{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T14:52:36Z","timestamp":1762008756883,"version":"build-2065373602"},"reference-count":20,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2018,4,1]],"date-time":"2018-04-01T00:00:00Z","timestamp":1522540800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,4,1]],"date-time":"2018-04-01T00:00:00Z","timestamp":1522540800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2018,2,22]],"date-time":"2018-02-22T00:00:00Z","timestamp":1519257600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology"],"published-print":{"date-parts":[[2018,4]]},"DOI":"10.1016\/j.asmart.2018.01.002","type":"journal-article","created":{"date-parts":[[2018,3,8]],"date-time":"2018-03-08T00:35:08Z","timestamp":1520469308000},"page":"5-11","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"special_numbering":"C","title":["Evaluating different closed loop graft preparation technique for tibial suspensory fixation in ACL reconstruction using TightRope\u2122"],"prefix":"10.1016","volume":"12","author":[{"given":"Takahisa","family":"Sasho","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshihide","family":"Sasaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroko","family":"Hoshi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryuichiro","family":"Akagi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takahiro","family":"Enomoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2475-8409","authenticated-orcid":false,"given":"Yusuke","family":"Sato","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryosuke","family":"Nakagawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masamichi","family":"Tahara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoshi","family":"Yamaguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.asmart.2018.01.002_bib1","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1016\/j.arthro.2008.07.010","article-title":"Graft tensioning in anterior cruciate ligament reconstruction: a systematic review of randomized controlled trials","volume":"25","author":"Arneja","year":"2009","journal-title":"Arthroscopy"},{"key":"10.1016\/j.asmart.2018.01.002_bib2","doi-asserted-by":"crossref","first-page":"934","DOI":"10.1016\/j.arthro.2013.01.021","article-title":"Initial graft tension and the effect on postoperative patient functional outcomes in anterior cruciate ligament reconstruction","volume":"29","author":"Kirwan","year":"2013","journal-title":"Arthroscopy"},{"key":"10.1016\/j.asmart.2018.01.002_bib3","doi-asserted-by":"crossref","first-page":"2892","DOI":"10.1007\/s00167-015-3552-5","article-title":"Effect of fixation angle and graft tension in double-bundle anterior cruciate ligament reconstruction on knee biomechanics","volume":"24","author":"Sasaki","year":"2015","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.asmart.2018.01.002_bib4","doi-asserted-by":"crossref","first-page":"1756","DOI":"10.1016\/j.arthro.2015.03.012","article-title":"Effect of initial graft tension on knee stability and graft tension pattern in double-bundle anterior cruciate ligament reconstruction","volume":"31","author":"Koga","year":"2015","journal-title":"Arthroscopy"},{"key":"10.1016\/j.asmart.2018.01.002_bib5","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1016\/j.arthro.2011.02.008","article-title":"All-inside anterior cruciate ligament graft-link technique: second-generation, no-incision anterior cruciate ligament reconstruction","volume":"27","author":"Lubowitz","year":"2011","journal-title":"Arthroscopy"},{"key":"10.1016\/j.asmart.2018.01.002_bib6","doi-asserted-by":"crossref","first-page":"754","DOI":"10.1007\/s00776-013-0427-9","article-title":"Prospective clinical comparisons of semitendinosus versus semitendinosus and gracilis tendon autografts for anatomic double-bundle anterior cruciate ligament reconstruction","volume":"18","author":"Inagaki","year":"2013","journal-title":"J\u00a0Orthop Sci"},{"key":"10.1016\/j.asmart.2018.01.002_bib7","doi-asserted-by":"crossref","first-page":"1222","DOI":"10.1007\/s00167-014-2950-4","article-title":"Outcome of anatomical double-bundle ACL reconstruction using hamstring tendons via an outside-in approach","volume":"23","author":"Amano","year":"2015","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.asmart.2018.01.002_bib8","doi-asserted-by":"crossref","first-page":"1662","DOI":"10.1016\/j.arthro.2010.05.013","article-title":"Krackow locking stitch versus locking premanufactured loop stitch for soft-tissue fixation: a biomechanical study","volume":"26","author":"White","year":"2010","journal-title":"Arthroscopy"},{"key":"10.1016\/j.asmart.2018.01.002_bib9","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1007\/s00167-011-1619-5","article-title":"Mechanical assessment of two different methods of tripling hamstring tendons when using suspensory