{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T18:11:37Z","timestamp":1790705497615,"version":"4.1.0"},"reference-count":25,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2018,11,22]],"date-time":"2018-11-22T00:00:00Z","timestamp":1542844800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2018,11,22]],"date-time":"2018-11-22T00:00:00Z","timestamp":1542844800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2018,11,22]],"date-time":"2018-11-22T00:00:00Z","timestamp":1542844800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,11,22]],"date-time":"2018-11-22T00:00:00Z","timestamp":1542844800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["arthroscopyjournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy"],"published-print":{"date-parts":[[2019,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To analyze the failure mechanism, stiffness, and pullout strength of acetabular knotless suture anchors.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Seven suture anchors were tested in high\u2010density (0.48\u00a0g\/cc) synthetic blocks. The anchors were implanted perpendicular to the bone block. The anchor's suture(s) were tied around a loop of 8 high\u2010strength nonabsorbable sutures and pulled in line with the anchor at a rate of 1\u00a0mm\/s until failure. The following knotless anchors were tested: Stryker Knotilus 3.5, Arthrex Pushlock 2.9, Linvatec PopLok 2.8, Linvatec PopLok 3.3, ArthroCare SpeedLock HIP (3.4\u2010mm), and Smith &amp; Nephew Bioraptor Knotless 2.9. The standard knot tying Smith &amp; Nephew Bioraptor 2.9\u00a0mm served as a baseline for comparison.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Stiffness was highest in the Pushlock, the SpeedLock HIP, and Knotilus. At 1\u00a0mm displacement, the SpeedLock HIP exhibited significantly higher load than all other anchors, excluding the Pushlock and PopLok 3.3 (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0\u2264\u00a0.012 for all comparisons). Excluding the SpeedLock HIP and Knotilus, the Pushlock displayed significantly higher load than all other anchors at 2\u2010mm displacement (\n                      <jats:italic>P<\/jats:italic>\n                      \u2264 .015 for all comparisons). Maximum load was the highest for the Knotilus and Bioraptor knotted anchor (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .001 compared with all other anchors).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>All knotless suture anchors used in hip arthroscopy, except for the Knotilus 3.5, failed by suture pullout from the anchor. The 2 anchors with the highest maximum load, the Knotilus 3.5 and knotted Bioraptor 2.9, failed by suture failure; however, these anchors displayed the lowest stiffness and load at 1\u00a0mm displacement among all anchors tested. Stiffness and loads at clinically relevant displacements, not maximum load alone, may be most important in predicting anchor clinical performance during the early phases of labral healing.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance<\/jats:title>\n                    <jats:p>Knotless suture anchors tend to fail by suture pullout from the anchor, yet the stiffness of these constructs suggests that minimal displacement of the repair will occur under physiologic loads.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.arthro.2018.07.035","type":"journal-article","created":{"date-parts":[[2018,11,22]],"date-time":"2018-11-22T17:53:57Z","timestamp":1542909237000},"page":"70","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":13,"title":["Knotless Anchors in Acetabular Labral Repair: A Biomechanical Comparison"],"prefix":"10.1002","volume":"35","author":[{"given":"Marc R.","family":"Safran","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery Stanford University Stanford California U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony W.","family":"Behn","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Stanford University Stanford California U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Itamar B.","family":"Botser","sequence":"additional","affiliation":[{"name":"Rambam Medical Centre Haifa Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rodrigo","family":"Mardones","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery Clinica Las Condes Santiago Chile"},{"name":"Hip Surgery Unit Hospital Militar Santiago Chile"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2018,11,22]]},"reference":[{"key":"e_1_2_3_2_2","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-201006000-00006"},{"key":"e_1_2_3_3_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546507300258"},{"issue":"2","key":"e_1_2_3_4_2","doi-asserted-by":"crossref","first-page":"36","DOI":"10.2106\/JBJS.F.01123","article-title":"Treatment of femoro\u2010acetabular impingement: Preliminary results of labral refixation. Surgical technique","volume":"89","author":"Espinosa N.","year":"2007","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"e_1_2_3_5_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546511434578"},{"key":"e_1_2_3_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2007.01.017"},{"key":"e_1_2_3_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2011.02.016"},{"key":"e_1_2_3_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2013.01.028"},{"key":"e_1_2_3_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2008.03.006"},{"key":"e_1_2_3_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2016.11.022"},{"key":"e_1_2_3_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(93)90014-6"},{"key":"e_1_2_3_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2007.08.024"},{"key":"e_1_2_3_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.joca.2013.01.012"},{"key":"e_1_2_3_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/0883-5403(92)90052-R"},{"key":"e_1_2_3_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2016.09.031"},{"key":"e_1_2_3_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(00)90037-9"},{"key":"e_1_2_3_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2011.10.024"},{"key":"e_1_2_3_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2013.12.036"},{"key":"e_1_2_3_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2009.10.013"},{"key":"e_1_2_3_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2007.08.013"},{"key":"e_1_2_3_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2011.06.011"},{"key":"e_1_2_3_22_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546514568086"},{"key":"e_1_2_3_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.fas.2012.12.003"},{"key":"e_1_2_3_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2006.04.106"},{"key":"e_1_2_3_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2013.02.006"},{"key":"e_1_2_3_26_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.20856"}],"container-title":["Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806318306236?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806318306236?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2018.07.035","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.arthro.2018.07.035","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2018.07.035","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T09:29:37Z","timestamp":1773566977000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.arthro.2018.07.035"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11,22]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,1]]}},"alternative-id":["10.1016\/j.arthro.2018.07.035"],"URL":"https:\/\/doi.org\/10.1016\/j.arthro.2018.07.035","archive":["Portico"],"relation":{},"ISSN":["0749-8063","1526-3231"],"issn-type":[{"value":"0749-8063","type":"print"},{"value":"1526-3231","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,11,22]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Knotless Anchors in Acetabular Labral Repair: A Biomechanical Comparison","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy: The Journal of Arthroscopic & Related Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arthro.2018.07.035","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 by the Arthroscopy Association of North America","name":"copyright","label":"Copyright"}]}}