{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T06:22:30Z","timestamp":1780467750168,"version":"3.54.1"},"reference-count":34,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2019,10,1]],"date-time":"2019-10-01T00:00:00Z","timestamp":1569888000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,10,1]],"date-time":"2019-10-01T00:00:00Z","timestamp":1569888000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100000009","name":"Foundation for the National Institutes of Health","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000009","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["arthroplastyjournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Arthroplasty"],"published-print":{"date-parts":[[2019,10]]},"DOI":"10.1016\/j.arth.2019.05.030","type":"journal-article","created":{"date-parts":[[2019,5,24]],"date-time":"2019-05-24T03:00:46Z","timestamp":1558666846000},"page":"2479-2486","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":17,"title":["Is There Material Loss at the Conical Junctions of Modular Components for Total Knee Arthroplasty?"],"prefix":"10.1016","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2114-0358","authenticated-orcid":false,"given":"Hannah","family":"Spece","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard J.","family":"Underwood","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Doruk","family":"Baykal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lawrence E.","family":"Eiselstein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel A.","family":"Torelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregg R.","family":"Klein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4122-7976","authenticated-orcid":false,"given":"Gwo-Chin","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven M.","family":"Kurtz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.arth.2019.05.030_bib1","doi-asserted-by":"crossref","first-page":"3652","DOI":"10.1007\/s11999-014-3746-z","article-title":"What is the trouble with trunnions?","volume":"472","author":"Esposito","year":"2014","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2019.05.030_bib2","doi-asserted-by":"crossref","first-page":"758123","DOI":"10.1155\/2015\/758123","article-title":"Head-neck taper corrosion in hip arthroplasty","volume":"2015","author":"Hussenbocus","year":"2015","journal-title":"Biomed Res Int"},{"key":"10.1016\/j.arth.2019.05.030_bib3","doi-asserted-by":"crossref","first-page":"3674","DOI":"10.1007\/s11999-014-3652-4","article-title":"The surgical options and clinical evidence for treatment of wear or corrosion occurring with THA or TKA","volume":"472","author":"Engh","year":"2014","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2019.05.030_bib4","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1016\/j.arth.2012.04.005","article-title":"Adverse local tissue response lesion of the knee associated with Morse taper corrosion","volume":"28","author":"McMaster","year":"2013","journal-title":"J\u00a0Arthroplasty"},{"issue":"9 Suppl","key":"10.1016\/j.arth.2019.05.030_bib5","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/j.arth.2013.12.034","article-title":"Mechanically assisted taper corrosion in modular TKA","volume":"29","author":"Arnholt","year":"2014","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2019.05.030_bib6","doi-asserted-by":"crossref","first-page":"8046","DOI":"10.1016\/j.actbio.2013.05.005","article-title":"Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms","volume":"9","author":"Gallo","year":"2013","journal-title":"Acta Biomater"},{"key":"10.1016\/j.arth.2019.05.030_bib7","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1302\/0301-620X.94B8.28289","article-title":"The role of the design of tibial components and stems in knee replacement","volume":"94","author":"Scott","year":"2012","journal-title":"J\u00a0Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2019.05.030_bib8","first-page":"1487","article-title":"Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002","volume":"87","author":"Kurtz","year":"2005","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2019.05.030_bib9","doi-asserted-by":"crossref","first-page":"1677","DOI":"10.1002\/jor.22431","article-title":"Material loss at the taper junction of retrieved large head metal-on-metal total hip