{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T07:46:13Z","timestamp":1794642373480,"version":"4.9.1"},"reference-count":46,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2017,12,21]],"date-time":"2017-12-21T00:00:00Z","timestamp":1513814400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2017,12,21]],"date-time":"2017-12-21T00:00:00Z","timestamp":1513814400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2017,12,21]],"date-time":"2017-12-21T00:00:00Z","timestamp":1513814400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","arthroscopyjournal.org","clinicalkey.fr","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy"],"published-print":{"date-parts":[[2018,2]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To compare the dynamic elongation, stiffness behavior, and ultimate failure load of standard with small diameter soft tissue grafts for anterior cruciate ligament (ACL) reconstruction with and without high\u2010strength suture tape reinforcement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Both a tripled \u201csmall\u201d diameter and a \u201cstandard\u201d quadrupled tendon graft with and without suture tape reinforcement were tested using suspensory fixation (n\u00a0= 8 each group). The suture tape was passed through the suspensory fixation button on the femur and tibia to ensure independent (safety belt) fixation from the graft in\u00a0vitro. The testing of the constructs included position\u2010controlled cyclic loading, force\u2010controlled cyclic loading at 250\u00a0N and 400\u00a0N as well as pull to failure (50\u00a0mm\/min).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Reinforcement of a small diameter graft significantly reduced dynamic elongation of 38% (1.46 \u00b1 0.28\u00a0mm vs 2.34 \u00b1 0.44\u00a0mm,\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .001) and 50% (2.55 \u00b1 0.44\u00a0mm vs 5.06 \u00b1 0.67\u00a0mm,\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .001) after the 250\u00a0N and 400\u00a0N load protocol, respectively. Reinforcement of a standard diameter tendon graft decreased dynamic elongation of 15% (1.59 \u00b1 0.34\u00a0mm vs 1.86 \u00b1 0.17\u00a0mm,\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .066) and 26% (2.62 \u00b1 0.44\u00a0mm vs 3.55 \u00b1 0.44\u00a0mm,\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .001). No significant difference was found between both reinforced models. The ultimate failure loads of small and standard diameter reinforced grafts were 1592 \u00b1 105\u00a0N and 1585 \u00b1 265\u00a0N, resulting in a 64% (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .001) and 40% (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .001) increase compared with their respective controls.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Independent suture tape reinforcement of soft tissue grafts for ACL reconstruction leads to significantly reduced elongation and higher ultimate failure load according to in\u00a0vivo native ACL function data without stress\u2010shielding the soft tissue graft.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance<\/jats:title>\n                    <jats:p>If in\u00a0vitro results are translational to human knees in\u00a0vivo, the suture tape reinforcement technique for ACL reconstruction may decrease the risk of graft tears, particularly in the case of small diameter soft tissue grafts.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.arthro.2017.10.037","type":"journal-article","created":{"date-parts":[[2017,12,21]],"date-time":"2017-12-21T09:06:31Z","timestamp":1513847191000},"page":"490-499","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":119,"title":["Independent Suture Tape Reinforcement of Small and Standard Diameter Grafts for Anterior Cruciate Ligament Reconstruction: A Biomechanical Full Construct Model"],"prefix":"10.1002","volume":"34","author":[{"given":"Samuel","family":"Bachmaier","sequence":"first","affiliation":[{"name":"Arthrex Department of Research &amp; Development Munich Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick A.","family":"Smith","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Missouri Columbia Missouri U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jordan","family":"Bley","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Missouri Columbia Missouri U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Coen A.","family":"Wijdicks","sequence":"additional","affiliation":[{"name":"Arthrex Department of Research &amp; Development