fixation","volume":"20","author":"Snow","year":"2012","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.asmart.2018.01.002_bib10","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1177\/0363546512469875","article-title":"Femoral cortical suspension devices for soft tissue anterior cruciate ligament reconstruction: a comparative biomechanical study","volume":"41","author":"Petre","year":"2013","journal-title":"Am J Sports Med"},{"key":"10.1016\/j.asmart.2018.01.002_bib11","doi-asserted-by":"crossref","first-page":"909","DOI":"10.3928\/0147-7447-19880601-11","article-title":"Ligament-tendon fixation: analysis of a new stitch and comparison with standard techniques","volume":"11","author":"Krackow","year":"1988","journal-title":"Orthopedics"},{"key":"10.1016\/j.asmart.2018.01.002_bib12","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1016\/j.arthro.2011.10.014","article-title":"The modified finger-trap suture technique: a biomechanical comparison of a novel suture technique for graft fixation","volume":"28","author":"Su","year":"2012","journal-title":"Arthroscopy"},{"key":"10.1016\/j.asmart.2018.01.002_bib13","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.arthro.2005.10.008","article-title":"The Krackow stitch: a biomechanical evaluation of changing the number of loops versus the number of sutures","volume":"22","author":"McKeon","year":"2006","journal-title":"Arthroscopy"},{"key":"10.1016\/j.asmart.2018.01.002_bib14","doi-asserted-by":"crossref","first-page":"3003","DOI":"10.1177\/0363546514550989","article-title":"Biomechanical comparison of Krackow locking stitch versus nonlocking loop stitch with varying number of throws","volume":"42","author":"Hahn","year":"2014","journal-title":"Am J Sports Med"},{"key":"10.1016\/j.asmart.2018.01.002_bib15","doi-asserted-by":"crossref","first-page":"1609","DOI":"10.1016\/j.arthro.2014.06.029","article-title":"Effect of the number of suture throws on the biomechanical characteristics of the suture-tendon construct","volume":"30","author":"Hong","year":"2014","journal-title":"Arthroscopy"},{"key":"10.1016\/j.asmart.2018.01.002_bib16","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1007\/s00776-005-0929-1","article-title":"Optimum locations of the locking loop and knot in tendon sutures based on the locking Kesseler method","volume":"10","author":"Yotsumoto","year":"2005","journal-title":"J\u00a0Orthop Sci"},{"key":"10.1016\/j.asmart.2018.01.002_bib17","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1016\/j.knee.2014.02.009","article-title":"Mechanical properties of suspensory fixation devices for anterior cruciate ligament reconstruction: comparison of the fixed-length loop device versus adjustable-length loop device","author":"Eguchi","year":"2014","journal-title":"Knee"},{"key":"10.1016\/j.asmart.2018.01.002_bib18","doi-asserted-by":"crossref","first-page":"1641","DOI":"10.1177\/0363546512450406","article-title":"Biomechanical properties of porcine flexor tendon fixation with varying throws and stitch methods","volume":"40","author":"Sakaguchi","year":"2012","journal-title":"Am J Sports Med"},{"key":"10.1016\/j.asmart.2018.01.002_bib19","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1007\/s00167-013-2768-5","article-title":"Regional mechanical properties of human patellar tendon allografts","volume":"23","author":"Yanke","year":"2015","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.asmart.2018.01.002_bib20","doi-asserted-by":"crossref","first-page":"1465","DOI":"10.1007\/s00402-016-2529-2","article-title":"Evaluation of biomechanical properties: are porcine flexor tendons and bovine extensor tendons eligible surrogates for human tendons in in\u00a0vitro studies?","volume":"136","author":"Domnick","year":"2016","journal-title":"Arch Orthop Trauma Surg"}],"container-title":["Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2214687317303473?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2214687317303473?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T14:49:33Z","timestamp":1762008573000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2214687317303473"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,4]]},"references-count":20,"alternative-id":["S2214687317303473"],"URL":"https:\/\/doi.org\/10.1016\/j.asmart.2018.01.002","relation":{},"ISSN":["2214-6873"],"issn-type":[{"type":"print","value":"2214-6873"}],"subject":[],"published":{"date-parts":[[2018,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Evaluating different closed loop graft preparation technique for tibial suspensory fixation in ACL reconstruction using TightRope\u2122","name":"articletitle","label":"Article Title"},{"value":"Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.asmart.2018.01.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Asia Pacific Knee, Arthroscopy and Sports Medicine Society. Published by Elsevier (Singapore) Pte Ltd.","name":"copyright","label":"Copyright"}]}}