{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T03:43:57Z","timestamp":1793331837348,"version":"4.5.0"},"reference-count":33,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T00:00:00Z","timestamp":1742947200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T00:00:00Z","timestamp":1742947200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T00:00:00Z","timestamp":1742947200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T00:00:00Z","timestamp":1742947200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["arthroscopyjournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Arthroscopy"],"published-print":{"date-parts":[[2025,9]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To investigate the structural outcomes of arthroscopic repair of traumatic rotator cuff (RC) tears and analyze the factors related to retears, focusing on tendon quality observed using arthroscopy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This retrospective study included patients who had undergone arthroscopic repair of traumatic full\u2010thickness RC tears between 2014 and 2021. Traumatic RC tears were defined as the sudden onset or worsening of shoulder pain or function within 3 years after a slip or fall. Gross tendon quality was assessed using arthroscopic imaging and categorized as none (grade 0), mild (grade 1), or advanced (grade 2). RC retear was assessed using magnetic resonance imaging at 6 months and clinically evaluated at least 1 year after surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 121 patients were included in the study, and the RC retear rate was 27.3% (33 of 121). RC retears were significantly associated with supraspinatus (SSP) medial retraction (\n                      <jats:italic>P<\/jats:italic>\n                      = .015) and atrophy with fatty infiltration (\n                      <jats:italic>P<\/jats:italic>\n                      = .010) on magnetic resonance imaging, as well as tendon deterioration (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .001) and anterior rotator cable rupture (\n                      <jats:italic>P<\/jats:italic>\n                      = .034) observed during arthroscopy. On multivariable analysis, advanced tendon deterioration (grade 1 vs grade 0: odds ratio [OR], 0.3; 95% confidence interval [CI], 0.1\u20101.3,\n                      <jats:italic>P<\/jats:italic>\n                      = .117; grade 2 vs grade 0: OR, 6.3; 95% CI, 1.9\u201021.2;\n                      <jats:italic>P<\/jats:italic>\n                      = .003) and the absence of initial pseudoparesis (OR, 0.1; 95% CI, 0.02\u20101.0;\n                      <jats:italic>P<\/jats:italic>\n                      = .045) were identified as significant predictors of retear. Additionally, SSP medial retraction (OR, 1.5; 95% CI, 1.0\u20102.2;\n                      <jats:italic>P<\/jats:italic>\n                      = .056) was identified as a potential predictor of retear. The final visual analog scale score for function was significantly lower in the RC retear group than in the intact group (7.1 \u00b1 1.8 vs 8.0 \u00b1 1.2,\n                      <jats:italic>P<\/jats:italic>\n                      = .013), whereas other shoulder function parameters were similar between the groups. Final shoulder function was not significantly affected by tendon quality.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Gross tendon quality, as assessed during arthroscopy, and SSP medial retraction, as well as the absence of initial pseudoparesis, were predictors of retear after the repair of traumatic RC tears. Intraoperative assessment of tendon quality is important for predicting surgical outcomes of traumatic RC tear repair.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence<\/jats:title>\n                    <jats:p>Level IV, retrospective case series.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.arthro.2025.03.037","type":"journal-article","created":{"date-parts":[[2025,3,28]],"date-time":"2025-03-28T20:19:55Z","timestamp":1743193195000},"page":"3510","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"title":["Deteriorated Quality and Medial Retraction of Tendon After Acute Traumatic Rotator Cuff Tear Are Predictors of Retear After Arthroscopic Repair"],"prefix":"10.1002","volume":"41","author":[{"given":"Su Cheol","family":"Kim","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery Samsung Medical Center Sungkyunkwan University School of Medicine Seoul Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyun Gon","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery Korea University Ansan Hospital Ansan Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jong Hyun","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Samsung Medical Center Sungkyunkwan University School of Medicine Seoul Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seung Je","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Samsung Medical Center Sungkyunkwan University School of Medicine Seoul Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sang Min","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Samsung Medical Center Sungkyunkwan University School of Medicine Seoul Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jae