{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T19:26:21Z","timestamp":1787167581873,"version":"build-2736575974"},"reference-count":39,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"funder":[{"DOI":"10.13039\/501100004332","name":"Seoul National University Hospital","doi-asserted-by":"publisher","award":["04\\u20132022-0310"],"award-info":[{"award-number":["04\\u20132022-0310"]}],"id":[{"id":"10.13039\/501100004332","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004332","name":"Seoul National University Hospital","doi-asserted-by":"publisher","award":["06\\u20132003-0630"],"award-info":[{"award-number":["06\\u20132003-0630"]}],"id":[{"id":"10.13039\/501100004332","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["arthroplastyjournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Arthroplasty"],"published-print":{"date-parts":[[2025,4]]},"DOI":"10.1016\/j.arth.2024.10.009","type":"journal-article","created":{"date-parts":[[2024,10,16]],"date-time":"2024-10-16T06:42:34Z","timestamp":1729060954000},"page":"992-998","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":7,"title":["Quarter Century Outcomes of Alumina Ceramic-on-Ceramic Total Hip Arthroplasty"],"prefix":"10.1016","volume":"40","author":[{"given":"Hong Seok","family":"Kim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6304-0101","authenticated-orcid":false,"given":"Jeong Joon","family":"Yoo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.arth.2024.10.009_bib1","doi-asserted-by":"crossref","first-page":"1508","DOI":"10.1016\/S0140-6736(07)60457-7","article-title":"The operation of the century: total hip replacement","volume":"370","author":"Learmonth","year":"2007","journal-title":"Lancet"},{"key":"10.1016\/j.arth.2024.10.009_bib2","doi-asserted-by":"crossref","first-page":"780","DOI":"10.2106\/00004623-200704000-00012","article-title":"Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030","volume":"89","author":"Kurtz","year":"2007","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2024.10.009_bib3","doi-asserted-by":"crossref","DOI":"10.1016\/j.otsr.2022.103457","article-title":"What have we learned from 20 years of using highly crosslinked PE in total hip arthroplasty?","volume":"109","author":"Langlois","year":"2023","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.arth.2024.10.009_bib4","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1016\/j.jor.2021.04.004","article-title":"Ultra-high molecular weight polyethylene (UHMWPE) for hip and knee arthroplasty: the present and the future","volume":"25","author":"Bistolfi","year":"2021","journal-title":"J Orthop"},{"key":"10.1016\/j.arth.2024.10.009_bib5","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1007\/s00402-022-04357-w","article-title":"Evolution of total hip arthroplasty in patients younger than 30 years of age: a systematic review and meta-analysis","volume":"143","author":"Konopitski","year":"2023","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.arth.2024.10.009_bib6","doi-asserted-by":"crossref","first-page":"1381","DOI":"10.1007\/s00264-023-06086-0","article-title":"Outcome and complication rate of total hip arthroplasty in patients younger than twenty years: which bearing surface should be used?","volume":"48","author":"Kang","year":"2024","journal-title":"Int Orthop"},{"key":"10.1016\/j.arth.2024.10.009_bib7","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1016\/j.arth.2021.11.028","article-title":"Long-term results of alumina ceramic-on-ceramic bearings in cementless total hip arthroplasty: a 20-year minimum follow-up","volume":"37","author":"Xu","year":"2022","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2024.10.009_bib8","doi-asserted-by":"crossref","first-page":"3507","DOI":"10.1016\/j.arth.2021.05.038","article-title":"Survivorship of ceramic-on-ceramic total hip arthroplasty with metal-backed acetabular liners at 10 years","volume":"36","author":"Wagner","year":"2021","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2024.10.009_bib9","doi-asserted-by":"crossref","first-page":"S232","DOI":"10.1016\/j.arth.2019.01.057","article-title":"Results of 200 consecutive ceramic-on-ceramic cementless hip arthroplasties in patients up to 50 years of age: a 5-24 years of follow-up study","volume":"34","author":"Solarino","year":"2019","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2024.10.009_bib10","doi-asserted-by":"crossref","first-page":"2520","DOI":"10.1016\/j.arth.2016.03.058","article-title":"Long-term results of third-generation ceramic-on-ceramic bearing cementless total hip arthroplasty in young