{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T10:48:29Z","timestamp":1773571709567,"version":"3.50.1"},"reference-count":28,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2024,12,11]],"date-time":"2024-12-11T00:00:00Z","timestamp":1733875200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2024,12,11]],"date-time":"2024-12-11T00:00:00Z","timestamp":1733875200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2024,12,11]],"date-time":"2024-12-11T00:00:00Z","timestamp":1733875200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,12,11]],"date-time":"2024-12-11T00:00:00Z","timestamp":1733875200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100019400","name":"CONMED Corporation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100019400","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["arthroscopyjournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy"],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To assess the variability in graft biomechanical properties of an acellular human dermal matrix patch.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A total of 22 strips obtained from 6 separate graft specimens (AlloPatch HD) were tested. Load elongation properties after cyclic loading, including ultimate load at break, energy at break, and extension at break, were tested and compared by graft thickness. Suture pull\u2010out testing using a simple vertical stitch suture retention test was performed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      There was a significant, strong positive correlation between graft thickness and ultimate load to failure, energy at break, and extension at break (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .01). The association between direction of graft in relation to skin tension lines and ultimate load to failure was also significant (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .034). The difference in ultimate load to failure from the extremes of graft thickness in this study (1.1 mm vs 3.2 mm) was almost 4\u2010fold (104 N\/mm\n                      <jats:sup>2<\/jats:sup>\n                      vs 402 N\/mm\n                      <jats:sup>2<\/jats:sup>\n                      ). The suture pull\u2010out testing of 10 dermal graft test strips showed that once the graft thickness reached a threshold thickness of 2 mm, the mode of failure changed from cutting through the graft vertically to tearing the graft diagonally.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The tested dermal allograft patch shows great variability in thickness within and between individual patches. This study has revealed that grafts thicker than 2 mm and those used in parallel to skin tension lines exhibit a higher ultimate load to failure. Furthermore, graft thickness over 2 mm influenced the method of suture failure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical Relevance<\/jats:title>\n                    <jats:p>Caution should be exercised when using grafts less than 2 mm due to lower ultimate load to failure and suture pull\u2010out. Marking the patches in accordance with skin tension lines would help determine the ideal orientation of insertion.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.arthro.2024.11.095","type":"journal-article","created":{"date-parts":[[2024,12,12]],"date-time":"2024-12-12T01:39:03Z","timestamp":1733967543000},"page":"2544-2550","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Dermal Graft Thickness Over 2 mm and Grafts Oriented Parallel to Skin Tension Lines Increased Graft Strength and Suture Retention: A Biomechanical Study"],"prefix":"10.1002","volume":"41","author":[{"given":"William G.","family":"Blakeney","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery Royal Perth Hospital Perth Australia"},{"name":"Department of Surgery University of Western Australia Perth Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aysha Abu","family":"Sharifa","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Royal Perth Hospital Perth Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Graham","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Royal Perth Hospital Perth Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alan","family":"Kop","sequence":"additional","affiliation":[{"name":"Department of Medical Engineering and Physics Centre for Implant Technology and Retrieval Analysis Royal Perth Hospital Perth Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2024,12,11]]},"reference":[{"key":"e_1_2_3_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/ans.13691"},{"key":"e_1_2_3_3_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.D.02035"},{"key":"e_1_2_3_4_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546507313574"},{"key":"e_1_2_3_5_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200706000-00013"},{"key":"e_1_2_3_6_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.F.00512"},{"key":"e_1_2_3_7_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546510382835"},{"key":"e_1_2_3_8_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.G.00677"},{"key":"e_1_2_3_9_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546514525336"},{"key":"e_1_2_3_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2011.06.038"},{"key":"e_1_2_3_11_2","doi-asserted-by":"publisher","DOI":"10.1177\/2325967115587495"},{"key":"e_1_2_3_12_2","doi-asserted-by":"publisher","DOI":"10.1530\/EOR-21-0070"},{"key":"e_1_2_3_13_2","doi-asserted-by":"publisher","DOI":"10.1113\/jphysiol.2009.172080"},{"key":"e_1_2_3_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2009.10.020"},{"key":"e_1_2_3_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.08.026"},{"key":"e_1_2_3_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2009.05.012"},{"key":"e_1_2_3_17_2","article-title":"Prevention of hyper\u2010 and hypotrophic scars through surgical incisions in the direction of the \u201cmain folding lines\u201d of the skin","volume":"7","author":"Lemperle G.","year":"2020","journal-title":"Plast Aesthetic Res"},{"key":"e_1_2_3_18_2","first-page":"151","article-title":"Biologics to improve healing in large and massive rotator cuff tears: A critical review","volume":"12","author":"Goldenberg B.T.","year":"2020","journal-title":"Orthop Res Rev"},{"key":"e_1_2_3_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2017.08.265"},{"key":"e_1_2_3_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2007.07.013"},{"key":"e_1_2_3_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2006.03.016"},{"key":"e_1_2_3_22_2","doi-asserted-by":"publisher","DOI":"10.4103\/0973-6042.96992"},{"key":"e_1_2_3_23_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.sart.2006.11.017"},{"key":"e_1_2_3_24_2","doi-asserted-by":"publisher","DOI":"10.1007\/s12306-011-0141-8"},{"key":"e_1_2_3_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2011.08.016"},{"key":"e_1_2_3_26_2","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2009.2033464"},{"key":"e_1_2_3_27_2","doi-asserted-by":"publisher","DOI":"10.1533\/9781845696801.1.179"},{"key":"e_1_2_3_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.asmr.2021.06.015"},{"key":"e_1_2_3_29_2","doi-asserted-by":"publisher","DOI":"10.1177\/03635465241253266"}],"container-title":["Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806324010284?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806324010284?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2024.11.095","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.arthro.2024.11.095","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2024.11.095","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T09:21:04Z","timestamp":1773566464000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.arthro.2024.11.095"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,11]]},"references-count":28,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2025,7]]}},"alternative-id":["10.1016\/j.arthro.2024.11.095"],"URL":"https:\/\/doi.org\/10.1016\/j.arthro.2024.11.095","archive":["Portico"],"relation":{},"ISSN":["0749-8063","1526-3231"],"issn-type":[{"value":"0749-8063","type":"print"},{"value":"1526-3231","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Dermal Graft Thickness Over 2 mm and Grafts Oriented Parallel to Skin Tension Lines Increased Graft Strength and Suture Retention: A Biomechanical Study","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy: The Journal of Arthroscopic & Related Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arthro.2024.11.095","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Crown Copyright \u00a9 2024 Published by Elsevier Inc. on behalf of the Arthroscopy Association of North America. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}