{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T17:58:44Z","timestamp":1791568724708,"version":"4.3.4"},"reference-count":33,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T00:00:00Z","timestamp":1694736000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T00:00:00Z","timestamp":1694736000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T00:00:00Z","timestamp":1694736000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T00:00:00Z","timestamp":1694736000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["arthroscopyjournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy"],"published-print":{"date-parts":[[2024,2]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To compare the clinical outcomes and tendon integrity after rotator cuff repair combined with anterior cable reconstruction (ACR) using the proximal biceps tendon and patch augmentation (PA) using a human dermal allograft (HDA) in a large retracted anterior rotator cuff tear.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Patients who underwent arthroscopic rotator cuff repair with 2 different augmentation procedures between January 2017 and December 2020 were enrolled. The inclusion criteria were patients who were treated by arthroscopic rotator cuff repair with ACR using the proximal biceps tendon (ACR group) or patch augmentation using a an HDA (PA group) and follow\u2010up for at least 2 years. Clinical outcomes were assessed using American Shoulder and Elbow Surgeons (ASES) score, Constant score, and the number of patients who achieved minimal clinically important differences (MCID). Magnetic resonance imaging was performed to evaluate tendon integrity after surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 92 patients were enrolled (ACR group\u00a0= 55 patients and PA group\u00a0= 37 patients). The mean ASES and Constant scores significantly improved in the ACR group (68.8 \u00b1 15.3 and 58.4 \u00b1 16.9 before surgery vs 91.4 \u00b1 6.3 and 87.8 \u00b1 6.0 after surgery,\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .001) and in the PA group (63.7\u00a0\u00b1\u00a016.7 and 57.9 \u00b1 15.4 before surgery vs 93.1 \u00b1 6.3 and 88.3 \u00b1 6.2 after surgery,\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .001). Overall, 78 patients (84.8%) achieved the MCID with 81.8% in the ACR group and 89.2% in the PA group, with no significant differences between the 2 groups (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .638). Ten patients (18.2%) had retear in the ACR group, and three patients (8.1%) had retear in the PA group (\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0= .174).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In large retracted anterior rotator cuff tears, both augmentation techniques using biceps tendon autograft and HDA provided satisfactory clinical outcomes that achieved the MCID in 84.8%, range of motion restoration, and lower retear rates with no significant differences between the two groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence<\/jats:title>\n                    <jats:p>Level III, retrospective case\u2010control study.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.arthro.2023.08.077","type":"journal-article","created":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T03:04:19Z","timestamp":1694747059000},"page":"294-302","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":23,"title":["No Difference In Clinical Outcomes Following Repair of Large Retracted Anterior Rotator Cuff Tears Using Patch Augmentation With Human Dermal Allograft Versus Anterior Cable Reconstruction With Biceps Tendon Autograft"],"prefix":"10.1002","volume":"40","author":[{"given":"Seong Hun","family":"Kim","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery National Health Insurance Service Ilsan Hospital Gyeonggi Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sang\u2010Jin","family":"Shin","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery College of Medicine Ewha Womans University Seoul Hospital Seoul Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2023,9,15]]},"reference":[{"key":"e_1_2_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2015.03.028"},{"key":"e_1_2_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2009.07.009"},{"key":"e_1_2_2_4_2","doi-asserted-by":"publisher","DOI":"10.1302\/2058-5241.1.160005"},{"key":"e_1_2_2_5_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546513497565"},{"key":"e_1_2_2_6_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546517720198"},{"key":"e_1_2_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2018.05.012"},{"key":"e_1_2_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2022.03.008"},{"key":"e_1_2_2_9_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-022-07112-1"},{"key":"e_1_2_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2020.09.011"},{"key":"e_1_2_2_11_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.L.00784"},{"key":"e_1_2_2_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00064-021-00754-3"},{"key":"e_1_2_2_13_2","first-page":"833","article-title":"Rotator cuff repair with patch augmentation: What do we know?","volume":"10","author":"Cobb T.E.","year":"2022","journal-title":"Arch Bone Jt Surg"},{"key":"e_1_2_2_14_2","doi-asserted-by":"publisher","DOI":"10.1177\/03635465211015194"},{"key":"e_1_2_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2022.08.004"},{"key":"e_1_2_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(05)80186-0"},{"key":"e_1_2_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2008.09.012"},{"key":"e_1_2_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1058-2746(99)90097-6"},{"key":"e_1_2_2_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199407000-00014"},{"key":"e_1_2_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2017.10.042"},{"key":"e_1_2_2_21_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546517709772"},{"key":"e_1_2_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2011.06.038"},{"key":"e_1_2_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.eats.2022.08.015"},{"key":"e_1_2_2_24_2","doi-asserted-by":"publisher","DOI":"10.4055\/cios21135"},{"key":"e_1_2_2_25_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546515625044"},{"key":"e_1_2_2_26_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546518774762"},{"key":"e_1_2_2_27_2","doi-asserted-by":"publisher","DOI":"10.1177\/23259671211071146"},{"key":"e_1_2_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2015.02.032"},{"key":"e_1_2_2_29_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-022-06975-8"},{"key":"e_1_2_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2009.07.010"},{"key":"e_1_2_2_31_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546513518581"},{"key":"e_1_2_2_32_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546517695234"},{"key":"e_1_2_2_33_2","doi-asserted-by":"publisher","DOI":"10.1067\/mse.2000.109385"},{"key":"e_1_2_2_34_2","doi-asserted-by":"publisher","DOI":"10.3390\/bioengineering7020039"}],"container-title":["Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806323007636?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806323007636?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2023.08.077","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.arthro.2023.08.077","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2023.08.077","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T09:12:32Z","timestamp":1773565952000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.arthro.2023.08.077"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,15]]},"references-count":33,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,2]]}},"alternative-id":["10.1016\/j.arthro.2023.08.077"],"URL":"https:\/\/doi.org\/10.1016\/j.arthro.2023.08.077","archive":["Portico"],"relation":{},"ISSN":["0749-8063","1526-3231"],"issn-type":[{"value":"0749-8063","type":"print"},{"value":"1526-3231","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,15]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"No Difference In Clinical Outcomes Following Repair of Large Retracted Anterior Rotator Cuff Tears Using Patch Augmentation With Human Dermal Allograft Versus Anterior Cable Reconstruction With Biceps Tendon Autograft","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy: The Journal of Arthroscopic & Related Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arthro.2023.08.077","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 by the Arthroscopy Association of North America","name":"copyright","label":"Copyright"}]}}