{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T20:38:38Z","timestamp":1773607118947,"version":"3.50.1"},"reference-count":14,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2007,10,4]],"date-time":"2007-10-04T00:00:00Z","timestamp":1191456000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2007,10,4]],"date-time":"2007-10-04T00:00:00Z","timestamp":1191456000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Arthroscopy"],"published-print":{"date-parts":[[2008,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Methods for the repair of meniscal tears include inside\u2010out, outside\u2010in, and all\u2010inside techniques. In this article an all\u2010inside technique is proposed for the posterior horn of the lateral meniscus that takes advantage of the capacious posterolateral recess when the knee is flexed. A device consisting of a large needle with a buttonhole in the tip (previously used for inside\u2010out suture of the medial meniscus) is used. This technique uses only anterior portals (anteromedial and anterolateral portals and an accessory lateral or transpatellar tendon portal). The arthroscope is inserted through the accessory portal. Once the tear has been located and its edges refreshed, the suture device is placed anterolaterally. The tip of the needle is loaded with suture and passed through both sides of the tear and into the posterolateral recess of the knee (without exiting the capsule). The suture tail is recovered with the use of a suture retriever through the anteromedial portal. Next, the suture retriever is inserted through the anterolateral portal to once again retrieve and shuttle the tail before completion of an arthroscopic knot. In addition to the ease of the technique, use of this simple, reusable device adds the benefit of low cost when compared with other techniques.<\/jats:p>","DOI":"10.1016\/j.arthro.2007.06.017","type":"journal-article","created":{"date-parts":[[2007,10,4]],"date-time":"2007-10-04T10:45:34Z","timestamp":1191494734000},"source":"Crossref","is-referenced-by-count":17,"title":["All\u2010Inside Suture Technique Using Anterior Portals in Posterior Horn Tears of Lateral Meniscus"],"prefix":"10.1002","volume":"24","author":[{"given":"Alejandro","family":"Espejo\u2010Baena","sequence":"first","affiliation":[{"name":"Servicio de Cirugia Ortopedica y Traumatologia Hospital Clinico Universitario Virgen de la Victoria M\u00e1laga Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alejandro","family":"Figueroa\u2010Mata","sequence":"additional","affiliation":[{"name":"Servicio de Cirugia Ortopedica y Traumatologia Hospital Clinico Universitario Virgen de la Victoria M\u00e1laga Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jos\u00e9","family":"Serrano\u2010Fern\u00e1ndez","sequence":"additional","affiliation":[{"name":"Servicio de Cirugia Ortopedica y Traumatologia Hospital Clinico Universitario Virgen de la Victoria M\u00e1laga Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francisco","family":"de la Torre\u2010Sol\u00eds","sequence":"additional","affiliation":[{"name":"Servicio de Cirugia Ortopedica y Traumatologia Hospital Clinico Universitario Virgen de la Victoria M\u00e1laga Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2007,10,4]]},"reference":[{"key":"e_1_2_2_2_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-006-0096-8"},{"key":"e_1_2_2_3_1","first-page":"35","article-title":"Sutura de menisco interno: An\u00e1lisis del riesgo de lesi\u00f3n popl\u00edtea neurovascular mediante resonancia magn\u00e9tica din\u00e1mica","volume":"13","author":"Fern\u00e1ndez de Rota A.","year":"2006","journal-title":"Cuad Artrosc"},{"issue":"2","key":"e_1_2_2_4_1","first-page":"91","article-title":"Sutura meniscal: An\u00e1lisis del riesgo de lesi\u00f3n del nervio ci\u00e1tico popl\u00edteo externo","volume":"50","author":"Fern\u00e1ndez de Rota A.","year":"2006","journal-title":"Rev Ortop Trauma"},{"key":"e_1_2_2_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/00132585-200609000-00003"},{"key":"e_1_2_2_6_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546506293023"},{"key":"e_1_2_2_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/0749-8063(91)90093-D"},{"key":"e_1_2_2_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2005.07.031"},{"key":"e_1_2_2_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2003.11.008"},{"key":"e_1_2_2_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(04)00547-X"},{"key":"e_1_2_2_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2004.07.006"},{"key":"e_1_2_2_12_1","first-page":"100","article-title":"Outcomes of meniscal repair: Minimum of 2\u2010year follow\u2010up","volume":"63","author":"Tuckman D.V.","year":"2006","journal-title":"Bull Hosp Jt Dis"},{"key":"e_1_2_2_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0035-1040(05)84550-7"},{"key":"e_1_2_2_14_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546505278254"},{"key":"e_1_2_2_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-006-0094-x"}],"container-title":["Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806307006664?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806307006664?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2007.06.017","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.arthro.2007.06.017","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2007.06.017","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T08:41:54Z","timestamp":1773564114000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.arthro.2007.06.017"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,10,4]]},"references-count":14,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2008,3]]}},"alternative-id":["10.1016\/j.arthro.2007.06.017"],"URL":"https:\/\/doi.org\/10.1016\/j.arthro.2007.06.017","archive":["Portico"],"relation":{},"ISSN":["0749-8063","1526-3231"],"issn-type":[{"value":"0749-8063","type":"print"},{"value":"1526-3231","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,10,4]]}}}