{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T12:16:00Z","timestamp":1783426560052,"version":"3.54.6"},"reference-count":25,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["arthroplastyjournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The Journal of Arthroplasty"],"published-print":{"date-parts":[[2026,5]]},"DOI":"10.1016\/j.arth.2026.05.054","type":"journal-article","created":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T05:50:33Z","timestamp":1779429033000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Do Cobalt-Chromium Femoral Heads Have Reduced Revision Risk Compared to Stainless Steel Metal Heads With a Single Cemented Femoral Design? A New Zealand Joint Registry Study"],"prefix":"10.1016","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-3035-8421","authenticated-orcid":false,"given":"Jian-Sen","family":"Ng","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Scott M.","family":"Bolam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher M.A.","family":"Frampton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rocco P.","family":"Pitto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.arth.2026.05.054_bib1","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1186\/s40824-018-0144-8","article-title":"Recent updates for biomaterials used in total hip arthroplasty","volume":"22","author":"Hu","year":"2018","journal-title":"Biomater Res"},{"key":"10.1016\/j.arth.2026.05.054_bib2","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.arth.2011.03.009","article-title":"Comparison of surface characteristics of retrieved cobalt-chromium femoral heads with and without ion implantation","volume":"27","author":"McGrory","year":"2011","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.05.054_bib3","doi-asserted-by":"crossref","first-page":"3945","DOI":"10.1016\/j.arth.2021.08.024","volume":"36","author":"Babazadeh","year":"2021","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.05.054_bib4","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1097\/00003086-200208000-00018","article-title":"A multicenter retrieval study of the taper interfaces of modular hip prostheses","volume":"401","author":"Goldberg","year":"2002","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"10.1016\/j.arth.2026.05.054_bib5","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1002\/jbm.b.31164","article-title":"Fretting crevice corrosion of SS stem\u2013CoCr femoral head connections: comparisons of materials, initial moisture, and offset length","volume":"88B","author":"Gilbert","year":"2008","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"10.1016\/j.arth.2026.05.054_bib6","first-page":"91","article-title":"The tradeoffs associated with modular hip prostheses","volume":"311","author":"Jp","year":"1995","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2026.05.054_bib7","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1097\/00003086-199110000-00042","article-title":"Corrosion at the interface of cobalt-alloy heads on titanium-alloy stems","volume":"271","author":"Collier","year":"1991","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2026.05.054_bib8","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1302\/0301-620X.76B1.8300685","article-title":"Corrosion and wear at the modular interface of uncemented femoral stems","volume":"76-B","author":"Cook","year":"1994","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.arth.2026.05.054_bib9","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1097\/00003086-199403000-00021","article-title":"An analysis of the head-neck taper interface in retrieved hip prostheses","volume":"300","author":"Lieberman","year":"1994","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2026.05.054_bib10","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1016\/j.arth.2012.10.017","article-title":"The influence of head size on corrosion and fretting behaviour at the head-neck interface of artificial hip joints","volume":"28","author":"Dyrkacz","year":"2013","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.05.054_bib11","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1016\/j.arth.2015.01.021","article-title":"Trunnion\u2013head stresses in THA: are big heads trouble?","volume":"30","author":"Lavernia","year":"2015","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.05.054_bib12","doi-asserted-by":"crossref","first-page":"2332","DOI":"10.1016\/j.arth.2016.03.009","article-title":"Trunnionosis: does head size affect fretting and corrosion in total hip arthroplasty?","volume":"31","author":"Del Balso","year":"2016","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.05.054_bib13","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1302\/0301-620X.78B2.0780185","article-title":"Questionnaire on the perceptions of patients about total HIP replacement","volume":"78-B","author":"Dawson","year":"1996","journal-title":"J Bone Joint Surg"},{"key":"10.1016\/j.arth.2026.05.054_bib14","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s10195-016-0391-1","article-title":"Trunnionosis in total hip arthroplasty: a review","volume":"17","author":"Mistry","year":"2016","journal-title":"J Orthop Traumatol"},{"key":"10.1016\/j.arth.2026.05.054_bib15","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1016\/j.arth.2014.11.023","article-title":"Gross trunnion failure after primary total hip arthroplasty","volume":"30","author":"Banerjee","year":"2014","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.05.054_bib16","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.jor.2021.01.008","article-title":"Review: trunnionosis leading to modular femoral head dissociation","volume":"23","author":"Dutta","year":"2021","journal-title":"J Orthop"},{"key":"10.1016\/j.arth.2026.05.054_bib17","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1002\/jor.23601","article-title":"Effect of impact assembly on the interface deformation and fretting corrosion of modular hip tapers: an in vitro study","volume":"36","author":"Panagiotidou","year":"2017","journal-title":"J Orthop Res"},{"key":"10.1016\/j.arth.2026.05.054_bib18","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.arth.2013.05.040","article-title":"Is increased modularity associated with increased fretting and corrosion damage in metal-on-metal total hip arthroplasty devices?","volume":"28","author":"Higgs","year":"2013","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.05.054_bib19","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1007\/s11999-015-4468-6","article-title":"Otto Aufranc Award: large heads do not increase damage at the head-neck taper of metal-on-polyethylene total hip arthroplasties","volume":"474","author":"Triantafyllopoulos","year":"2015","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2026.05.054_bib20","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.1016\/j.arth.2011.11.007","article-title":"Femoral stem fracture and in vivo corrosion of retrieved modular femoral hips","volume":"27","author":"Carlson","year":"2011","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.05.054_bib22","doi-asserted-by":"crossref","first-page":"2857","DOI":"10.1016\/j.arth.2017.03.075","article-title":"Trunnion failure of the recalled low friction ion treatment cobalt chromium alloy femoral head","volume":"32","author":"Urish","year":"2017","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.05.054_bib23","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1177\/1120700020919665","article-title":"Catastrophic failure of the accolade I hip arthroplasty stem: a retrieval analysis study","volume":"30","author":"Wylde","year":"2020","journal-title":"Hip Int"},{"key":"10.1016\/j.arth.2026.05.054_bib24","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1016\/S0883-5403(06)80095-1","article-title":"Polyethylene wear in total hip arthroplasty in patient-matched groups","volume":"8","author":"Bankston","year":"1993","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.arth.2026.05.054_bib25","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1097\/00003086-200001000-00017","article-title":"Effect of low friction ion treated femoral heads on polyethylene wear rates","volume":"370","author":"Maruyama","year":"2000","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.arth.2026.05.054_bib26","doi-asserted-by":"crossref","first-page":"2543","DOI":"10.1111\/ans.16385","article-title":"Completeness and capture rate of publicly funded arthroplasty procedures in the New Zealand Joint Registry","volume":"90","author":"Rahardja","year":"2020","journal-title":"ANZ J Surg"}],"container-title":["The Journal of Arthroplasty"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540326005711?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0883540326005711?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T11:30:17Z","timestamp":1783423817000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0883540326005711"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5]]},"references-count":25,"alternative-id":["S0883540326005711"],"URL":"https:\/\/doi.org\/10.1016\/j.arth.2026.05.054","relation":{},"ISSN":["0883-5403"],"issn-type":[{"value":"0883-5403","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Do Cobalt-Chromium Femoral Heads Have Reduced Revision Risk Compared to Stainless Steel Metal Heads With a Single Cemented Femoral Design? A New Zealand Joint Registry Study","name":"articletitle","label":"Article Title"},{"value":"The Journal of Arthroplasty","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arth.2026.05.054","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}