{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T00:13:49Z","timestamp":1789172029349,"version":"build-2803163510"},"reference-count":25,"publisher":"Wiley","issue":"12","license":[{"start":{"date-parts":[[2020,4,18]],"date-time":"2020-04-18T00:00:00Z","timestamp":1587168000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2020,4,18]],"date-time":"2020-04-18T00:00:00Z","timestamp":1587168000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2020,4,18]],"date-time":"2020-04-18T00:00:00Z","timestamp":1587168000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,4,18]],"date-time":"2020-04-18T00:00:00Z","timestamp":1587168000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2020,4,12]],"date-time":"2020-04-12T00:00:00Z","timestamp":1586649600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100008426","name":"DePuy Mitek","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008426","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100008426","name":"DePuy Mitek","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008426","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100008426","name":"DePuy Mitek","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008426","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100008426","name":"DePuy Mitek","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008426","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004331","name":"Johnson & Johnson","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004331","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["arthroscopyjournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate the biomechanical characteristics of recently introduced meniscal repair devices with a hand\u2010tied, inside\u2010out meniscal suture in a human meniscus model.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In detached adult human menisci, vertical longitudinal cuts were created 3 mm from the synovial\u2010meniscal junction, simulating a bucket\u2010handle meniscal tear. Each cut was repaired using a single device. Group 1 received a vertical mattress suture of No. 2\u20100 OrthoCord; group 2, TrueSpan device with PEEK (polyether ether ketone) anchors containing No. 2\u20100 OrthoCord suture; group 3, TrueSpan device with biodegradable poly\u2010lactide\u2013co\u2010glycolide (PLGA) anchors containing No. 2\u20100 OrthoCord suture; group 4, Meniscal Cinch II device; group 5, AIR meniscal repair device; and group 6, FasT\u2010Fix 360 device. All samples were preloaded at 5 N and cycled 200 times between 5 and 20 N. The specimens that survived cyclic loading were destructively tested at 12.5 mm\/s. Endpoints included maximum load, displacement, stiffness, and failure mode.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The mean failure loads were as follows: 95.8 N for OrthoCord suture, 87.1 N for TrueSpan with PEEK, 84.6 N for TrueSpan with PLGA, 48.6 N for Meniscal Cinch II, 72.3 N for AIR, and 68.1 N for FasT\u2010Fix 360. Repairs performed with OrthoCord suture (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .002) and both TrueSpan devices (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .03) but not the FasT\u2010Fix 360 device or AIR device were statistically significantly stronger than Meniscal Cinch II repairs. Mean cyclic displacement measured 1.1 mm for OrthoCord, 1.5 mm for TrueSpan with PEEK, 1.5 mm for TrueSpan with PLGA, 2.1 mm for Meniscal Cinch II, 1.1 mm for AIR, and 1.4 mm for FasT\u2010Fix 360. The Meniscal Cinch II device showed more displacement than all other devices (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .05). The FasT\u2010Fix 360, AIR, and Meniscal Cinch II devices failed by anchor pullout from the peripheral meniscus. OrthoCord and both TrueSpan devices failed by suture pulling through the bucket\u2010handle tissue.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>OrthoCord suture is stronger than the AIR, FasT\u2010Fix 360, and Meniscal Cinch II devices. The TrueSpan device with PEEK and TrueSpan device with PLGA are stronger than the Meniscal Cinch II device. The Meniscal Cinch II device failed during cyclic loading with greater cyclic displacement than the AIR device, FasT\u2010Fix 360 device, OrthoCord, and TrueSpan device with PEEK. The Meniscal Cinch II, AIR, and FasT\u2010Fix 360 devices failed by anchor pullout, whereas OrthoCord and both TrueSpan devices failed by suture pull\u2010through.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance<\/jats:title>\n                    <jats:p>Some newly introduced all\u2010inside meniscal repair devices show inferior failure strength compared with earlier versions that might adversely impact clinical outcomes.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.arthro.2020.03.036","type":"journal-article","created":{"date-parts":[[2020,4,18]],"date-time":"2020-04-18T10:31:42Z","timestamp":1587205902000},"page":"3001-3007","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":28,"title":["The Biomechanical Performance of the Latest All\u2010Inside Meniscal Repair Devices"],"prefix":"10.1002","volume":"36","author":[{"given":"F. Alan","family":"Barber","sequence":"first","affiliation":[{"name":"Plano Orthopedic Sports Medicine Center Plano Texas U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael S.","family":"Howard","sequence":"additional","affiliation":[{"name":"Plano Orthopedic Sports Medicine Center Plano Texas U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wasik","family":"Ashraf","sequence":"additional","affiliation":[{"name":"Crystal Run Healthcare New Windsor New York U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David B.","family":"Spenciner","sequence":"additional","affiliation":[{"name":"DePuy Synthes Mitek Sports Medicine Raynham Massachusetts U.S.A."},{"name":"Rensselaer Polytechnic Institute Troy New York U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2020,4,18]]},"reference":[{"key":"e_1_2_3_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.04.009"},{"key":"e_1_2_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.08.045"},{"key":"e_1_2_3_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.03.002"},{"key":"e_1_2_3_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.02.010"},{"key":"e_1_2_3_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.03.052"},{"key":"e_1_2_3_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2017.11.009"},{"key":"e_1_2_3_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(97)90120-1"},{"key":"e_1_2_3_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2018.11.056"},{"key":"e_1_2_3_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2010.09.010"},{"key":"e_1_2_3_11_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546516632504"},{"key":"e_1_2_3_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2016.08.008"},{"key":"e_1_2_3_13_2","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20080401-32"},{"key":"e_1_2_3_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(05)80095-7"},{"key":"e_1_2_3_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2009.03.020"},{"key":"e_1_2_3_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2014.08.027"},{"key":"e_1_2_3_17_2","first-page":"663","article-title":"The mechanical function of the meniscus, experiments on cadaveric pig knee\u2010joints","volume":"46","author":"Jaspers P.","year":"1980","journal-title":"Acta Orthop Belg"},{"key":"e_1_2_3_18_2","first-page":"165","article-title":"Morphology and water and lipid contents of stifle menisci of growing swine","volume":"56","author":"Nakano T.","year":"1992","journal-title":"Can J Vet Res"},{"key":"e_1_2_3_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2005.12.009"},{"key":"e_1_2_3_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(97)90008-6"},{"key":"e_1_2_3_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2011.11.020"},{"key":"e_1_2_3_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2003.11.010"},{"key":"e_1_2_3_23_2","doi-asserted-by":"publisher","DOI":"10.1053\/jars.2000.4819"},{"key":"e_1_2_3_24_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546506290667"},{"key":"e_1_2_3_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2005.09.001"},{"key":"e_1_2_3_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.09.030"}],"container-title":["Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806320303133?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806320303133?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2020.03.036","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.arthro.2020.03.036","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2020.03.036","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T09:23:33Z","timestamp":1773566613000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.arthro.2020.03.036"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,18]]},"references-count":25,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["10.1016\/j.arthro.2020.03.036"],"URL":"https:\/\/doi.org\/10.1016\/j.arthro.2020.03.036","archive":["Portico"],"relation":{},"ISSN":["0749-8063","1526-3231"],"issn-type":[{"value":"0749-8063","type":"print"},{"value":"1526-3231","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,18]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The Biomechanical Performance of the Latest All-Inside Meniscal Repair Devices","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy: The Journal of Arthroscopic & Related Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arthro.2020.03.036","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 The Author(s). Published by Elsevier on behalf of the Arthroscopy Association of North America.","name":"copyright","label":"Copyright"}]}}