{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T10:51:20Z","timestamp":1773571880220,"version":"3.50.1"},"reference-count":5,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T00:00:00Z","timestamp":1693526400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T00:00:00Z","timestamp":1693526400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T00:00:00Z","timestamp":1693526400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T00:00:00Z","timestamp":1693526400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100021976","name":"Medical Technology Enterprise Consortium","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100021976","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000090","name":"Congressionally Directed Medical Research Programs","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000090","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100011549","name":"American Orthopaedic Society for Sports Medicine","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100011549","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["arthroscopyjournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy"],"published-print":{"date-parts":[[2023,9]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>To improve the outcomes of arthroscopic rotator cuff (RC) repair, it is important to achieve tendon\u2010to\u2010bone healing at the repair site. Healed repairs are more likely to restore shoulder strength and lead to higher magnitudes of satisfaction. Patches or grafts that can be either secured to the bursal surface of the RC or interposed between the RC tendon and greater tuberosity at the time of repair have been described as adjuncts to RC repair. A cancellous, biphasic allograft tissue composed of 2 layers (calcified to promote osseointegration and demineralized to support soft\u2010tissue ingrowth) has been shown to be safe in an ovine model, without a harmful inflammatory or foreign body response. Human trials may be a reasonable next step.<\/jats:p>","DOI":"10.1016\/j.arthro.2023.04.008","type":"journal-article","created":{"date-parts":[[2023,8,3]],"date-time":"2023-08-03T18:44:54Z","timestamp":1691088294000},"page":"1998-1999","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["<i>Editorial Commentary:<\/i>\n                    A Biphasic (Calcified and Demineralized), Cancellous, Interpositional Allograft Augmenting Rotator Cuff Repair in an Ovine Model Does Not Show Harmful Inflammation or Foreign Body Reaction"],"prefix":"10.1002","volume":"39","author":[{"given":"Andrew J.","family":"Sheean","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2023,9,1]]},"reference":[{"key":"e_1_2_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.02.048"},{"key":"e_1_2_2_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-017-5251-7"},{"key":"e_1_2_2_4_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546516652900"},{"key":"e_1_2_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2009.07.023"},{"key":"e_1_2_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2023.03.018"}],"container-title":["Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806323003316?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806323003316?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2023.04.008","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.arthro.2023.04.008","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2023.04.008","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T09:22:35Z","timestamp":1773566555000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.arthro.2023.04.008"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9]]},"references-count":5,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2023,9]]}},"alternative-id":["10.1016\/j.arthro.2023.04.008"],"URL":"https:\/\/doi.org\/10.1016\/j.arthro.2023.04.008","archive":["Portico"],"relation":{},"ISSN":["0749-8063","1526-3231"],"issn-type":[{"value":"0749-8063","type":"print"},{"value":"1526-3231","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Editorial Commentary: A Biphasic (Calcified and Demineralized), Cancellous, Interpositional Allograft Augmenting Rotator Cuff Repair in an Ovine Model Does Not Show Harmful Inflammation or Foreign Body Reaction","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy: The Journal of Arthroscopic & Related Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arthro.2023.04.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"simple-article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 by the Arthroscopy Association of North America","name":"copyright","label":"Copyright"}]}}