Munich Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2017,12,21]]},"reference":[{"key":"e_1_2_2_2_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546514542796"},{"key":"e_1_2_2_3_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMcp0804745"},{"key":"e_1_2_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2016.06.009"},{"key":"e_1_2_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2012.06.016"},{"key":"e_1_2_2_6_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546514541935"},{"key":"e_1_2_2_7_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546510370929"},{"key":"e_1_2_2_8_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.K.00733"},{"key":"e_1_2_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2014.10.013"},{"key":"e_1_2_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2014.03.028"},{"key":"e_1_2_2_11_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546508319901"},{"key":"e_1_2_2_12_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546516634011"},{"key":"e_1_2_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2011.11.024"},{"key":"e_1_2_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2013.08.025"},{"key":"e_1_2_2_15_2","doi-asserted-by":"publisher","DOI":"10.1177\/036354658000800101"},{"key":"e_1_2_2_16_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546516677545"},{"key":"e_1_2_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2015.06.003"},{"key":"e_1_2_2_18_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-016-4150-x"},{"key":"e_1_2_2_19_2","article-title":"Is there a role for internal bracing and repair of the anterior cruciate ligament?","volume":"1","author":"Eck C.F.","year":"2017","journal-title":"Am J Sports Med"},{"key":"e_1_2_2_20_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546514548164"},{"key":"e_1_2_2_21_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.95B5.30872"},{"key":"e_1_2_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2014.12.023"},{"key":"e_1_2_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2015.01.013"},{"key":"e_1_2_2_24_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10195-016-0420-0"},{"key":"e_1_2_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2010.09.003"},{"key":"e_1_2_2_26_2","doi-asserted-by":"publisher","DOI":"10.1210\/endo.139.2.5751"},{"key":"e_1_2_2_27_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.1351889"},{"key":"e_1_2_2_28_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.otsm.2012.11.001"},{"key":"e_1_2_2_29_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-014-3410-x"},{"key":"e_1_2_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.orthres.2004.08.006"},{"key":"e_1_2_2_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2003.10.010"},{"key":"e_1_2_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0268-0033(99)00063-7"},{"key":"e_1_2_2_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2012.10.031"},{"key":"e_1_2_2_34_2","doi-asserted-by":"publisher","DOI":"10.1177\/036354659101900303"},{"key":"e_1_2_2_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2013.02.020"},{"key":"e_1_2_2_36_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-005-0679-9"},{"key":"e_1_2_2_37_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-198466030-00005"},{"key":"e_1_2_2_38_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF00182976"},{"key":"e_1_2_2_39_2","doi-asserted-by":"publisher","DOI":"10.1177\/036354659502300105"},{"key":"e_1_2_2_40_2","doi-asserted-by":"publisher","DOI":"10.1177\/036354659702500616"},{"key":"e_1_2_2_41_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-004-0601-x"},{"key":"e_1_2_2_42_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2015.11.011"},{"key":"e_1_2_2_43_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199303000-00009"},{"key":"e_1_2_2_44_2","doi-asserted-by":"publisher","DOI":"10.3233\/THC-2006-144-515"},{"key":"e_1_2_2_45_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100080408"},{"key":"e_1_2_2_46_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546504265924"},{"key":"e_1_2_2_47_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-016-2529-2"}],"container-title":["Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S074980631731383X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S074980631731383X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2017.10.037","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.arthro.2017.10.037","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2017.10.037","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T09:28:59Z","timestamp":1773566939000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.arthro.2017.10.037"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,12,21]]},"references-count":46,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018,2]]}},"alternative-id":["10.1016\/j.arthro.2017.10.037"],"URL":"https:\/\/doi.org\/10.1016\/j.arthro.2017.10.037","archive":["Portico"],"relation":{},"ISSN":["0749-8063","1526-3231"],"issn-type":[{"value":"0749-8063","type":"print"},{"value":"1526-3231","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,12,21]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Independent Suture Tape Reinforcement of Small and Standard Diameter Grafts for Anterior Cruciate Ligament Reconstruction: A Biomechanical Full Construct Model","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy: The Journal of Arthroscopic & Related Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arthro.2017.10.037","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Published by Elsevier on behalf of the Arthroscopy Association of North America","name":"copyright","label":"Copyright"}]}}