{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T18:45:25Z","timestamp":1773600325073,"version":"3.50.1"},"reference-count":27,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2017,1,14]],"date-time":"2017-01-14T00:00:00Z","timestamp":1484352000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2017,1,14]],"date-time":"2017-01-14T00:00:00Z","timestamp":1484352000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2017,1,14]],"date-time":"2017-01-14T00:00:00Z","timestamp":1484352000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","arthroscopyjournal.org","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy"],"published-print":{"date-parts":[[2017,5]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The purpose of this study was to evaluate the time zero cyclic and failure loading properties of a linked single\u2010row rotator cuff repair compared with a standard simple suture single\u2010row repair using triple\u2010loaded suture anchors.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Eighteen human cadaveric shoulders from 9 matched pairs were dissected, and full\u2010thickness supraspinatus tears were created. The tendon cross\u2010sectional area was recorded. In each pair, one side was repaired with a linked single\u2010row construct and the other with a simple suture single\u2010row construct, both using 2 triple\u2010loaded suture anchors. After preloading, specimens were cycled to 1\u00a0MPa of effective stress at 1\u00a0Hz for 500 cycles, and gap formation was recorded with a digital video system. Samples were then loaded to failure, and modes of failure were recorded.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      There was no statistical difference in peak gap formation between the control and linked constructs (3.6 \u00b1 0.9\u00a0mm and 3.6 \u00b1 1.2\u00a0mm, respectively;\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .697). Both constructs averaged below a 5\u2010mm cyclic failure threshold. There was no statistical difference in ultimate load to failure between the control and linked repair (511.1 \u00b1 139.0\u00a0N and 561.2 \u00b1 131.8\u00a0N, respectively;\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0=\u00a0.164), and both groups reached failure at loads similar to previous studies. Constructs failed predominantly via tissue tearing parallel to the medial suture line.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The linked repair performed similarly to the simple single\u2010row repair. Both constructs demonstrated high ultimate load to failure and good resistance to gap formation with cyclic loading, validating the time zero strength of both constructs in a human cadaveric model.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance<\/jats:title>\n                    <jats:p>The linked repair provided equivalent resistance to gap formation and failure loads compared with simple suture single\u2010row repairs with triple\u2010loaded suture anchors. This suggests that the linked repair is a simplified rip\u2010stop configuration using the existing suture that may perform similarly to current rotator cuff repair techniques.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.arthro.2016.10.014","type":"journal-article","created":{"date-parts":[[2017,1,12]],"date-time":"2017-01-12T11:09:53Z","timestamp":1484219393000},"page":"938-944","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"title":["Biomechanical Comparison of Standard and Linked Single\u2010Row Rotator Cuff Repairs in a Human Cadaver Model"],"prefix":"10.1002","volume":"33","author":[{"given":"Adam F.","family":"Meisel","sequence":"first","affiliation":[{"name":"Southern California Orthopedic Institute Van Nuys California U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Heath B.","family":"Henninger","sequence":"additional","affiliation":[{"name":"Departments of Orthopaedics and Bioengineering University of Utah Salt Lake City Utah U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F. Alan","family":"Barber","sequence":"additional","affiliation":[{"name":"Plano Orthopedics Sports Medicine and Spine Center Plano Texas U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark H.","family":"Getelman","sequence":"additional","affiliation":[{"name":"Southern California Orthopedic Institute Van Nuys California U.S.A."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2017,1,14]]},"reference":[{"key":"e_1_2_2_2_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200402000-00002"},{"key":"e_1_2_2_3_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199173070-00004"},{"key":"e_1_2_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(96)90174-7"},{"key":"e_1_2_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2011.08.298"},{"key":"e_1_2_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2012.02.015"},{"key":"e_1_2_2_7_2","doi-asserted-by":"publisher","DOI":"10.1067\/mse.2003.21"},{"key":"e_1_2_2_8_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546513516602"},{"key":"e_1_2_2_9_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.76B3.8175836"},{"key":"e_1_2_2_10_2","doi-asserted-by":"publisher","DOI":"10.1053\/jars.2003.50079"},{"key":"e_1_2_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2006.04.011"},{"key":"e_1_2_2_12_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546506289701"},{"key":"e_1_2_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/0197-2456(88)90047-5"},{"key":"e_1_2_2_14_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200311000-00021"},{"key":"e_1_2_2_15_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00223-002-0013-9"},{"key":"e_1_2_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2006.12.009"},{"key":"e_1_2_2_17_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546514553091"},{"key":"e_1_2_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(97)90151-1"},{"key":"e_1_2_2_19_2","doi-asserted-by":"publisher","DOI":"10.3758\/BF03193146"},{"key":"e_1_2_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2006.05.020"},{"key":"e_1_2_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2009.07.019"},{"key":"e_1_2_2_22_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100130413"},{"key":"e_1_2_2_23_2","doi-asserted-by":"publisher","DOI":"10.1002\/ca.22322"},{"key":"e_1_2_2_24_2","doi-asserted-by":"publisher","DOI":"10.1067\/mse.2000.106321"},{"key":"e_1_2_2_25_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.4028820"},{"key":"e_1_2_2_26_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.F.00880"},{"key":"e_1_2_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2011.01.040"},{"key":"e_1_2_2_28_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546509337450"}],"container-title":["Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806316308866?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806316308866?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2016.10.014","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.arthro.2016.10.014","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2016.10.014","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T08:48:17Z","timestamp":1773564497000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.arthro.2016.10.014"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1,14]]},"references-count":27,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2017,5]]}},"alternative-id":["10.1016\/j.arthro.2016.10.014"],"URL":"https:\/\/doi.org\/10.1016\/j.arthro.2016.10.014","archive":["Portico"],"relation":{},"ISSN":["0749-8063","1526-3231"],"issn-type":[{"value":"0749-8063","type":"print"},{"value":"1526-3231","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,1,14]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Biomechanical Comparison of Standard and Linked Single-Row Rotator Cuff Repairs in a Human Cadaver Model","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy: The Journal of Arthroscopic & Related Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arthro.2016.10.014","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 by the Arthroscopy Association of North America","name":"copyright","label":"Copyright"}]}}