{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,22]],"date-time":"2026-08-22T10:27:06Z","timestamp":1787394426662,"version":"build-2736575974"},"reference-count":23,"publisher":"Elsevier BV","issue":"9","license":[{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["arthroplastyjournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Arthroplasty"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1016\/j.arth.2026.04.052","type":"journal-article","created":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T23:05:40Z","timestamp":1776899140000},"page":"S220-S227","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"S1","title":["Minimum Two-Year Survivorship of Large Femoral Heads With Titanium Sleeves in Primary Total Hip Arthroplasty: An Analysis From the American Joint Replacement Registry"],"prefix":"10.1016","volume":"41","author":[{"given":"Sanchez","family":"Marcel","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carender","family":"Chris","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zaniletti","family":"Isabella","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1693-218X","authenticated-orcid":false,"suffix":"III","given":"James I","family":"Huddleston","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hegde","family":"Vishal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.arth.2026.04.052_bib1","doi-asserted-by":"crossref","first-page":"S183","DOI":"10.1016\/j.arth.2024.01.045","article-title":"New ceramic heads with titanium sleeves on retained femoral components: results of over 500 revision total hip arthroplasties","volume":"39","author":"Roberts","year":"2024","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.04.052_bib2","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1016\/j.arth.2024.08.002","article-title":"Ceramic heads with 12\/14 titanium sleeves used on manufacturer-non-compatible retained femoral components do not lead to implant failure in revision hip arthroplasty","volume":"40","author":"Simon","year":"2025","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.04.052_bib3","doi-asserted-by":"crossref","first-page":"2887","DOI":"10.1016\/j.arth.2017.04.025","article-title":"Fretting and corrosion damage in taper adapter sleeves for ceramic heads: a retrieval Study","volume":"32","author":"MacDonald","year":"2017","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.04.052_bib4","doi-asserted-by":"crossref","first-page":"3262","DOI":"10.1007\/s11999-013-3033-4","article-title":"Long-term (20- to 25- year) results of an uncemented tapered titanium femoral component and factors affecting survivorship","volume":"471","author":"Streit","year":"2013","journal-title":"Clin Orthop"},{"key":"10.1016\/j.arth.2026.04.052_bib5","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1054\/arth.2001.17940","article-title":"Grit-blasted titanium femoral stem in cementless primary total hip arthroplasty","volume":"16","author":"Delaunay","year":"2001","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.04.052_bib6","doi-asserted-by":"crossref","first-page":"2231","DOI":"10.1016\/j.arth.2016.04.037","article-title":"Minimum 10-Year Follow-Up of cementless total hip arthroplasty using a contemporary triple-tapered titanium stem","volume":"31","author":"Carlson","year":"2016","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.04.052_bib7","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1007\/s11999-008-0568-x","article-title":"Survivorship of 2000 tapered titanium porous plasma-sprayed femoral components","volume":"467","author":"Lombardi","year":"2009","journal-title":"Clin Orthop"},{"key":"10.1016\/j.arth.2026.04.052_bib8","doi-asserted-by":"crossref","first-page":"e1521","DOI":"10.3928\/01477447-20131120-16","article-title":"Four- to six-year Follow-up of primary THA using contemporary titanium tapered stems","volume":"36","author":"Goetz","year":"2013","journal-title":"Orthopedics"},{"key":"10.1016\/j.arth.2026.04.052_bib9","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/S0883-5403(03)00344-9","article-title":"Thirteen year results of total hip arthroplasty using a tapered titanium femoral component inserted without cement in patients with type C bone","volume":"18","author":"Reitman","year":"2003","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.04.052_bib10","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1016\/j.arth.2017.10.010","article-title":"Fretting and corrosion damage in retrieved metal-on-polyethylene modular total hip arthroplasty systems: what is the importance of femoral head size?","volume":"33","author":"Siljander","year":"2018","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.04.052_bib11","doi-asserted-by":"crossref","first-page":"1462","DOI":"10.2106\/JBJS.21.01101","article-title":"A comparison of revision rates and dislocation after primary total hip arthroplasty with 28, 32, and 36-mm femoral heads and different cup sizes: an analysis of 188,591 primary total hip arthroplasties","volume":"104","author":"Hoskins","year":"2022","journal-title":"J Bone Joint Surg Am"},{"key":"10.1016\/j.arth.2026.04.052_bib12","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.arth.2018.09.004","article-title":"Taper-Trunnion