{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T10:33:19Z","timestamp":1773570799887,"version":"3.50.1"},"reference-count":9,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2024,2,1]],"date-time":"2024-02-01T00:00:00Z","timestamp":1706745600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2024,2,1]],"date-time":"2024-02-01T00:00:00Z","timestamp":1706745600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2024,2,1]],"date-time":"2024-02-01T00:00:00Z","timestamp":1706745600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,2,1]],"date-time":"2024-02-01T00:00:00Z","timestamp":1706745600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["arthroscopyjournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy"],"published-print":{"date-parts":[[2024,2]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Chronic retracted rotator cuff tears are difficult entities to treat. L\u2010shaped tears are a particular subset of such rotator cuff tears that pose challenges for surgeons attempting to reduce the supraspinatus tendon back to the greater tuberosity. Lack of full coverage of the tuberosity, need for medialization of the tendon, undue tension, and incomplete reconstitution of the rotator cable are some of the reasons L\u2010shaped retracted tears of the supraspinatus can be challenging. Anterior cable reconstruction (ACR) is a technique that has gained increasing recent popularity, as is the use of patch augmentation. The long head of the biceps tendon is often readily available for use in ACR, but when it isn\u2019t, patch augmentation is an option for partially repairable rotator cuff tears. These produce similar postoperative improvements in range of motion as well as Constant and American Shoulder and Elbow Surgeons scores, but comparison to partial repair is still unknown.<\/jats:p>","DOI":"10.1016\/j.arthro.2023.10.030","type":"journal-article","created":{"date-parts":[[2024,1,29]],"date-time":"2024-01-29T19:40:44Z","timestamp":1706557244000},"page":"303-304","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["<i>Editorial Commentary:<\/i>\n                    Augmentation With Allograft Patch Results in Similar Outcomes to Anterior Cable Reconstruction With Autograft Biceps Tendon for Chronic, Retracted, Anterior, L\u2010Shaped Supraspinatus Tears"],"prefix":"10.1002","volume":"40","author":[{"given":"Timothy","family":"Lin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2024,2,1]]},"reference":[{"key":"e_1_2_3_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcot.2021.04.005"},{"key":"e_1_2_3_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2022.09.011"},{"key":"e_1_2_3_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2022.03.008"},{"key":"e_1_2_3_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2023.08.077"},{"key":"e_1_2_3_6_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-016-4105-2"},{"key":"e_1_2_3_7_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40798-019-0186-z"},{"key":"e_1_2_3_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2021.102894"},{"key":"e_1_2_3_9_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-023-06174-7"},{"key":"e_1_2_3_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2015.06.006"}],"container-title":["Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806323008745?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806323008745?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2023.10.030","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.arthro.2023.10.030","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2023.10.030","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T09:12:44Z","timestamp":1773565964000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.arthro.2023.10.030"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2]]},"references-count":9,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,2]]}},"alternative-id":["10.1016\/j.arthro.2023.10.030"],"URL":"https:\/\/doi.org\/10.1016\/j.arthro.2023.10.030","archive":["Portico"],"relation":{},"ISSN":["0749-8063","1526-3231"],"issn-type":[{"value":"0749-8063","type":"print"},{"value":"1526-3231","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Editorial Commentary: Augmentation With Allograft Patch Results in Similar Outcomes to Anterior Cable Reconstruction With Autograft Biceps Tendon for Chronic, Retracted, Anterior, L-Shaped Supraspinatus Tears","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy: The Journal of Arthroscopic & Related Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arthro.2023.10.030","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"https:\/\/doi.org\/10.1016\/j.arthro.2023.08.077","name":"associatedlink","label":"CrossRef DOI link to the associated document"},{"value":"simple-article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 by the Arthroscopy Association of North America","name":"copyright","label":"Copyright"}]}}