patients","volume":"31","author":"Kim","year":"2016","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2024.10.009_bib11","doi-asserted-by":"crossref","first-page":"530","DOI":"10.2106\/00004623-200503000-00008","article-title":"Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study","volume":"87","author":"Yoo","year":"2005","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2024.10.009_bib12","doi-asserted-by":"crossref","first-page":"1715","DOI":"10.2106\/JBJS.I.01019","article-title":"Alumina-on-alumina total hip arthroplasty: a concise follow-up, at a minimum of ten years, of a previous report","volume":"92","author":"Lee","year":"2010","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2024.10.009_bib13","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1053\/jars.2000.7683","article-title":"Prospective analysis of hip arthroscopy with 2-year follow-up","volume":"16","author":"Byrd","year":"2000","journal-title":"Arthroscopy"},{"key":"10.1016\/j.arth.2024.10.009_bib14","first-page":"1833","article-title":"Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee","volume":"15","author":"Bellamy","year":"1988","journal-title":"J Rheumatol"},{"key":"10.1016\/j.arth.2024.10.009_bib15","first-page":"89","article-title":"Porous-coated total hip replacement","author":"Engh","year":"1994","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2024.10.009_bib16","doi-asserted-by":"crossref","first-page":"48","DOI":"10.2106\/00004623-198567010-00007","article-title":"Radiographic analysis of a low-modulus titanium-alloy femoral total hip component. Two to six-year follow-up","volume":"67","author":"Sarmiento","year":"1985","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2024.10.009_bib17","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1302\/0301-620X.80B4.0800585","article-title":"Osteolysis after Charnley primary low-friction arthroplasty. A comparison of two matched paired groups","volume":"80","author":"Joshi","year":"1998","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2024.10.009_bib18","doi-asserted-by":"crossref","first-page":"554","DOI":"10.2106\/00004623-199304000-00010","article-title":"Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement","volume":"75","author":"Martell","year":"1993","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2024.10.009_bib19","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1097\/00003086-197906000-00002","article-title":"\u201cModes of failure\u201d of cemented stem-type femoral components: a radiographic analysis of loosening","author":"Gruen","year":"1979","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2024.10.009_bib20","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1097\/00003086-197611000-00003","article-title":"Radiological demarcation of cemented sockets in total hip replacement","author":"DeLee","year":"1976","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2024.10.009_bib21","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.2106\/00004623-199072070-00011","article-title":"Endosteal erosion in association with stable uncemented femoral components","volume":"72","author":"Maloney","year":"1990","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2024.10.009_bib22","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/j.arth.2003.10.016","article-title":"A simplified method to determine acetabular cup anteversion from plain radiographs","volume":"19","author":"Widmer","year":"2004","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2024.10.009_bib23","article-title":"Computed tomography evaluation of alumina ceramic-on-ceramic total hip arthroplasty with more than 20 years of follow-up: is a follow-up computed tomography scan necessary?","author":"Ko","year":"2024","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2024.10.009_bib24","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1302\/0301-620X.75B2.8444933","article-title":"Survival analysis in joint replacement surgery","volume":"75","author":"Carr","year":"1993","journal-title":"J Bone Joint Surg Br"},{"key":"10.1016\/j.arth.2024.10.009_bib25","doi-asserted-by":"crossref","first-page":"2864","DOI":"10.1111\/os.13889","article-title":"Ceramic-on-Ceramic or metal-on-polyethylene: the bearing of choice after ceramic component fracture in total hip arthroplasty along with concise follow-up of the previous cohort","volume":"15","author":"Kim","year":"2023","journal-title":"Orthop Surg"},{"key":"10.1016\/j.arth.2024.10.009_bib26","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1016\/j.arth.2015.08.039","article-title":"Bearing change to metal-on-polyethylene for ceramic bearing fracture in total hip arthroplasty; does it work?","volume":"31","author":"Lee","year":"2016","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2024.10.009_bib27","doi-asserted-by":"crossref","first-page":"736","DOI":"10.1097\/CORR.0000000000001472","article-title":"Squeaking is common and increases over time among patients with long-term follow-up after ceramic-on-ceramic