interface stress varies significantly with head size and activity","volume":"34","author":"Norman","year":"2019","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.04.052_bib13","doi-asserted-by":"crossref","first-page":"2580","DOI":"10.1016\/j.arth.2017.03.033","article-title":"Mechanical stability of the taper connection of large metal femoral heads with adapter sleeves in total hip arthroplasty analyzed using explicit finite element simulations","volume":"32","author":"Vogel","year":"2017","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.04.052_bib14","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1080\/17453674.2019.1618649","article-title":"Registry study on failure incidence in 1,127 revised hip implants with stem trunnion re-use after 10 years of follow-up: limited influence of an adapter sleeve","volume":"90","author":"Affatato","year":"2019","journal-title":"Acta Orthop"},{"key":"10.1016\/j.arth.2026.04.052_bib15","doi-asserted-by":"crossref","first-page":"S25","DOI":"10.1016\/j.otsr.2014.07.026","article-title":"Femoral head diameter considerations for primary total hip arthroplasty","volume":"101","author":"Girard","year":"2015","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.arth.2026.04.052_bib16","doi-asserted-by":"crossref","first-page":"342","DOI":"10.3109\/17453674.2013.810518","article-title":"Effect of femoral head size on risk of revision for dislocation after total hip arthroplasty: a population-based analysis of 42,379 primary procedures from the Finnish Arthroplasty Register","volume":"84","author":"Kostensalo","year":"2013","journal-title":"Acta Orthop"},{"issue":"Supple_A","key":"10.1016\/j.arth.2026.04.052_bib17","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1302\/0301-620X.96B11.34342","article-title":"Large diameter femoral heads: is bigger always better?","volume":"96- B","author":"Cooper","year":"2014","journal-title":"Bone Joint J"},{"key":"10.1016\/j.arth.2026.04.052_bib18","doi-asserted-by":"crossref","first-page":"2966","DOI":"10.1002\/jor.24052","article-title":"Cement interface and bone stress in total hip arthroplasty: relationship to head size","volume":"36","author":"Alonso-Rasgado","year":"2018","journal-title":"J Orthop Res"},{"key":"10.1016\/j.arth.2026.04.052_bib19","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1186\/s12891-019-2765-z","article-title":"The risk of revision after total hip arthroplasty in young patients depends on surgical approach, femoral head size and bearing type; an analysis of 19,682 operations in the Dutch arthroplasty register","volume":"20","author":"Kuijpers","year":"2019","journal-title":"BMC Musculoskelet Disord"},{"key":"10.1016\/j.arth.2026.04.052_bib20","article-title":"Does a 36-mm head increase cumulative revision rate in total hip arthroplasty when compared to a 32-mm head? A Study from the Australian orthopaedic Association national joint replacement registry","volume":"41","author":"Wallace","year":"2025","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.04.052_bib21","doi-asserted-by":"crossref","first-page":"2367","DOI":"10.1097\/CORR.0000000000000508","article-title":"No increase in survival for 36-mm versus 32-mm femoral heads in metal-on-polyethylene THA: a registry Study","volume":"476","author":"Tsikandylakis","year":"2018","journal-title":"Clin Orthop"},{"key":"10.1016\/j.arth.2026.04.052_bib22","doi-asserted-by":"crossref","first-page":"4163","DOI":"10.1007\/s00402-024-05504-1","article-title":"Head size in Delta ceramic- on-ceramic total hip arthroplasty: a comparative registry study","volume":"144","author":"Castagnini","year":"2024","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.arth.2026.04.052_bib23","doi-asserted-by":"crossref","first-page":"1787","DOI":"10.1016\/j.arth.2023.02.031","article-title":"Femoral head length impact on outcomes following total hip arthroplasty in 36 millimeter cobalt chrome-on-highly crosslinked polyethylene articulations","volume":"38","author":"Salmons","year":"2023","journal-title":"J Arthroplasty"}],"container-title":["The Journal of Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540326003864?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540326003864?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,8,22]],"date-time":"2026-08-22T09:59:18Z","timestamp":1787392758000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0883540326003864"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9]]},"references-count":23,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["S0883540326003864"],"URL":"https:\/\/doi.org\/10.1016\/j.arth.2026.04.052","relation":{},"ISSN":["0883-5403"],"issn-type":[{"value":"0883-5403","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Minimum Two-Year Survivorship of Large Femoral Heads With Titanium Sleeves in Primary Total Hip Arthroplasty: An Analysis From the American Joint Replacement Registry","name":"articletitle","label":"Article Title"},{"value":"The Journal of Arthroplasty","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arth.2026.04.052","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}