replacements","volume":"31","author":"Matthies","year":"2013","journal-title":"J\u00a0Orthop Res"},{"key":"10.1016\/j.arth.2019.05.030_bib10","doi-asserted-by":"crossref","first-page":"1533","DOI":"10.1002\/jbm.820271210","article-title":"In\u00a0vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling","volume":"27","author":"Gilbert","year":"1993","journal-title":"J\u00a0Biomed Mater Res"},{"key":"10.1016\/j.arth.2019.05.030_bib11","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1007\/s11999-013-3115-3","article-title":"Taper design affects failure of large-head metal-on-metal total hip replacements","volume":"472","author":"Nassif","year":"2014","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2019.05.030_bib12","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1097\/00003086-200208000-00018","article-title":"A\u00a0multicenter retrieval study of the taper interfaces of modular hip prostheses","author":"Goldberg","year":"2002","journal-title":"Clin Orthop Relat Res"},{"issue":"8 Suppl","key":"10.1016\/j.arth.2019.05.030_bib13","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.arth.2013.05.040","article-title":"Is increased modularity associated with increased fretting and corrosion damage in metal-on-metal total hip arthroplasty devices? A retrieval study","volume":"28","author":"Higgs","year":"2013","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2019.05.030_bib14","doi-asserted-by":"crossref","first-page":"817257","DOI":"10.1155\/2014\/817257","article-title":"Serum metal ion concentrations in paediatric patients following total knee arthroplasty using megaprostheses","volume":"2014","author":"Friesenbichler","year":"2014","journal-title":"Biomed Res Int"},{"key":"10.1016\/j.arth.2019.05.030_bib15","first-page":"651279","article-title":"Clinical outcomes of tibial components with modular stems used in primary TKA","volume":"2014","author":"Durig","year":"2014","journal-title":"Adv Orthop"},{"key":"10.1016\/j.arth.2019.05.030_bib16","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1302\/2046-3758.14.2000047","article-title":"Taper junction failure in large-diameter metal-on-metal bearings","volume":"1","author":"Langton","year":"2012","journal-title":"Bone Joint Res"},{"key":"10.1016\/j.arth.2019.05.030_bib17","doi-asserted-by":"crossref","first-page":"1304","DOI":"10.1302\/0301-620X.99B10.BJJ-2016-1005.R1","article-title":"A\u00a0comparison study of stem taper material loss at similar and mixed metal head-neck taper junctions","volume":"99-B","author":"Langton","year":"2017","journal-title":"Bone Joint J"},{"key":"10.1016\/j.arth.2019.05.030_bib18","doi-asserted-by":"crossref","first-page":"1654","DOI":"10.1016\/j.arth.2016.11.056","article-title":"Elevated intra-articular cobalt and chromium levels in mechanically assisted crevice corrosion in metal-on-polyethylene total hip arthroplasty","volume":"32","author":"McGrory","year":"2017","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2019.05.030_bib19","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.1007\/s00256-014-1860-3","article-title":"Severe metallosis following total knee arthroplasty: a case report and review of radiographic signs","volume":"43","author":"Helito","year":"2014","journal-title":"Skeletal Radiol"},{"key":"10.1016\/j.arth.2019.05.030_bib20","doi-asserted-by":"crossref","DOI":"10.1136\/bcr-2013-202801","article-title":"Metallosis in a total knee arthroplasty","volume":"2014","author":"Vivegananthan","year":"2014","journal-title":"BMJ Case Rep"},{"key":"10.1016\/j.arth.2019.05.030_bib21","first-page":"12","article-title":"Implications of metallic corrosion in total knee arthroplasty","author":"Wapner","year":"1991","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2019.05.030_bib22","doi-asserted-by":"crossref","first-page":"2503","DOI":"10.1007\/s00264-017-3528-9","article-title":"Metallic ion release after knee prosthesis implantation: a prospective study","volume":"41","author":"Lons","year":"2017","journal-title":"Int Orthop"},{"key":"10.1016\/j.arth.2019.05.030_bib23","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1097\/BLO.0b013e31806450ef","article-title":"Serum metal ion exposure after total knee arthroplasty","volume":"461","author":"Luetzner","year":"2007","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2019.05.030_bib24","doi-asserted-by":"crossref","first-page":"634","DOI":"10.1302\/0301-620X.92B5.23452","article-title":"The