THA","volume":"479","author":"Taniguchi","year":"2021","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2024.10.009_bib28","doi-asserted-by":"crossref","first-page":"1254","DOI":"10.1097\/CORR.0000000000001272","article-title":"What is the frequency of fracture of ceramic components in THA? Results from the norwegian arthroplasty register from 1997 to 2017","volume":"478","author":"Hallan","year":"2020","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2024.10.009_bib29","doi-asserted-by":"crossref","first-page":"329","DOI":"10.2106\/JBJS.F.01489","article-title":"Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty","volume":"90","author":"Koo","year":"2008","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2024.10.009_bib30","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1097\/00003086-199607000-00021","article-title":"Ceramic femoral head fractures in total hip arthroplasty","author":"Fritsch","year":"1996","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2024.10.009_bib31","doi-asserted-by":"crossref","first-page":"1012","DOI":"10.1302\/0301-620X.99B8.BJJ-2017-0019.R1","article-title":"Ceramic-on-ceramic bearing fractures in total hip arthroplasty: an analysis of data from the National Joint Registry","volume":"99-B","author":"Howard","year":"2017","journal-title":"Bone Joint J"},{"key":"10.1016\/j.arth.2024.10.009_bib32","doi-asserted-by":"crossref","first-page":"350","DOI":"10.3390\/ma13020350","article-title":"Burst strength of BIOLOX((R))delta femoral heads and its dependence on low-temperature environmental degradation","volume":"13","author":"Tateiwa","year":"2020","journal-title":"Materials"},{"key":"10.1016\/j.arth.2024.10.009_bib33","doi-asserted-by":"crossref","DOI":"10.2106\/JBJS.K.00589","article-title":"Revision of ceramic hip replacements for fracture of a ceramic component: AAOS exhibit selection","volume":"93","author":"Traina","year":"2011","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2024.10.009_bib34","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1097\/CORR.0000000000002022","article-title":"High risk of neck-liner impingement and notching observed with thick femoral neck implants in ceramic-on-ceramic THA","volume":"480","author":"Kim","year":"2022","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2024.10.009_bib35","article-title":"Ceramic-on-Ceramic total hip arthroplasty: I can hear you","volume":"23","author":"Shang","year":"2023","journal-title":"Arthroplast Today"},{"key":"10.1016\/j.arth.2024.10.009_bib36","doi-asserted-by":"crossref","first-page":"2536","DOI":"10.1016\/j.arth.2024.05.021","article-title":"Bearing-related complications of total hip arthroplasty using fourth-generation ceramic-on-ceramic articulations: does articular noise increase over time?","volume":"39","author":"Park","year":"2024","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2024.10.009_bib37","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1016\/j.arth.2023.08.027","article-title":"Factors influencing noise following primary ceramic-on-ceramic total hip arthroplasty","volume":"39","author":"Zhang","year":"2024","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2024.10.009_bib38","doi-asserted-by":"crossref","first-page":"139","DOI":"10.2106\/JBJS.20.00354","article-title":"Impingement between the metal stem and the ceramic liner in total hip arthroplasty: the neck is not the only place where impingement occurs","volume":"103","author":"Lee","year":"2021","journal-title":"J Bone Joint Surg Am"},{"issue":"Suppl 2","key":"10.1016\/j.arth.2024.10.009_bib39","doi-asserted-by":"crossref","first-page":"68","DOI":"10.2106\/JBJS.20.00720","article-title":"Third-generation ceramic-on-ceramic total hip arthroplasty in patients with osteonecrosis of the femoral head: a 10- to 16-year follow-up study","volume":"104","author":"Kim","year":"2022","journal-title":"J Bone Joint Surg Am"}],"container-title":["The Journal of Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540324010222?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540324010222?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,5,11]],"date-time":"2026-05-11T23:53:33Z","timestamp":1778543613000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0883540324010222"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":39,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,4]]}},"alternative-id":["S0883540324010222"],"URL":"https:\/\/doi.org\/10.1016\/j.arth.2024.10.009","relation":{},"ISSN":["0883-5403"],"issn-type":[{"value":"0883-5403","type":"print"}],"subject":[],"published":{"date-parts":[[2025,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Quarter Century Outcomes of Alumina Ceramic-on-Ceramic Total Hip Arthroplasty","name":"articletitle","label":"Article Title"},{"value":"The Journal of Arthroplasty","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arth.2024.10.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}