Chul","family":"Yoo","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Samsung Medical Center Sungkyunkwan University School of Medicine Seoul Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,3,26]]},"reference":[{"key":"e_1_2_4_2_1","doi-asserted-by":"publisher","DOI":"10.5397\/cise.2023.00430"},{"key":"e_1_2_4_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-021-06732-3"},{"key":"e_1_2_4_4_1","doi-asserted-by":"publisher","DOI":"10.1177\/03635465231189201"},{"key":"e_1_2_4_5_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-023-06617-1"},{"key":"e_1_2_4_6_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546518810763"},{"key":"e_1_2_4_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2023.03.027"},{"key":"e_1_2_4_8_1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.101B5.BJJ-2018-0867.R1"},{"key":"e_1_2_4_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2016.09.032"},{"key":"e_1_2_4_10_1","doi-asserted-by":"publisher","DOI":"10.1177\/23259671221133110"},{"key":"e_1_2_4_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2021.03.134"},{"key":"e_1_2_4_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2015.05.043"},{"key":"e_1_2_4_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-022-06884-w"},{"key":"e_1_2_4_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2014.08.015"},{"key":"e_1_2_4_15_1","doi-asserted-by":"crossref","unstructured":"PatteD.. Classification of rotator cuff lesions.Clin Orthop Relat Res1990;81\u201386.","DOI":"10.1097\/00003086-199005000-00012"},{"key":"e_1_2_4_16_1","doi-asserted-by":"publisher","DOI":"10.1177\/03635465231203702"},{"key":"e_1_2_4_17_1","doi-asserted-by":"crossref","unstructured":"GoutallierD. PostelJ.M. BernageauJ. LavauL. VoisinM.C.. Fatty muscle degeneration in cuff ruptures. Pre\u2010 and postoperative evaluation by CT scan.Clin Orthop Relat Res1994;78\u201383.","DOI":"10.1097\/00003086-199407000-00014"},{"key":"e_1_2_4_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2005.08.011"},{"key":"e_1_2_4_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2017.08.009"},{"key":"e_1_2_4_20_1","doi-asserted-by":"publisher","DOI":"10.5397\/cise.2023.00514"},{"key":"e_1_2_4_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2018.02.013"},{"key":"e_1_2_4_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2008.12.015"},{"key":"e_1_2_4_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1058-2746(09)80019-0"},{"key":"e_1_2_4_24_1","doi-asserted-by":"crossref","unstructured":"ConstantC.R. MurleyA.H.. A clinical method of functional assessment of the shoulder.Clin Orthop Relat Res1987;160\u2013164.","DOI":"10.1097\/00003086-198701000-00023"},{"key":"e_1_2_4_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2012.06.024"},{"key":"e_1_2_4_26_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546514561004"},{"key":"e_1_2_4_27_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546512462677"},{"key":"e_1_2_4_28_1","first-page":"10","article-title":"Prognostic factors affecting structural integrity after arthroscopic rotator cuff repair: A clinical and histological study","volume":"26","author":"Wang P.W.","year":"2023","journal-title":"Clin Shoulder Elb"},{"key":"e_1_2_4_29_1","doi-asserted-by":"publisher","DOI":"10.1530\/EOR-21-0069"},{"key":"e_1_2_4_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2017.02.024"},{"key":"e_1_2_4_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2018.08.048"},{"key":"e_1_2_4_32_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546511399865"},{"key":"e_1_2_4_33_1","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.L.00708"},{"key":"e_1_2_4_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2023.10.046"}],"container-title":["Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806325002336?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0749806325002336?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2025.03.037","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.arthro.2025.03.037","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.arthro.2025.03.037","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T08:49:08Z","timestamp":1773564548000},"score":1,"resource":{"primary":{"URL":"https:\/\/arthroscopyjournals.onlinelibrary.wiley.com\/doi\/10.1016\/j.arthro.2025.03.037"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,26]]},"references-count":33,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2025,9]]}},"alternative-id":["10.1016\/j.arthro.2025.03.037"],"URL":"https:\/\/doi.org\/10.1016\/j.arthro.2025.03.037","archive":["Portico"],"relation":{},"ISSN":["0749-8063","1526-3231"],"issn-type":[{"value":"0749-8063","type":"print"},{"value":"1526-3231","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,26]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Deteriorated Quality and Medial Retraction of Tendon After Acute Traumatic Rotator Cuff Tear Are Predictors of Retear After Arthroscopic Repair","name":"articletitle","label":"Article Title"},{"value":"Arthroscopy: The Journal of Arthroscopic & Related Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.arthro.2025.03.037","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 by the Arthroscopy Association of North America","name":"copyright","label":"Copyright"}]}}