{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T16:20:33Z","timestamp":1793982033874,"version":"4.8.0"},"reference-count":16,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2010,10,1]],"date-time":"2010-10-01T00:00:00Z","timestamp":1285891200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2010,10,1]],"date-time":"2010-10-01T00:00:00Z","timestamp":1285891200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2010,10,1]],"date-time":"2010-10-01T00:00:00Z","timestamp":1285891200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2010,10,1]],"date-time":"2010-10-01T00:00:00Z","timestamp":1285891200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["arthroscopyjournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy"],"published-print":{"date-parts":[[2010,10]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The purpose was to measure anterior cruciate ligament (ACL) femoral tunnel lengths comparing anteromedial (AM) portal and outside\u2010in techniques.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>ACL femoral guide pins were drilled into 12 cadaveric knees through the AM portal technique and then the outside\u2010in technique in each specimen. Pin intraosseous distance was measured in millimeters by a MicroScribe 3\u2010dimensional digitizer (Immersion, San Jose, CA).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      With the AM portal technique, the mean ACL femoral tunnel distance was 30.5 mm. With the outside\u2010in technique, the mean ACL femoral tunnel distance was 34.1 mm. The difference was statistically significant (\n                      <jats:italic>P<\/jats:italic>\n                      = .04).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Our results show that the outside\u2010in technique for creating the ACL femoral tunnel results in a longer mean tunnel length than the AM portal technique for creating the ACL femoral tunnel. The outside\u2010in technique best prevents excessively short tunnels.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance<\/jats:title>\n                    <jats:p>Our results have clinical relevance for surgeons who desire to perform independent, rather than transtibial, drilling of the ACL femoral tunnel and desire adequate length of tendon graft within the femoral bone tunnel.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.arthro.2010.02.014","type":"journal-article","created":{"date-parts":[[2010,9,30]],"date-time":"2010-09-30T05:26:45Z","timestamp":1285824405000},"page":"1357-1362","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":103,"title":["Anterior Cruciate Ligament Femoral Tunnel Length: Cadaveric Analysis Comparing Anteromedial Portal Versus Outside\u2010In Technique"],"prefix":"10.1002","volume":"26","author":[{"given":"James H.","family":"Lubowitz","sequence":"first","affiliation":[{"name":"Taos Orthopaedic Institute Research Foundation Taos New Mexico U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Konicek","sequence":"additional","affiliation":[{"name":"Department of Research and Bioengineering Arthrex, Inc. Naples Florida U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2010,10,1]]},"reference":[{"key":"e_1_2_2_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(05)80004-0"},{"key":"e_1_2_2_3_1","doi-asserted-by":"publisher","DOI":"10.1053\/ar.1999.v15.015059"},{"key":"e_1_2_2_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2007.06.013"},{"key":"e_1_2_2_5_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0030-1247745"},{"key":"e_1_2_2_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2007.09.013"},{"key":"e_1_2_2_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2007.10.012"},{"key":"e_1_2_2_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2008.04.054"},{"key":"e_1_2_2_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2007.07.019"},{"key":"e_1_2_2_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2008.10.012"},{"key":"e_1_2_2_11_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.otsm.2006.04.005"},{"key":"e_1_2_2_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.bto.0000177603.05129.13"},{"key":"e_1_2_2_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2005.05.032"},{"key":"e_1_2_2_14_1","unstructured":"ACL reconstruction with the FlipCutter: OrthoIllustrated.http:\/\/www.orthoillustrated.com\/index.cfm?ResDiaRelID=107 Accessed on July 11 2009"},{"key":"e_1_2_2_15_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546508320572"},{"key":"e_1_2_2_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2008.11.010"},{"key":"e_1_2_2_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(99)70007-1"}],"container-title":["Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806310001830?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806310001830?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2010.02.014","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.arthro.2010.02.014","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2010.02.014","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T08:51:37Z","timestamp":1773564697000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.arthro.2010.02.014"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,10]]},"references-count":16,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2010,10]]}},"alternative-id":["10.1016\/j.arthro.2010.02.014"],"URL":"https:\/\/doi.org\/10.1016\/j.arthro.2010.02.014","archive":["Portico"],"relation":{},"ISSN":["0749-8063","1526-3231"],"issn-type":[{"value":"0749-8063","type":"print"},{"value":"1526-3231","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Anterior Cruciate Ligament Femoral Tunnel Length: Cadaveric Analysis Comparing Anteromedial Portal Versus Outside-In Technique","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy: The Journal of Arthroscopic & Related Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arthro.2010.02.014","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}