10.1016\/j.arth.2018.02.011_bib43","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1007\/s00256-011-1329-6","article-title":"A\u00a0MRI classification of periprosthetic soft tissue masses (pseudotumours) associated with metal-on-metal resurfacing hip arthroplasty","volume":"41","author":"Hauptfleisch","year":"2012","journal-title":"Skeletal Radiol"},{"key":"10.1016\/j.arth.2018.02.011_bib44","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.ocl.2011.01.005","article-title":"A\u00a0prospective metal ion study of large-head metal-on-metal bearing: a matched-pair analysis of hip resurfacing versus total hip replacement 5","volume":"42","author":"Beaule","year":"2011","journal-title":"Orthop Clin North Am"},{"key":"10.1016\/j.arth.2018.02.011_bib45","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1007\/s11999-009-1029-x","article-title":"The John Charnley Award: metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial 43","volume":"468","author":"Garbuz","year":"2010","journal-title":"Clin Orthop Relat Res"},{"issue":"Suppl 2","key":"10.1016\/j.arth.2018.02.011_bib46","doi-asserted-by":"crossref","first-page":"128","DOI":"10.2106\/JBJS.J.01885","article-title":"Comparison of whole-blood metal ion levels in four types of metal-on-metal large-diameter femoral head total hip arthroplasty: the potential influence of the adapter sleeve 21","volume":"93","author":"Lavigne","year":"2011","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2018.02.011_bib47","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1177\/1457496913495345","article-title":"Hip resurfacing arthroplasty versus large-diameter head metal-on-metal total hip arthroplasty: comparison of three designs from the Finnish Arthroplasty Register","volume":"103","author":"Junnila","year":"2014","journal-title":"Scand J Surg"},{"key":"10.1016\/j.arth.2018.02.011_bib48","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1016\/j.otsr.2016.08.020","article-title":"Does a titanium sleeve reduce the frequency of pseudotumors in metal-on-metal total hip arthroplasty at 5-7years follow-up?","volume":"102","author":"Hjorth","year":"2016","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.arth.2018.02.011_bib49","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.2106\/JBJS.K.01352","article-title":"Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty","volume":"94","author":"Cooper","year":"2012","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2018.02.011_bib50","doi-asserted-by":"crossref","first-page":"1024","DOI":"10.1302\/0301-620X.97B8.34682","article-title":"Adverse local tissue reactions in metal-on-polyethylene total hip arthroplasty due to trunnion corrosion: the risk of misdiagnosis","volume":"97-b","author":"Whitehouse","year":"2015","journal-title":"Bone Joint J"},{"key":"10.1016\/j.arth.2018.02.011_bib51","doi-asserted-by":"crossref","first-page":"1238","DOI":"10.2106\/00004623-198870080-00017","article-title":"Formation of a fulminant soft-tissue pseudotumor after uncemented hip arthroplasty. A case report","volume":"70","author":"Svensson","year":"1988","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2018.02.011_bib52","doi-asserted-by":"crossref","first-page":"e606","DOI":"10.3928\/01477447-20130426-23","article-title":"Prevalence of adverse reactions to metal debris following metal-on-metal THA","volume":"36","author":"Hasegawa","year":"2013","journal-title":"Orthopedics"},{"key":"10.1016\/j.arth.2018.02.011_bib53","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1016\/j.arth.2014.12.005","article-title":"Usefulness of ultrasonography for detection of pseudotumors after metal-on-metal total hip arthroplasty","volume":"30","author":"Muraoka","year":"2015","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2018.02.011_bib54","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1186\/s12891-016-1317-z","article-title":"Factors associated with symptomatic pseudotumors following metal-on-metal total hip arthroplasty","volume":"17","author":"Hasegawa","year":"2016","journal-title":"BMC Musculoskelet Disord"},{"key":"10.1016\/j.arth.2018.02.011_bib55","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1016\/j.arth.2015.07.011","article-title":"Prevalence of pseudotumor in patients after metal-on-metal hip arthroplasty evaluated with metal ion analysis and MARS-MRI","volume":"31","author":"Sutphen","year":"2016","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2018.02.011_bib56","doi-asserted-by":"crossref","first-page":"3814","DOI":"10.1007\/s11999-013-2944-4","article-title":"The natural history of inflammatory pseudotumors in asymptomatic patients after metal-on-metal hip arthroplasty 4","volume":"471","author":"Almousa","year":"2013","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2018.02.011_bib57","doi-asserted-by":"crossref","first-page":"522","DOI":"10.5301\/hipint.5000387","article-title":"What is the natural history of asymptomatic pseudotumours in metal-on-metal hip resurfacing patients?","volume":"26","author":"Matharu","year":"2016","journal-title":"Hip Int"},{"key":"10.1016\/j.arth.2018.02.011_bib58","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.1007\/s00264-014-2300-7","article-title":"Repeated metal ion measurements in patients with high risk metal-on-metal hip replacement","volume":"38","author":"Reito","year":"2014","journal-title":"Int Orthop"}],"container-title":["The Journal of Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540318301402?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540318301402?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,6,14]],"date-time":"2018-06-14T23:58:37Z","timestamp":1529020717000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0883540318301402"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7]]},"references-count":58,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2018,7]]}},"alternative-id":["S0883540318301402"],"URL":"https:\/\/doi.org\/10.1016\/j.arth.2018.02.011","relation":{},"ISSN":["0883-5403"],"issn-type":[{"value":"0883-5403","type":"print"}],"subject":[],"published":{"date-parts":[[2018,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Higher Prevalence of Mixed or Solid Pseudotumors in Metal-on-Polyethylene Total Hip Arthroplasty Compared With Metal-on-Metal Total Hip Arthroplasty and Resurfacing Hip Arthroplasty","name":"articletitle","label":"Article Title"},{"value":"The Journal of Arthroplasty","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arth.2018.02.011","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}