potential role of metal ion release as a marker of loosening in patients with total knee replacement: a cohort study","volume":"92","author":"Savarino","year":"2010","journal-title":"J\u00a0Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2019.05.030_bib25","doi-asserted-by":"crossref","first-page":"2279","DOI":"10.1016\/j.arth.2017.02.047","article-title":"Assessment of corrosion, fretting, and material loss of retrieved modular total knee arthroplasties","volume":"32","author":"Martin","year":"2017","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2019.05.030_bib26","series-title":"Metal-on-metal total hip replacement devices, STP 1560","first-page":"146","article-title":"Method of characterizing fretting and corrosion at the various taper connections of retrieved modular components from metal-on-metal total hip arthroplasty","author":"Higgs","year":"2013"},{"key":"10.1016\/j.arth.2019.05.030_bib27","series-title":"Standard guide for characterization of material loss from conical taper junctions in total joint prostheses","year":"2016"},{"key":"10.1016\/j.arth.2019.05.030_bib28","doi-asserted-by":"crossref","first-page":"485975","DOI":"10.1155\/2015\/485975","article-title":"Titanium-nitride coating of orthopaedic implants: a review of the literature","volume":"2015","author":"van Hove","year":"2015","journal-title":"Biomed Res Int"},{"key":"10.1016\/j.arth.2019.05.030_bib29","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1007\/s11420-016-9517-5","article-title":"Characterization of femoral head taper corrosion features using a 22-year retrieval database","volume":"13","author":"Cartner","year":"2017","journal-title":"HSS J"},{"key":"10.1016\/j.arth.2019.05.030_bib30","doi-asserted-by":"crossref","first-page":"3270","DOI":"10.1007\/s11999-013-3096-2","article-title":"Do ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study","volume":"471","author":"Kurtz","year":"2013","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2019.05.030_bib31","doi-asserted-by":"crossref","first-page":"1313","DOI":"10.1016\/j.arth.2013.12.003","article-title":"The reliability of a scoring system for corrosion and fretting, and its relationship to material loss of tapered, modular junctions of retrieved hip implants","volume":"29","author":"Hothi","year":"2014","journal-title":"J\u00a0Arthroplasty"},{"key":"10.1016\/j.arth.2019.05.030_bib32","doi-asserted-by":"crossref","first-page":"985","DOI":"10.1007\/s11999-015-4683-1","article-title":"Ceramic heads decrease metal release caused by head-taper fretting and corrosion","volume":"474","author":"Kocagoz","year":"2016","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2019.05.030_bib33","doi-asserted-by":"crossref","first-page":"1634","DOI":"10.1016\/j.jbiomech.2014.02.035","article-title":"Total hip arthroplasty head-neck contact mechanics: a stochastic investigation of key parameters","volume":"47","author":"Donaldson","year":"2014","journal-title":"J\u00a0Biomech"},{"key":"10.1016\/j.arth.2019.05.030_bib34","doi-asserted-by":"crossref","first-page":"2301","DOI":"10.1016\/j.arth.2017.02.016","article-title":"Retrieval analysis of neck-stem coupling in modular hip prostheses","volume":"32","author":"Su","year":"2017","journal-title":"J\u00a0Arthroplasty"}],"container-title":["The Journal of Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540319305133?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540319305133?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T18:26:07Z","timestamp":1760120767000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0883540319305133"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10]]},"references-count":34,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2019,10]]}},"alternative-id":["S0883540319305133"],"URL":"https:\/\/doi.org\/10.1016\/j.arth.2019.05.030","relation":{},"ISSN":["0883-5403"],"issn-type":[{"value":"0883-5403","type":"print"}],"subject":[],"published":{"date-parts":[[2019,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Is There Material Loss at the Conical Junctions of Modular Components for Total Knee Arthroplasty?","name":"articletitle","label":"Article Title"},{"value":"The Journal of Arthroplasty","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arth.2019.05.030","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}