{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T21:19:40Z","timestamp":1773609580478,"version":"3.50.1"},"reference-count":28,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2009,9,1]],"date-time":"2009-09-01T00:00:00Z","timestamp":1251763200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2009,9,1]],"date-time":"2009-09-01T00:00:00Z","timestamp":1251763200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2009,9,1]],"date-time":"2009-09-01T00:00:00Z","timestamp":1251763200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2009,9,1]],"date-time":"2009-09-01T00:00:00Z","timestamp":1251763200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["arthroscopyjournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy"],"published-print":{"date-parts":[[2009,9]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To assess how suture type and suture construct in an augmented Weaver\u2010Dunn reconstruction affect coracoclavicular sling failure and rotary stability.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Fifteen cadaveric shoulders were tested in rotation about the long axis of the clavicle with 10 lb of simulated arm weight. The clavicle was rotated 50\u00b0 about its long axis, and the applied torque was recorded. Next, modified Weaver\u2010Dunn reconstruction was conducted. Two types of coracoclavicular sling (opposed drill holes through the clavicle and complete loop around the clavicle) were tested by use of 3 different sutures (FiberWire [Arthrex, Naples, FL], Mersilene tape [Ethicon, Somerville, NJ], and braided polydioxanone [PDS] [Ethicon]). For each sling\u2010suture combination, the joint was retested over 50\u00b0 of rotation and then cycled over 40\u00b0 of rotation for 15,000 cycles or until failure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      After modified Weaver\u2010Dunn reconstruction with either sling construct, mean torque over 50\u00b0 of acromioclavicular rotation was significantly reduced in posterior (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .0001) and anterior (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .0001) rotation, with any suture material tested. When the coracoclavicular sling was placed through opposed drill holes, no wear to the bone or suture was observed. When the sling material was looped around the clavicle, FiberWire and PDS resulted in abrasion of soft tissue and periosteum. In all cases sawing motion between bone and suture was observed at the coracoid. The FiberWire itself failed at a mean of 8,213 cycles. Some wear was noted in the Mersilene tape. PDS suture showed no wear.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In a cadaveric model of modified Weaver\u2010Dunn reconstruction, a coracoclavicular suture loop was used to augment coracoacromial ligament transfer. Suture loops secured around the entire clavicle were shown to contribute to increased abrasive wear. Securing suture loops through opposed drill holes in the clavicle resulted in decreased abrasive wear.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance<\/jats:title>\n                    <jats:p>Proper selection of suture type and suture construct may affect the failure rate of augmented Weaver\u2010Dunn reconstructions.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.arthro.2009.03.016","type":"journal-article","created":{"date-parts":[[2009,9,3]],"date-time":"2009-09-03T07:58:20Z","timestamp":1251964700000},"page":"975-982","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":24,"title":["Failure of Coracoclavicular Artificial Graft Reconstructions From Repetitive Rotation"],"prefix":"10.1002","volume":"25","author":[{"given":"Matthew A.","family":"Kippe","sequence":"first","affiliation":[{"name":"William Beaumont Hospital Research Institute Royal Oak Michigan U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Constantine K.","family":"Demetropoulos","sequence":"additional","affiliation":[{"name":"William Beaumont Hospital Research Institute Royal Oak Michigan U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kevin C.","family":"Baker","sequence":"additional","affiliation":[{"name":"William Beaumont Hospital Research Institute Royal Oak Michigan U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenneth A.","family":"Jurist","sequence":"additional","affiliation":[{"name":"William Beaumont Hospital Research Institute Royal Oak Michigan U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph H.","family":"Guettler","sequence":"additional","affiliation":[{"name":"William Beaumont Hospital Research Institute Royal Oak Michigan U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2009,9,1]]},"reference":[{"key":"e_1_2_3_2_1","doi-asserted-by":"publisher","DOI":"10.1177\/03635465010290022001"},{"key":"e_1_2_3_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2005.07.020"},{"key":"e_1_2_3_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0278-5919(03)00014-0"},{"key":"e_1_2_3_5_1","doi-asserted-by":"publisher","DOI":"10.1177\/03635465030310050401"},{"key":"e_1_2_3_6_1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197254060-00005"},{"key":"e_1_2_3_7_1","doi-asserted-by":"publisher","DOI":"10.1177\/036354659502300506"},{"key":"e_1_2_3_8_1","doi-asserted-by":"publisher","DOI":"10.1177\/036354659502300118"},{"key":"e_1_2_3_9_1","doi-asserted-by":"publisher","DOI":"10.1177\/03635465000280010201"},{"key":"e_1_2_3_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2004.01.011"},{"key":"e_1_2_3_11_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546506298022"},{"key":"e_1_2_3_12_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546505281795"},{"key":"e_1_2_3_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2006.09.006"},{"key":"e_1_2_3_14_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546507304715"},{"key":"e_1_2_3_15_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546504263699"},{"key":"e_1_2_3_16_1","first-page":"120","article-title":"Velour prosthesis in fractures and luxations in the clavicular region: A follow\u2010up study","volume":"53","author":"Dahl E.","year":"1982","journal-title":"Chirurg"},{"key":"e_1_2_3_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1445-2197.1987.tb01394.x"},{"key":"e_1_2_3_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-198208000-00026"},{"key":"e_1_2_3_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2008.06.008"},{"key":"e_1_2_3_20_1","first-page":"3","article-title":"Observations of the function of the shoulder joint","author":"Inman V.T.","year":"1944","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_2_3_21_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546508319048"},{"key":"e_1_2_3_22_1","volume-title":"The shoulder","author":"Codman E.A.","year":"1934"},{"key":"e_1_2_3_23_1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-196244050-00013"},{"key":"e_1_2_3_24_1","doi-asserted-by":"publisher","DOI":"10.2519\/jospt.2004.34.3.140"},{"key":"e_1_2_3_25_1","doi-asserted-by":"publisher","DOI":"10.1002\/jor.20407"},{"key":"e_1_2_3_26_1","doi-asserted-by":"publisher","DOI":"10.2519\/jospt.2008.2386"},{"key":"e_1_2_3_27_1","doi-asserted-by":"publisher","DOI":"10.1177\/036354659602400308"},{"key":"e_1_2_3_28_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546504264637"},{"key":"e_1_2_3_29_1","volume-title":"Suture repair technique for acute and chronic acromioclavicular dislocations [educational videotape]","author":"Noble J.","year":"1993"}],"container-title":["Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806309002412?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806309002412?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2009.03.016","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.arthro.2009.03.016","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2009.03.016","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T09:07:21Z","timestamp":1773565641000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.arthro.2009.03.016"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,9]]},"references-count":28,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2009,9]]}},"alternative-id":["10.1016\/j.arthro.2009.03.016"],"URL":"https:\/\/doi.org\/10.1016\/j.arthro.2009.03.016","archive":["Portico"],"relation":{},"ISSN":["0749-8063","1526-3231"],"issn-type":[{"value":"0749-8063","type":"print"},{"value":"1526-3231","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Failure of Coracoclavicular Artificial Graft Reconstructions From Repetitive Rotation","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy: The Journal of Arthroscopic & Related Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arthro.2009.03.016","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2009 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}