{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T18:48:04Z","timestamp":1773600484315,"version":"3.50.1"},"reference-count":2,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T00:00:00Z","timestamp":1614556800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["arthroscopyjournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy"],"published-print":{"date-parts":[[2021,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The minimal clinically important difference is a relatively new method to evaluate outcomes after surgery, defined as the lowest value of change in the outcome score that results in a perceived clinical improvement. There is no clear delineation of use for this metric, resulting in a heterogeneous application in hip arthroscopy research, making comparisons with other studies difficult. Cohort\u2010specific values calculated using an anchor\u2010based method are best.<\/jats:p>","DOI":"10.1016\/j.arthro.2020.12.232","type":"journal-article","created":{"date-parts":[[2021,3,2]],"date-time":"2021-03-02T02:04:00Z","timestamp":1614650640000},"page":"1038-1039","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["<i>Editorial Commentary:<\/i>\n                    Large Heterogeneity of Minimal Clinically Important Difference Utilization in Hip Arthroscopy Studies: Where Do We Go From Here?"],"prefix":"10.1002","volume":"37","author":[{"given":"Timothy J.","family":"Jackson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2021,3,1]]},"reference":[{"key":"e_1_2_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2020.10.050"},{"key":"e_1_2_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.12.002"}],"container-title":["Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806321000062?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806321000062?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2020.12.232","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.arthro.2020.12.232","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2020.12.232","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T08:58:43Z","timestamp":1773565123000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.arthro.2020.12.232"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3]]},"references-count":2,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,3]]}},"alternative-id":["10.1016\/j.arthro.2020.12.232"],"URL":"https:\/\/doi.org\/10.1016\/j.arthro.2020.12.232","archive":["Portico"],"relation":{},"ISSN":["0749-8063","1526-3231"],"issn-type":[{"value":"0749-8063","type":"print"},{"value":"1526-3231","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Editorial Commentary: Large Heterogeneity of Minimal Clinically Important Difference Utilization in Hip Arthroscopy Studies: Where Do We Go From Here?","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy: The Journal of Arthroscopic & Related Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arthro.2020.12.232","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"simple-article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 Published by Elsevier on behalf of the Arthroscopy Association of North America","name":"copyright","label":"Copyright"}]}}