{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T21:37:09Z","timestamp":1773610629879,"version":"3.50.1"},"reference-count":24,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2004,7,1]],"date-time":"2004-07-01T00:00:00Z","timestamp":1088640000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2004,7,1]],"date-time":"2004-07-01T00:00:00Z","timestamp":1088640000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Arthroscopy"],"published-print":{"date-parts":[[2004,7]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The purpose of this study was to examine the neurovascular structures at risk during placement of glenohumeral arthroscopy portals using an outside\u2013in technique.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Type of study<\/jats:title>\n                    <jats:p>Anatomic cadaveric study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Five fresh\u2010frozen cadaveric specimens were used in this study. Each shoulder was mounted on a custom\u2010designed apparatus allowing shoulder arthroscopy in a lateral decubitus position. The following portals were established using an outside\u2013in technique and marked using an 18\u2010gauge spinal needle: posterior, posterolateral, anterior, 5\u2010o'clock, anterosuperolateral, and Port of Wilmington. Each specimen was carefully dissected after the procedure, and the distance from each portal site to the adjacent relevant neurovascular structures (axillary nerve, musculocutaneous nerve, lateral cord of the brachial plexus, cephalic vein, and axillary artery) was measured using a precision caliper.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Except for the cephalic vein, all of the neurovascular structures were more than 20 mm away from all the portals evaluated. When creating either an anterior portal or a 5\u2010o'clock position portal, the mean distance from the portal to the cephalic vein was 18.8 mm and 9.8 mm, respectively. In one anterior portal, a direct injury to the cephalic vein occurred.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Our study suggests that shoulder arthroscopy portals placed in an outside\u2013in fashion are unlikely to produce neurologic injury. However, the cephalic vein is at risk during placement of an anterior or 5\u2010o'clock position portal, although probably with minimal subsequent patient morbidity. Placing portals in an outside\u2013in fashion guarantees the correct angle of approach, with minimal risk to adjacent neurologic structures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical relevance<\/jats:title>\n                    <jats:p>This study shows the safety of standard and accessory glenohumeral arthroscopy portals.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.arthro.2004.04.057","type":"journal-article","created":{"date-parts":[[2004,7,6]],"date-time":"2004-07-06T14:21:04Z","timestamp":1089123664000},"page":"596-602","source":"Crossref","is-referenced-by-count":80,"title":["Glenohumeral arthroscopy portals established using an outside\u2013In technique: neurovascular anatomy at risk"],"prefix":"10.1002","volume":"20","author":[{"given":"Ian K.Y.","family":"Lo","sequence":"first","affiliation":[{"name":"The San Antonio Orthopaedic Group San Antonio Texas U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charles C.","family":"Lind","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Texas Health Science Center at San Antonio San Antonio Texas U.S.A"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephen S.","family":"Burkhart","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Texas Health Science Center at San Antonio San Antonio Texas U.S.A"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2004,7,1]]},"reference":[{"key":"e_1_2_2_2_1","doi-asserted-by":"publisher","DOI":"10.1053\/jars.2002.31801"},{"key":"e_1_2_2_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1058-2746(96)80073-5"},{"key":"e_1_2_2_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/0749-8063(92)90080-U"},{"key":"e_1_2_2_5_1","first-page":"743","article-title":"Complications of shoulder arthroscopy","volume":"20","author":"Bigliani L.U.","year":"1991","journal-title":"Orthop Rev"},{"key":"e_1_2_2_6_1","first-page":"190","article-title":"Complications of shoulder arthroscopy","volume":"6","author":"McFarland E.G.","year":"1997","journal-title":"J South Orthop Assoc"},{"key":"e_1_2_2_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0278-5919(05)70183-6"},{"key":"e_1_2_2_8_1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199306000-00015"},{"key":"e_1_2_2_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(88)80039-2"},{"key":"e_1_2_2_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1058-2746(05)80017-5"},{"key":"e_1_2_2_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(85)80076-1"},{"key":"e_1_2_2_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/0749-8063(95)90201-5"},{"key":"e_1_2_2_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0030-5898(21)00031-6"},{"key":"e_1_2_2_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(97)90187-0"},{"key":"e_1_2_2_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(96)90206-6"},{"key":"e_1_2_2_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(96)90063-8"},{"key":"e_1_2_2_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/0749-8063(89)90172-2"},{"key":"e_1_2_2_18_1","doi-asserted-by":"publisher","DOI":"10.1177\/03635465990270050401"},{"key":"e_1_2_2_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/0749-8063(95)90126-4"},{"key":"e_1_2_2_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0030-5898(05)70212-1"},{"key":"e_1_2_2_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0278-5919(05)70300-8"},{"key":"e_1_2_2_22_1","doi-asserted-by":"publisher","DOI":"10.1097\/00132589-200106000-00002"},{"key":"e_1_2_2_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(98)70049-0"},{"key":"e_1_2_2_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1048-6666(01)80030-6"},{"key":"e_1_2_2_25_1","first-page":"372","article-title":"The trans\u2010rotator cuff approach to SLAP lesions. Technical aspects for repair and a clinical follow\u2010up of 31 patients at a minimum 2 year follow\u2010up","volume":"18","author":"O'Brien S.J.","year":"2002","journal-title":"Arthroscopy"}],"container-title":["Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806304005377?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806304005377?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2004.04.057","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.arthro.2004.04.057","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2004.04.057","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T09:18:38Z","timestamp":1773566318000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.arthro.2004.04.057"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,7]]},"references-count":24,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2004,7]]}},"alternative-id":["10.1016\/j.arthro.2004.04.057"],"URL":"https:\/\/doi.org\/10.1016\/j.arthro.2004.04.057","archive":["Portico"],"relation":{},"ISSN":["0749-8063","1526-3231"],"issn-type":[{"value":"0749-8063","type":"print"},{"value":"1526-3231","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,7]]}}}